CC BY-NC-ND 4.0 · Revista Iberoamericana de Cirugía de la Mano 2017; 45(02): 094-103
DOI: 10.1055/s-0037-1608789
Original Article | Artículo Original
Thieme Revinter Publicações Ltda Rio de Janeiro, Brazil

Utilización de los tornillos canulados sin cabeza intramedulares en el tratamiento de las fracturas de la mano - estudio anatomico en los dedos largos

Article in several languages: English | español
María Jesús Rivera Vegas
1   Medical Expert, Plastic, Aesthetic and Reconstructive Surgery Service, Hospital Universitario de Burgos, Burgos, Spain
,
Miguel Eugenio Estefanía Díez
1   Medical Expert, Plastic, Aesthetic and Reconstructive Surgery Service, Hospital Universitario de Burgos, Burgos, Spain
,
Pablo Martínez Núnez
2   Medical Resident, Plastic, Aesthetic and Reconstructive Surgery Service, Hospital Universitario de Burgos, Burgos, Spain
,
Rebeca Astorga Veganzones
2   Medical Resident, Plastic, Aesthetic and Reconstructive Surgery Service, Hospital Universitario de Burgos, Burgos, Spain
› Author Affiliations
Further Information

Publication History

12 July 2017

25 September 2017

Publication Date:
22 November 2017 (online)

Resumen

Objetivo El objetivo de este estudio es cuantificar las lesiones cartilaginosas y tendinosas que se producen al introducir tornillos canulados intramedulares percutáneos como material de osteosíntesis en fracturas de metacarpianos y falanges.

Materiales y Métodos Utilizamos en nuestro estudio anatómico piezas anatómicas donadas (7 manos) y manos no reimplantadas en nuestro hospital (1mano). Se han medido 30 metacarpianos y falanges proximales y medias. Se colocan percutáneamente los tornillos canulados de espiras completas y parciales, a través de la cabeza de los metacarpianos y las falanges proximales y medias reproduciendo las acciones realizadas en la clínica. Realizamos las mediciones: A) Porcentaje del área cartilaginosa lesionada y su localización. B) Lesión en el aparato extensor y la distancia de esta a la inserción ósea. C) Tamaño de la medular de los huesos.

Resaultados Obteniendo los siguientes resultados: A) el porcentaje del área lesionada en los metacarpianos, falanges proximales y medias es de 5,7%,13,35% y 9,62% respectivamente. B) La lesión del aparato extensor es menor de 3mm con una distancia a las inserciones óseas de 4mm y C) Obtenemos medidas de las intramedulares óseas y las relacionamos con la anchura del tornillo más adecuado.

Conclusión Como conclusión, la utilización de tornillos canulados via retrograda y percutánea es una técnica fiable en cuanto a la morbilidad asociada y damos una aproximación al tornillo más adecuado en cada localización.

 
  • References

  • 1 Cheah AE, Yao J. Hand Fractures: Indications, the Tried and True and New Innovations. J Hand Surg Am 2016; 41 (06) 712-722
  • 2 Winter M, Balaguer T, Bessière C, Carles M, Lebreton E. Surgical treatment of the boxer's fracture: transverse pinning versus intramedullary pinning. J Hand Surg Eur Vol 2007; 32 (06) 709-713
  • 3 Kim JK, Kim DJ. Antegrade intramedullary pinning versus retrograde intramedullary pinning for displaced fifth metacarpal neck fractures. Clin Orthop Relat Res 2015; 473 (05) 1747-1754
  • 4 Hornbach EE, Cohen MS. Closed reduction and percutaneous pinning of fractures of the proximal phalanx. J Hand Surg [Br] 2001; 26 (01) 45-49 (British And European Volume)
  • 5 Belsky MR, Eaton RG, Lane LB. Closed reduction and internal fixation of proximal phalangeal fractures. J Hand Surg Am 1984; 9 (05) 725-729
  • 6 Elmaraghy MW, Elmaraghy AW, Richards RS, Chinchalkar SJ, Turner R, Roth JH. Transmetacarpal intramedullary K-wire fixation of proximal phalangeal fractures. Ann Plast Surg 1998; 41 (02) 125-130
  • 7 Balaram AK, Bednar MS. Complications after the fractures of metacarpal and phalanges. Hand Clin 2010; 26 (02) 169-177
  • 8 Aita MA, Mos PA, de Paula Cardoso Marques Leite G, Alves RS, Credídio MV, da Costa EF. Minimally invasive surgical treatment for unstable fractures of the proximal phalanx: intramedullary screw. Rev Bras Ortop 2015; 51 (01) 16-23
  • 9 Giesen T, Gazzola R, Poggetti A, Giovanoli P, Calcagni M. Intramedullary headless screw fixation for fractures of the proximal and middle phalanges in the digits of the hand: a review of 31 consecutive fractures. J Hand Surg Eur Vol 2016; 41 (07) 688-694
  • 10 Doarn MC, Nydick JA, Williams BD, Garcia MJ. Retrograde headless intramedullary screw fixation for displaced fifth metacarpal neck and shaft fractures: short term results. Hand (NY) 2015; 10 (02) 314-318
  • 11 del Piñal F, Moraleda E, Rúas JS, de Piero GH, Cerezal L. Minimally invasive fixation of fractures of the phalanges and metacarpals with intramedullary cannulated headless compression screws. J Hand Surg Am 2015; 40 (04) 692-700
  • 12 Ruchelsman DE, Puri S, Feinberg-Zadek N, Leibman MI, Belsky MR. Clinical outcomes of limited-open retrograde intramedullary headless screw fixation of metacarpal fractures. J Hand Surg Am 2014; 39 (12) 2390-2395
  • 13 Boulton CL, Salzler M, Mudgal CS. Intramedullary cannulated headless screw fixation of a comminuted subcapital metacarpal fracture: case report. J Hand Surg Am 2010; 35 (08) 1260-1263
  • 14 Lazar G, Schulter-Ellis FP. Intramedullary structure of human metacarpals. J Hand Surg Am 1980; 5 (05) 477-481
  • 15 ten Berg PW, Mudgal CS, Leibman MI, Belsky MR, Ruchelsman DE. Quantitative 3-dimensional CT analyses of intramedullary headless screw fixation for metacarpal neck fractures. J Hand Surg Am 2013; 38 (02) 322-330
  • 16 Schulter-Ellis FP, Lazar GT. Internal Morphology Of Human Phalanges. J Hand Surg Am 1984; 9 (04) 477-481
  • 17 Borbas P, Dreu M, Poggetti A, Calcagni M, Giesen T. Treatment of proximal phalangeal fractures with an antegrade intramedullary screw: a cadaver study. J Hand Surg Eur Vol 2016; 41 (07) 683-687
  • 18 Shimizu T, Omokawa S, Akahane M. , et al. Predictors of the postoperative range of finger motion for comminuted periarticular metacarpal and phalangeal fractures treated with a titanium plate. Injury 2012; 43 (06) 940-945
  • 19 Pun WK, Chow SP, So YC. , et al. Unstable phalangeal fractures: treatment by A.O. screw and plate fixation. J Hand Surg Am 1991; 16 (01) 113-117
  • 20 Faruqui S, Stern PJ, Kiefhaber TR. Percutaneous pinning of fractures in the proximal third of the proximal phalanx: complications and outcomes. J Hand Surg Am 2012; 37 (07) 1342-1348
  • 21 Fujitani R, Omokawa S, Shigematsu K, Tanaka Y. Comparison of the intramedullary nail and low-profile plate for unstable metacarpal neck fractures. J Orthop Sci 2012; 17 (04) 450-456
  • 22 Facca S, Ramdhian R, Pelissier A, Diaconu M, Liverneaux P. Fifth metacarpal neck fracture fixation: Locking plate versus K-wire?. Orthop Traumatol Surg Res 2010; 96 (05) 506-512
  • 23 Yammine K, Harvey A. Antegrade intramedullary nailing for fifth metacarpal neck fractures: a systematic review and meta-analysis. Eur J Orthop Surg Traumatol 2014; 24 (03) 273-278