Nuklearmedizin 1976; 15(02): 80-85
DOI: 10.1055/s-0038-1624939
Originalarbeiten — Original Articles
Schattauer GmbH

Quality Control and Testing of 99mTc-Macroaggregated Albumin

Qualitätskontrolle und Prüfung von 99mTc-Albumin-Makroaggregaten
L. Darte
1   From the Departments of Radiation Physics and Hospital Pharmacy, University of Lund
,
B. R. Persson
1   From the Departments of Radiation Physics and Hospital Pharmacy, University of Lund
,
Lena Söderbom
1   From the Departments of Radiation Physics and Hospital Pharmacy, University of Lund
› Author Affiliations
Further Information

Publication History

Received:03 October 1975

Publication Date:
11 January 2018 (online)

Summary

99mTc-labelled macroaggregated albumin particles prepared from a commercial “kit” have been tested in detail. With the introduction of the method of gel chromatography column scanning it became possible to make fast and simple quantitative measurements of the radiochemical purity. This was found to be the only reliable method for quantitative determination of non-aggregated 99mTc-labelled albumin. The measuring results of the kit in question have shown a labelling efficiency of about 97—99%. In addition to a few percent of 99mTc-pertechnetate less than 0.5% of disturbing radioactivity was found. The labelling was stable for at least 5—6 h. About 80% of the particles are in the size-range of 10—80 μm. A rough estimation of the number of particles in the solution resulted in 0.4 · 106 per mg of MAA.

The dynamic studies of the lung uptake and the elimination of 99mTc-MAA in man resulted in a biological half-time in the lungs of about 1—2 h. The radiation absorbed dose to the lungs per mCi administered 99mTc-MAA was estimated to 0.1 rad. Less than 1% of the radioactivity was accumulated in liver, spleen or kidneys during the first 25 minutes after injection.

99mTc-markierte Albumin-Makroaggregatpartikel, die aus einem „Kit“ hergestellt wurden, sind im Detail geprüft worden. Mit der Methode Gelchromatographie Säulen Scanning ist es möglich, schnelle und einfache quantitative Messungen der radiochemischen Reinheit durchzuführen. Die Markierungs-Effektivität dieses Kits ist ungefähr 97—99 %. Außer einigen Prozenten des 99mTc-Pertechnetates wurde weniger als 0,5% von anderen radioaktiven Bestandteilen als Makroaggregat gefunden. Die Markierung war länger als 5—6 Stunden stabil. Ungefähr 80% der Partikel hatten eine Größe von 10—80 μm. Eine ungefähre Schätzung der Anzahl der Partikel in der Suspension ergab 0,5 · 106 per mg MAA. Dynamische Untersuchungen der Aufnahme und Eliminierung von 99mTc-MAA in den Lungen ergaben eine biologische Halbwertzeit in den Lungen von ungefähr 1—2 Stunden. Die Strahlenbelastung der Lungen beträgt 0,1 rad per mCi verabreichten 99mTc-MAA. Weniger als 1% der verabreichten Radioaktivität wurde in der Leber, Milz oder in den Nieren während der ersten 25 Minuten nach der Injektion kumuliert.

 
  • References

  • 1 Wagner Jr. H. N, Sabiston D. C, McAffee J. G, Tow D, Stern H. S. Diagnosis of massive embolism in man by radioisotope scanning. New Engl. J. Med 1964; 271: 377.
  • 2 Taplin G. V, Johnson D. E, Dore K, Kaplan H. S. Suspensions of radioalbumin aggregates for photoscanning the liver, spleen, lung, and other organs. J. Nucl. Med 1964; 5: 259.
  • 3 Bowen B. M, Wood D. E. Preparation of technetium-99m human serum albumin macroaggregates. Amer. J. Hosp. Pharmacy 1969; 26: 529.
  • 4 Davis M. A. 99mTc-iron hydroxide aggregates. Evaluation of a new lung scanning agent. Radiology 1970; 95: 347.
  • 5 Ficken V, Halpern S, Smith C, Miller L, Bogardus C. 99mTc-sulphur colloid macroaggregates. Radiology 1970; 97: 289.
  • 6 Gwyter M. M, Field E. O. Aggregated 99mTc-labelled albumin for lung scintiscanning. Int. J. Appl. Radiat. Isotopes 1966; 17: 485.
  • 7 Wagner Jr. H. N, Rhodes B. A, Sasaki Y, Ryan J. P. Studies of the circulation with radioactive microspheres. Invest. Radiol 1969; 4: 374.
  • 8 Hultman U. Personal communication. AB Atomenergi: Studsvik, Sweden; 1974
  • 9 Persson R. B. R, Strand S. E. Labelling processes and short-term biodynamical behaviour of different types of 99mTc-labelled complexes. In Radiopharmaceuticals and labelled compounds. Vol, I Vienna, IAEA: 1973: 169.
  • 10 Persson R. B. R. Gel-Chromatography-Column-Scanning (“GCS“). A method for identification and quality control of technetium-99m radiopharmaceuticals. In Proc. Int. Symp. Radiopharmaceuticals, 1974. Atlanta, Ga., U.S.A. Soc. Nucl. Med: N. Y. (U.S.A.); 1975: 228.
  • 11 Persson R. B. R, Darte L. Gel chromatography column scanning for the analysis of 99mTc-labelled compounds. J. Chrom 1974; 101: 315-326.
  • 12 Persson R. B. R, Strand S. E, Svensson L. BIODYN: A Computer Scintillation Camera System for Comparative Dynamic Studies in Biomedical Testing and Use of Radiopharmaceuticals. To be published.
  • 13 Taplin G. V, Johnson D. E, Kennedy J. C, Dore E. K, Poe N. D, Swanson L. A, Greenberg A. Aggregated albumin labelled with various radioisotopes. In Radioactive Pharmaceuticals. Editors Andrews G. A, Knisely R. M, Wagner Jr H. N, Anderson E. B. (U.S.A.): U.S. Atomic Energy Commission; 1966: 525.
  • 14 Honda T, Kazem I, Croll M. N, Brady L. W. Instant labelling of macro- and microaggregated albumin with 99mTc. J. Nucl. Med 1970; 11: 580.
  • 15 Brownell G. L, Ellett W. H, Reddy A. R. Absorbed fractions for photon dosimetry. M I R D Pamphlet No. 3. J. Nucl. Med 1968; 9: 27.
  • 16 Dillman L. T. Radionuclide decay schemes and nuclear parameters for use in radiation dose estimation. MIRD Pamphlet No. 4. J. Nucl. Med 1969; 10: 5.
  • 17 Loevinger R, Berman M. A schema for absorbeddose calculations for biologically distributed radionuclides. M I R D Pamhlet No. 1. J. Nucl. Med 1968; 9: 7.
  • 18 Snyder W. S, Fisher Jr. H. L, Mar Ford R, Warner G. G. Estimates of absorbed fractions for monoenergetic photon sources uniformly distributed in various organs of a heterogeneous phantom. MIRD Pamphlet No. 5. J. Nucl. Med 1969; 10: 5.