Thrombin generation before and after multicomponent blood collection

Thrombingeneration vor und nach Multikomponentenspende
C. Cimenti
1   Departments of Paediatrics, Medical University of Graz, Austria
,
S. Sipurzynski
2   Blood Group Serology and Transfusion Medicine, Medical University of Graz, Austria
,
S. Gallistl
1   Departments of Paediatrics, Medical University of Graz, Austria
,
A. Rosenkranz
1   Departments of Paediatrics, Medical University of Graz, Austria
,
M. Hiden
1   Departments of Paediatrics, Medical University of Graz, Austria
,
B. Leschnik
1   Departments of Paediatrics, Medical University of Graz, Austria
,
K. Schallmoser
2   Blood Group Serology and Transfusion Medicine, Medical University of Graz, Austria
,
G. Lanzer
2   Blood Group Serology and Transfusion Medicine, Medical University of Graz, Austria
,
W. E. Muntean
1   Departments of Paediatrics, Medical University of Graz, Austria
› Institutsangaben
Weitere Informationen

Publikationsverlauf

Publikationsdatum:
04. Januar 2018 (online)

Preview

Summary

IThe development of apheresis technology has increased efficiency in donor blood use by collecting specific blood components in several combinations. The question of donor safety raised by the contact of donor blood with foreign, only in part biocompatible surfaces remains. The aim of this study was to estimate the effect of multicomponent blood collection on thrombin generation performing an overall function test of coagulation. Donors, methods: 26 blood donors were included. Per apheresis two units of platelets and one unit of RBCs were collected by two cell separators (Amicus® and Trima Accel®). Each donor underwent the procedure on both apheresis systems. Samples were collected before, immediately after, and 48 hours after apheresis. Thrombin generation was measured by means of calibrated automated thrombography (CAT). Results: CATdata changed only slightly and no significant changes were seen before, immediately after, and 48 hours after apheresis. The parameters did not differ significantly between the two different apheresis devices. Conclusion: No change in parameters of continuous thrombin generation occurred, suggesting that apheresis did not lead to severe alterations in the haemostatic system.

Zusammenfassung

Moderne Zytaphereseverfahren wie die Multikomponentenspende ermöglichen durch eine vollautomatische Auftrennung des Blutes mittels Zentrifugation die gezielte Gewinnung von Zell- und/oder Plasmabestandteilen. Durch Kontakt von Spenderblut mit Fremdoberflächen sind Interaktionen wie eine Aktivierung des hämostatischen Systems denkbar. Im Rahmen unserer Studie haben wir den Einfluss der Multikomponentenspende zweier verschiedener Apheresesysteme auf Veränderungen der Thrombingeneration untersucht. Spender, Methoden: 26 Spender wurden eingeschlossen. Pro Sitzung wurden zwei Thrombozyteneinheiten und eine Erythrozyteneinheit gesammelt. Die Spender unterzogen sich der Apherese jeweils an beiden Geräten (Amicus® und Trima Accel®). Plasmaproben wurden vor Start, sofort nach Beendigung und 48 Stunden nach Apherese akquiriert. Die Messung der Thrombingeneration erfolgte mithilfe einer kalibrierten automatisierten Methode. Ergebnisse: Keine statistisch signifikante Veränderung von Parametern der Thrombingeneration vor und nach Apherese sowie keine geräteabhängigen Unterschiede. Schlussfolgerung: Multikomponentenpende scheint nicht zu relevanten Veränderungen der Thrombingeneration zu führen.