RSS-Feed abonnieren
DOI: 10.1055/s-0037-1608621
Use of Incisional Negative Pressure Wound Therapy in Skin-Containing Free Tissue Transfer
Publikationsverlauf
04. Juni 2017
14. September 2017
Publikationsdatum:
07. November 2017 (online)
Abstract
Background Negative pressure wound therapy (NPWT) was initially introduced for wound management, but its benefits have stimulated the investigation of its use in new clinical scenarios. Most recently, incisional NPWT has been shown to be a benefit. Incisional NPWT applied to skin-containing free tissue transfer has not been well defined. This may originate from concerns of dressing material obscuring frequent examination of the newly transferred tissue or risk of pedicle compression and potential for increased risk of tissue loss. We aim to describe incisional NPWT in cutaneous free tissue transfer.
Methods An institutional review board-approved retrospective review of consecutive free tissue transfer patients was completed over a 3-year period. Free tissue transfer procedures were performed in standard manner. After fixation of the flap to the donor site with interrupted sutures, one or two drainage tubes were inserted in the subflap position. The surface of the flap was protected with Vaseline gauze followed by a 1 cm thick layer of sterile cotton. The vacuum-assisted closure (VAC) sponge (KCI, TX) was then placed in the standard fashion and negative pressure at −125 mm Hg was initiated in a continuous mode. A window was routinely made over the flap's distal region to allow for serial flap examination. For extremity procedures, no splints were utilized, and patients were limited to motion in the hospital bed. NPWT was employed continuously for 7 days and subsequently removed along with operative drains.
Results A total of 24 consecutive patients underwent free tissue transfer. The average patient age was 39.8 years with a mean body mass index of 23. Tobacco use was noted in 58% of patients in the series. The indication for the free tissue transfer included trauma (N = 21), malignancy (N = 2), and burn reconstruction (N = 1). The areas of reconstruction included scalp (N = 5), lower extremity (N = 11), and upper extremity (N = 8). Skin-containing free flaps employed consisted of the latissimus dorsi myocutaneous free flap (N = 16), anterolateral thigh free flap (N = 6), thoracodorsal artery perforator free flap (N = 1), and radial forearm free flap (N = 1). The average defect size reconstructed was 238.3 cm2 with a mean operative time of 501 minutes. Postoperatively, patients remained in the hospital an average of 15.5 days (range: 9–32 days) with a mean follow-up of 8.1 months. No hematomas, seromas, surgical-site infections, or deep vein thrombosis/pulmonary embolism occurred in the series. None of the flaps required return to the operating room. There were no documented cases of partial or complete flap loss.
Conclusions NPWT may be employed in a fashion similar to the standard incisional application. With this technique, serial flap examination remains possible and is not associated with pedicle compression or increased rates of flap loss. Interestingly, no splints were utilized with the VAC device which itself may serve as a relative immobilizer of an extremity.
-
References
- 1 Morykwas MJ, Argenta LC, Shelton-Brown EI, McGuirt W. Vacuum-assisted closure: a new method for wound control and treatment: animal studies and basic foundation. Ann Plast Surg 1997; 38 (06) 553-562
- 2 Argenta LC, Morykwas MJ. Vacuum-assisted closure: a new method for wound control and treatment: clinical experience. Ann Plast Surg 1997; 38 (06) 563-576 , discussion 577
- 3 Blume PA, Walters J, Payne W, Ayala J, Lantis J. Comparison of negative pressure wound therapy using vacuum-assisted closure with advanced moist wound therapy in the treatment of diabetic foot ulcers: a multicenter randomized controlled trial. Diabetes Care 2008; 31 (04) 631-636
- 4 Karatepe O, Eken I, Acet E. , et al. Vacuum assisted closure improves the quality of life in patients with diabetic foot. Acta Chir Belg 2011; 111 (05) 298-302
- 5 Anghel EL, Kim PJ. Negative-pressure wound therapy: a comprehensive review of the evidence. Plast Reconstr Surg 2016; 138 (3, Suppl): 129S-137S
- 6 Salazard B, Niddam J, Ghez O, Metras D, Magalon G. Vacuum-assisted closure in the treatment of poststernotomy mediastinitis in the paediatric patient. J Plast Reconstr Aesthet Surg 2008; 61 (03) 302-305
- 7 Blackburn II JH, Boemi L, Hall WW. , et al. Negative-pressure dressings as a bolster for skin grafts. Ann Plast Surg 1998; 40 (05) 453-457
- 8 Petkar KS, Dhanraj P, Kingsly PM. , et al. A prospective randomized controlled trial comparing negative pressure dressing and conventional dressing methods on split-thickness skin grafts in burned patients. Burns 2011; 37 (06) 925-929
- 9 Eisenhardt SU, Momeni A, Iblher N. , et al. The use of the vacuum-assisted closure in microsurgical reconstruction revisited: application in the reconstruction of the posttraumatic lower extremity. J Reconstr Microsurg 2010; 26 (09) 615-622
- 10 Chariker ME, Gerstle TL, Morrison CS. An algorithmic approach to the use of gauze-based negative-pressure wound therapy as a bridge to closure in pediatric extremity trauma. Plast Reconstr Surg 2009; 123 (05) 1510-1520
- 11 Stannard JP, Volgas DA, McGwin III G. , et al. Incisional negative pressure wound therapy after high-risk lower extremity fractures. J Orthop Trauma 2012; 26 (01) 37-42
- 12 DeCarbo WT, Hyer CF. Negative-pressure wound therapy applied to high-risk surgical incisions. J Foot Ankle Surg 2010; 49 (03) 299-300
- 13 Scalise A, Calamita R, Tartaglione C. , et al. Improving wound healing and preventing surgical site complications of closed surgical incisions: a possible role of Incisional Negative Pressure Wound Therapy. A systematic review of the literature. Int Wound J 2016; 13 (06) 1260-1281
- 14 Reiss N, Schuett U, Kemper M, Bairaktaris A, Koerfer R. New method for sternal closure after vacuum-assisted therapy in deep sternal infections after cardiac surgery. Ann Thorac Surg 2007; 83 (06) 2246-2247
- 15 Lance S, Harrison L, Orbay H, Boudreault D, Pereira G, Sahar D. Assessing safety of negative-pressure wound therapy over pedicled muscle flaps: A retrospective review of gastrocnemius muscle flap. J Plast Reconstr Aesthet Surg 2016; 69 (04) 519-523
- 16 Goldstein JA, Iorio ML, Brown B, Attinger CE. The use of negative pressure wound therapy for random local flaps at the ankle region. J Foot Ankle Surg 2010; 49 (06) 513-516
- 17 Hanasono MM, Skoracki RJ. Securing skin grafts to microvascular free flaps using the vacuum-assisted closure (VAC) device. Ann Plast Surg 2007; 58 (05) 573-576
- 18 Henry SL, Weinfeld AB, Sharma SK, Kelley PK. External Doppler monitoring of free flaps through negative pressure dressings. J Reconstr Microsurg 2011; 27 (04) 215-218
- 19 Eisenhardt SU, Schmidt Y, Thiele JR. , et al. Negative pressure wound therapy reduces the ischaemia/reperfusion-associated inflammatory response in free muscle flaps. J Plast Reconstr Aesthet Surg 2012; 65 (05) 640-649
- 20 Siddiqui A, Tepper D. Muscle flap arterialization by means of negative-pressure wound therapy. Plast Reconstr Surg 2010; 125 (02) 89e
- 21 Qiu SS, Hsu CC, Hanna SA. , et al. Negative pressure wound therapy for the management of flaps with venous congestion. Microsurgery 2016; 36 (06) 467-473
- 22 Uygur F, Duman H, Ulkür E, Ceiköz B. The role of the vacuum-assisted closure therapy in the salvage of venous congestion of the free flap: case report. Int Wound J 2008; 5 (01) 50-53
- 23 Bristow PC, Perry KL, Halfacree ZJ, Lipscomb VJ. Use of vacuum-assisted closure to maintain viability of a skin flap in a dog. J Am Vet Med Assoc 2013; 243 (06) 863-868
- 24 Yu P, Yu N, Yang X, Jin X, Lu H, Qi Z. Clinical efficacy and safety of negative-pressure wound therapy on flaps: a systematic review. J Reconstr Microsurg 2017; 33 (05) 358-366
- 25 Kairinos N, Solomons M, Hudson DA. The paradox of negative pressure wound therapy--in vitro studies. J Plast Reconstr Aesthet Surg 2010; 63 (01) 174-179
- 26 Kairinos N, Solomons M, Hudson DA. Negative-pressure wound therapy I: the paradox of negative-pressure wound therapy. Plast Reconstr Surg 2009; 123 (02) 589-598 , discussion 599–600
- 27 Loveluck J, Copeland T, Hill J, Hunt A, Martin R. Biomechanical modeling of the forces applied to closed incisions during single-use negative pressure wound therapys. Eplasty 2016; 16: e20
- 28 Shen P, Blackham AU, Lewis S. , et al. Phase II randomized trial of negative-pressure wound therapy to decrease surgical site infection in patients undergoing laparotomy for gastrointestinal, pancreatic, and peritoneal surface malignancies. J Am Coll Surg 2017; 224 (04) 726-737
- 29 Acosta S, Björck M, Wanhainen A. Negative-pressure wound therapy for prevention and treatment of surgical-site infections after vascular surgery. Br J Surg 2017; 104 (02) e75-e84
- 30 Swanson EW, Cheng HT, Susarla SM, Lough DM, Kumar AR. Does negative pressure wound therapy applied to closed incisions following ventral hernia repair prevent wound complications and hernia recurrence? A systematic review and meta-analysis. Plast Surg (Oakv) 2016; 24 (02) 113-118
- 31 Karlakki SL, Hamad AK, Whittall C, Graham NM, Banerjee RD, Kuiper JH. Incisional negative pressure wound therapy dressings (iNPWTd) in routine primary hip and knee arthroplasties: A randomised controlled trial. Bone Joint Res 2016; 5 (08) 328-337
- 32 Kim DY, Park SJ, Bang SI, Mun GH, Pyon JK. Does the use of incisional negative-pressure wound therapy prevent mastectomy flap necrosis in immediate expander-based breast reconstruction?. Plast Reconstr Surg 2016; 138 (03) 558-566
- 33 Ooi AS, Song DH. Discussion: does the use of incisional negative-pressure wound therapy prevent mastectomy flap necrosis in immediate expander-based breast reconstruction?. Plast Reconstr Surg 2016; 138 (03) 567-569
- 34 Cunningham T, Marks M. Vacuum-assisted closure device and skin substitutes for complex Mohs defects. Dermatol Surg 2014; 40 (Suppl. 09) S120-S126
- 35 Kakarala K, Richmon JD, Lin DT, Deschler DG. Vacuum-assisted closure in revision free flap reconstruction. Arch Otolaryngol Head Neck Surg 2011; 137 (06) 622-624
- 36 Stannard JP, Singanamala N, Volgas DA. Fix and flap in the era of vacuum suction devices: What do we know in terms of evidence based medicine?. Injury 2010; 41 (08) 780-786
- 37 Raju A, Ooi A, Ong YS, Tan BK. Traumatic lower limb injury and microsurgical free flap reconstruction with the use of negative pressure wound therapy: is timing crucial?. J Reconstr Microsurg 2014; 30 (06) 427-430