Subscribe to RSS
DOI: 10.1055/s-0038-1633234
In Vitro Strain Patterns of the Intact Equine Metacarpus and Metatarsus Following Plate Luting
Publication History
Received for publication
10 December 1989
Publication Date:
10 February 2018 (online)

Summary
With internal fixation of fractures using a plate and screws, the stability of the fixation is achieved mainly by the force generated by either lag screws or plate screws. The plate protects the bone from overload. The important mechanism in the function of plate fixation is the friction between the undersurface of the plate and the bone surface. It has become evident that plate luting, i. e. interposition of a bone cement layer between the plate and the bone, will alter the transmission of expected forces due to improved contact between the plate and the bone. The purpose of this project was to evaluate the load/strain relationships that occurred following plate luting and to understand why this procedure improved the mechanical behaviour of plate fixation in equine bone. We measured the strain patterns that occurred in unplated, plated and luted equine third metacarpal and metatarsal bones under simulated physiological conditions. Plate application resulted in reduced strain under the plate and increased strain at the opposite cortex. Following plate luting, this effect was more pronounced. Hysteresis between the loading-unloading cycle was less pronounced in the luted plates. This indicated that plate luting increased the effect of strain protection.
Plate luting was shown to reduce the strain under the plate and to increase it in the transcortex, effectively increasing the effect of strain protection.
-
References
- 1 Turner A S, Mills E J, Gabel A A. In vivo measurement of bone strain in the horse. Am J Vet Res 1975; 36: 1573-80.
- 2 Biewener A A, Thomason J, Lanyon L E. Mechanics of locomotion and jumping in the forelimb of the horse (Equus); In vivo stress developed in the radius and the metacarpus. J Zool 1983; 201: 67-82.
- 3 Nunamaker D M, Butterweck D M, Black J. Fatigue fractures in racehorses: Relationships with age and strain. Trans 33rd Ortho Res Soc 1987; 72.
- 4 Biewener A A, Thomason J, Goodship A, Lanyon L E. Bone stress in the horse forelimb during locomotion at different gaits: A comparison of two different experimental methods. J Biomech 1983; 16: 565-76.
- 5 Nunamaker D M, Richardson D W, Butterweck D M. Mechanical effects of plate luting. Trans 34th Annual Meeting Ortho Res Soc.. Atlanta: 1988: 305.
- 6 Nunamaker D M, Bowman K F, Richardson D W, Herring M. Plate luting: A preliminary report of its use in horses. Vet Surg 1986; 15: 289-93.
- 7 Nunamaker D M. Unpublished data. 1988
- 8 Young D R, Richardson D W, Nunamaker D M, Ross M W, Tulleners E P. Use of dynamic compression plating for treatment of diaphyseal tibial fractures in foals: Nine cases (1980–1987). J Am Vet Med Assoc 1989; 194: 1755-60.
- 9 Roush J K, Wilson J W. Effect of plate luting on cortical vascularity and development of cortical porosity. Vet Surg 1989; 18: 61.
- 10 Fackleman G E, Nunamaker D M. Manual of Internal Fixation in the Horse. Berlin, Heidelberg, New York: Springer; 1982
- 11 Bramlage L R. Long bone fractures. Symposium on Equine Orthopedics. Vet Clin North Am 1983; 5: 285.
- 12 Cordey J R, Gautier E, Sumner-Smith G, Perren S M. Utilisation des jauges électriques d’extensométrie “in vivo” en biomécanique. In: Biomécanique 86. Rumelhart (ed). Paris: GAMAC; 1986: 59-66.
- 13 Meyrueis J P, Bonnet G, Yimmermann R, de Bazellaire E. Ostéosynthèse par plaques adhérentes. Etude physique expérimentale. Rev Chir Orthop 1977; 63: 627-34.
- 14 Pillar R M. Powder metal made orthopaedic implants with porous surface for fixation by tissue ingrowth. J Biomed Mater Res 1979; 13: 799-810.
- 15 Rybicki E F, Simonen F A, Mills E J, Hassler C R, Milne DW, Weis E B. Mathematical and experimental studies of the mechanics of plated transverse fractures. J Biomech 1974; 7: 377-84.
- 16 Cordey J R, Perren S M. Analysis of strain distribution in bone after plating. Size effects. In: Second International Symposium on Internal Fixation of Fractures. Moyen B. (ed). Lyon: Facult de Medecine Alexis Carrel; 1982: 46-61.
- 17 Cordey J R, Perren S M. Limits of plate on bone friction in internal fixation of fractures. Trans 31st Annual Meeting Ortho Res Soc 1985; 186.