Thromb Haemost 1991; 65(05): 608-617
DOI: 10.1055/s-0038-1648198
Original Article
Schattauer GmbH Stuttgart

Baboon Fibrinogen Adsorption and Platelet Adhesion to Polymeric Materials

Joseph A Chinn
The Department of Chemical Engineering and Center for Bioengineering, BF-10, University of Washington, Seattle, Washington, USA
,
Thomas A Horbett
The Department of Chemical Engineering and Center for Bioengineering, BF-10, University of Washington, Seattle, Washington, USA
,
Buddy D Ratner
The Department of Chemical Engineering and Center for Bioengineering, BF-10, University of Washington, Seattle, Washington, USA
› Institutsangaben
Weitere Informationen

Publikationsverlauf

Received 06. Oktober 1989

Accepted after revision 22. Januar 1991

Publikationsdatum:
24. Juli 2018 (online)

Summary

The role of fibrinogen in mediating platelet adhesion to polymers exposed to blood plasma was studied by comparison of the effect of plasma dilution on fibrinogen adsorption and platelet adhesion, and by the use of coagulation factor deficient plasmas. Polyetherurethane substrates were first preadsorbed with dilute plasma, then contacted with washed platelets suspended in a modified, apyrase containing Tyrode’s buffer. Platelet adhesion was studied under static conditions in Multiwell dishes, and also under shearing conditions using a parallel plate perfusion chamber. Fibrinogen adsorption and platelet adhesion were measured using 125I radiolabeled baboon fibrinogen and min radiolabeled baboon platelets, respectively. Surfaces were characterized by electron spectroscopy for chemical analysis (ESCA).

When fibrinogen adsorption to Biomer was measured after 2 h contact with a series of dilute plasma solutions under static conditions, a peak in adsorption was observed from 0.26% plasma, i.e., adsorption was greater from 0.26% plasma than from either more or less dilute plasma. A peak in subsequent platelet adhesion to the plasma preadsorbed surfaces, measured after 2 h static incubation with washed platelets, was also observed but occurred on Biomer preadsorbed with 1.0% plasma.

When fibrinogen adsorption was measured after 5 min contact under shearing conditions, the fibrinogen adsorption peak occurred on surfaces that had been exposed to 1.0% plasma. A peak in platelet adhesion to these preadsorbed surfaces, measured after 5 min contact with the platelet suspensions under shearing conditions, was observed on Biomer preadsorbed with 0.1% plasma. Shifts between the positions of the peaks in protein adsorption and platelet adhesion occurred on other polymers tested as well.

Platelet adhesion was almost completely inhibited when baboon and human plasmas lacking fibrinogen (i. e., serum, heat defibrinogenated plasma, and congenitally afibrinogénémie plasma) were used. Platelet adhesion was restored to near normal when exogenous fibrinogen was added to fibrinogen deficient plasmas. Adhesion was also inhibited completely when a monoclonal antibody directed against the glycoprotein IIb/IIIa complex was added to the platelet suspension. Platelet adhesion to surfaces preadsorbed to von Willebrand factor deficient plasma was the same as to surfaces preadsorbed with normal plasma.

While it appears that surface bound fibrinogen does mediate the initial attachment of platelets to Biomer, the observation that the fibrinogen adsorption and platelet adhesion maxima do not coincide exactly also suggests that the degree of subsequent platelet adhesion is dictated not only by the amount of surface bound fibrinogen but also by its conformation.

 
  • References

  • 1 Young BR, Lambrecht LK, Cooper SL, Mosher DF. Plasma proteins: their role in initiating platelet and fibrin deposition on biomaterials. In: Biomaterials: Interfacial Phenomena and Applications Cooper SL, Peppas NA. (eds) ACS Advances in Chemistry Series; Washington, DC: 1982. 199 317-350
  • 2 Horbett TA. Protein adsorption on biomaterials. In: Biomaterials: Interfacial Phenomena and Applications Cooper SL, Peppas NA. (eds) ACS Advances in Chemistry Series; Washington, DC: 1982. 199: 233-244
  • 3 Baier RE, Dutton RC. Initial events in interactions of blood with a foreign surface. J Biomed Mater Res 1969; 3: 191-206
  • 4 Vroman L, Adams AL. Identification of rapid changes at plasma-solid interfaces. J Biomed Mater Res 1969; 3: 43-67
  • 5 Slack SM, Horbett TA. Physicochemical and biochemical aspects of fibrinogen adsorption from plasma and binary protein solutions onto polyethylene and glass. J Coll Interf Sci 1988; 124: 535-551
  • 6 Vroman L, Adams AL, Fischer GC, Munoz PC, Stanford M. Proteins, plasma, and blood in narrow spaces of clot-promoting surfaces. In: Biomaterials: Interfacial Phenomena and Applications Cooper SL, Peppas NA. (eds) ACS Advances in Chemistry Series; Washington, DC: 1982. 199 265-276
  • 7 Horbett TA. Mass action effects on competitive adsorption of fibrinogen from hemoglobin solutions and from plasma. Thromb Haemostas 1984; 51: 174-181
  • 8 Slack SM, Horbett TA. Changes in the strength of fibrinogen attachment to solid surfaces: an explanation of the influence of surface chemistry on the Vroman effect. J Coll Interf Sci 1989; 133: 148-165
  • 9 Brash JL, ten Hove P. Effect of plasma dilution on adsorption of fibrinogen to solid surfaces. Thromb Haemostas 1984; 51: 326-330
  • 10 Zucker MB, Vroman L. Platelet adhesion induced by fibrinogen adsorbed onto glass. Proc Soc Exp Biol Med 1969; 131: 318-320
  • 11 Poot A, Beugeling T, Cazenave JP, Bantjes A, van Aken WG. Platelet deposition in a capillary perfusion model: quantitative and morphological aspects. Biomaterials 1988; 9: 126-132
  • 12 Adams GA, Feuerstein IA. Visual fluorescent and radio-isotopic evaluation of platelet accumulation and embolization. Trans Am Soc Artif Int Organs 1980; 26: 17-23
  • 13 Kim SW, Lee ES. The role of adsorbed proteins in platelet adhesion to polymer surfaces. J Polym Sci: Polym Symp 1976; 66: 429-441
  • 14 Lindon JN, McManama G, Kushner L, Merrill EW, Salzman EW. Does the conformation of adsorbed fibrinogen dictate platelet interactions with artificial surfaces. Blood 1986; 68: 355-362
  • 15 Harker LA, Hanson SR. Experimental arterial thromboembolism in baboons. Mechanism, quantitation, and pharmacologic prevention. J Clin Invest 1979; 64: 559-569
  • 16 Houdijk WPM, de Groot PG, Nievelstein PFEM, Sakariassen KS, Sixma JJ. Subendothelial proteins and platelet adhesion: von Willebrand factor and fibronectin, not thrombospondin, are involved in platelet adhesion to extracellular matrix of human vascular endothelial cells. Arteriosclerosis 1986; 6: 24-33
  • 17 Horbett TA, Counts RB. Von Willebrand Factor/Factor VIII adsorption to surfaces from human plasma. Thromb Res 1984; 36: 599-608
  • 18 Lambrect LK, Young BR, Stafford RE, Park K, Albrecht RM, Mosher DF, Cooper SL. The influence of preadsorbed canine von Willebrand factor, fibronectin and fibrinogen on ex vivo artificial surface-induced thrombosis. Thromb Res 1986; 41: 99-117
  • 19 Hearn MJ, Ratner BD, Briggs D. SIMS and XPS studies of polyurethane surfaces. 1. Preliminary studies. Macromolecules 1988; 21: 2950-2959
  • 20 Edelman PG, Ratner BD. Surface properties of polyurethanes with C{-18} pendant groups attached to the hard segments by two different routes. ACS Polym Mater Sci Eng 1988; 59: 253-257
  • 21 Ratner BD, McElroy BJ. Electron spectroscopy for chemical analysis: applications in the biomedical sciences. In: Spectroscopy in the Biomedical Sciences Gendreau RM. (ed) CRC Press; Boca Raton, FL: 1986. p 107
  • 22 Kotze HF, Lotter MG, Badenhorst PN, Heyns ADP. Kinetics of In-111-platelets in the baboon: I. isolation and labelling of a viable and representative platelet population. Thromb Haemostas 1985; 53: 404-407
  • 23 Dewanjee MK, Rao SA, Disdisheim P. Indium-111 tropolone, a new high-affinity platelet label: Preparation and evaluation of labelling parameters. J Nucl Med 1981; 22: 981-987
  • 24 Weathersby PK, Horbett TA, Hoffman AS. Solution stability of bovine fibrinogen. Thromb Res 1977; 10: 245-252
  • 25 Horbett TA. Adsorption of proteins from plasma to a series of hydrophilic-hydrophobic copolymers. 2. Compositional analysis with the prelabeled protein technique. J Biomed Mater Res 1981; 15: 673-695
  • 26 Ratnoff OD, Menzie C. A new method for the determination of fibrinogen in small samples of plasma. J Lab Clin Med 1951; 37: 316-320
  • 27 Mohammad SF, Kolff WJ, Olsen DB. Effect of polymeric albumin-IgG on blood-material interaction. Trans Am Soc Artif Int Organs 1987; 23: 588-591
  • 28 Loeb WF, MacKey BE. A “cuvette method” for the determination of plasma fibrinogen. Bull Am Soc Vet Clin Pathol 1972; 1: 5-8
  • 29 Torem S, Schneider PA, Hanson SR. Monoclonal antibody-induced inhibition of platelet function: Effects on hemostasis and vascular graft thrombosis in baboons. J Vase Surg 1988; 7: 172-180
  • 30 Sakariassen KS, Aarts PAMM, de Groot PG, Houdijk WPM, Sixma JJ. A perfusion chamber developed to investigate platelet interaction in flowing blood with human vessel wall cells, their extracellular matrix, and purified components. J Lab Clin Med 1983; 102: 522-535
  • 31 Feuerstein IA, Kush J. Platelet adherence and detachment - in what ways is surface-bound albumin different from surface-bound fibrinogen?. Thromb Haemostas 1986; 55: 184-188
  • 32 Tyler BJ, Castner DG, Ratner BD. Regularization: A stable and accurate method for generating depth profiles from angle dependent XPS data. Surf Interface Anal 1989; 14: 443-450
  • 33 Brash JL, Uniyal S. Dependence of albumin-fibrinogen simple and competitive adsorption on surface properties of biomaterials. J Polym Sci 1979; 66: 377-389
  • 34 Chinn JA, Posso SE, Horbett TA, Ratner BD. Post-adsorptive transitions in fibrinogen adsorbed to Biomer: Changes in baboon platelet adhesion, antibody binding, and sodium dodecyl sulfate elutability. J Biomed Mater Res, in press
  • 35 Rapoza RJ, Horbett TA. Changes in the SDS elutability of fibrinogen adsorbed from plasma to polymers. J Biomater Sci: Polymer Edition 1989; 1: 99-110
  • 36 Bohnert JL, Horbett TA. Changes in adsorbed fibrinogen and albumin interactions with polymers indicated by decreases in detergent elutability. J Coll Interf Sci 1986; 111: 363-377
  • 37 Packham MA, Evans G, Glynn MF, Mustard JF. The effect of plasma proteins on the interaction of platelets with glass surfaces. J Lab Clin Med 1969; 73: 686-696
  • 38 Salzman EW, Lindon J, Brier D, Merrill EW. Surface-induced platelet adhesion, aggregation, and release. Ann NY Acad Sci 1977; 283: 114-127
  • 39 Sakariassen KS, Bolhuis PA, Sixma JJ. Platelet adherence to subendothelium of human arteries in pulsatile and steady flow. Thromb Res 1980; 19: 547-559
  • 40 Chinn JA, Ratner BD, Horbett TA. The adsorption of baboon fibrinogen and adhesion of platelets to a thin film polymer deposited by radio-frequency glow discharge of allylamine. Biomaterials, in press
  • 41 Slack SM, Bohnert JL, Horbett TA. The effects of surface chemistry and coagulation factors on fibrinogen adsorption from plasma. Ann NY Acad Sci 1987; 516: 223-243
  • 42 Feuerstein IA, Ratner BD. Adhesion and aggregation of thrombin prestimulated human platelets: Evaluation of a series of biomaterials characterized by ESC A. Biomaterials 1990; 11: 127-132
  • 43 Grasel TG, Pierce JA, Cooper SL. Effects of alkyl grafting on surface properties and blood compatibility of polyurethane block copolymers. J Biomed Mater Res 1987; 21: 815-842
  • 44 Lelah MD, Lambrecht LK, Young BR, Cooper SL. Physiochemical characterization and in vivo blood tolerability of cast and extruded Biomer. J Biomed Mater Res 1983; 17: 1-22
  • 45 Hoffman AS, Horbett TA, Ratner BD, Hanson SR, Harker LA, Reynolds LO. Thrombotic events on grafted polyacrylamide-Silastic surfaces as studied in a baboon. In: Biomaterials: Interfacial Phenomena and Applications Cooper SL, Peppas NA. (eds) ACS Advances in Chemistry Series; Washington, DC: 1982. 199 59-80
  • 46 Hanson SR, Harker LA, Ratner BD, Hoffman AS. In vivo evaluation of artificial surfaces with a nonhuman primate model of arterial thrombosis. J Lab Clin Med 1980; 95: 289-304
  • 47 French JE. In: Thrombosis. The Fine Structure of Experimental Thrombi Sherry S, Brinkhous KM, Genton E, Stengle JM. (eds) Natl Acad Sci; Washington, DC: 1969. p 300
  • 48 Turitto VT. Blood viscosity, mass transport, and thrombogenesis. In: Progress in Haemostasis and Thrombosis Spaet TH. (ed) Grune & Stratton; New York: 1982. 6 139-177
  • 49 Sakariassen KS, Joss R, Muggli R, Kuhn H, Tschopp TB, Sage H, Baumgartner HR. Collagen type III induced ex vivo thrombogenesis in humans. Arteriosclerosis 1990; 10: 276-284