Thromb Haemost 1994; 72(05): 652-658
DOI: 10.1055/s-0038-1648936
Review Article
Schattauer GmbH Stuttgart

Factors Influencing the Reported Sensitivity and Specificity of Impedance Plethysmography for Proximal Deep Vein Thrombosis

Clive Kearon
The McMaster University and McMaster Medical Unit, Hamilton Civic Hospitals Research Center, Hamilton, Ontario, Canada
,
Jack Hirsh
The McMaster University and McMaster Medical Unit, Hamilton Civic Hospitals Research Center, Hamilton, Ontario, Canada
› Author Affiliations
Further Information

Publication History

Received 11 April 1994

Accepted 13 June 1994

Publication Date:
06 July 2018 (online)

Summary

A number of recent studies have found a considerably lower sensitivity of the IPG for proximal DVT than originally reported. We reviewed the literature to try and identify reasons for the between study differences in sensitivity and specificity of the IPG for proximal DVT. A number of biases were identified which may have inflated the sensitivity reported by some earlier studies including: repeated IPG testing prior to venography; inclusion of data from patients used to derive the IPG discriminant line in the final calculation of sensitivity; and inclusion of patients with a known abnormal IPG in the study population. In addition, there is emerging evidence that, at least in some centers, the sensitivity of the IPG may have decreased due to a shift in the spectrum of proximal DVTs to smaller clots. Furthermore, rates of conversion during serial follow-up are considerably higher for IPG than for venous ultrasound, suggesting that IPG conversion is often due to extension of small missed proximal DVTs rather than just extension of calf vein clots. As the smaller proximal DVTs which IPG is prone to miss are likely to be clinically less important than more extensive clots, it is unclear whether the recently reported drop in sensitivity of the IPG places patients at increased risk. IPG users need to be aware of its limitations, and we recommend that additional testing is performed in patients with a high clinical suspicion of DVT who have a normal IPG, as the negative predictive value of IPG may be unacceptable in these circumstances.

 
  • References

  • 1 Kakkar VV, Howe CT, Flanc C, Clarke MB. Natural history of postoperative deep-vein thrombosis. Lancet 1969; 230-232
  • 2 Moser KM, LeMoine JR. Is embolic risk conditioned by location of deep venous thrombosis. Ann Intern Med 1981; 94: 439-444
  • 3 Wheeler HB, O’Donnell JA, Anderson FA, Benedict Jr K. Occlusive impedance phlebography: A diagnostic procedure for venous thrombosis and pulmonary embolism. Prog Cardiovasc Dis 1974; 17: 199-205
  • 4 Hull RD, Van Aken WG, Hirsh J, Gallus AS, Hoicka G. et al Impedance plethysmography using the occlusive cuff technique in the diagnosis of venous thrombosis. Circulation 1976; 53: 696-700
  • 5 Hull RD, Hirsh J, Carter Jay R, Ockelford P, Buller H, Turpie AGG, Powers P, Kinch D, Dodd P, Gill J, Leclerc J, Gent M. Diagnostic efficacy of impedance plethysmography for clinically-suspected deep-vein thrombosis. Ann Intern Med 1985; 102: 21-28
  • 6 Huisman MV, Buller HR, ten Cate JW, Vreeken J. Serial impedance plethysmography for suspected deep venous thrombosis in outpatients. The Amsterdam General Practitioner Study. N Engl J Med 1986; 314: 823-828
  • 7 Huisman MV, Buller HR, ten Cate JW, Heijermans HSF, van der Laan J, van Maanen DJ. Management of clinically suspected acute venous thrombosis in outpatients with serial impedance plethysmography in a community hospital setting. Arch Intern Med 1989; 149: 511-513
  • 8 Anderson DR, Lensing AWA, Wells PS, Levine MN, Weitz JI, Hirsh J. Limitations of impedance plethysmography in the diagnosis of clinically suspected deep-vein thrombosis. Ann Intern Med 1993; 118: 25-30
  • 9 Prandoni P, Lensing AWA, Buller HR, Carta M, Vigo M, Cogo A, Cuppini S, ten Cate JW. Failure of computerized impedance plethysmography in the diagnostic management of patients with clinically suspected deep-vein thrombosis. Thromb Haemost 1991; 65 (03) 233-236
  • 10 Hull R, Hirsh J, Sackett DL, Powers P, Turpie AGG, Walker I. Combined use of leg scanning and impedance plethysmography in suspected venous thrombosis. An alternative to venography. N Engl J Med 1977; 296: 1497-1500
  • 11 Toy PTCY, Schrier SL. Occlusive impedance plethysmography. A nonin-vasive method of diagnosis of proximal deep vein thrombosis. West J Med 1978; 129: 89-93
  • 12 Flanigan DP, Goodreau JJ, Burham SJ, Bergan JJ, Yao JST. Vascular-laboratory diagnosis of clinically suspected acute deep-vein thrombosis. Lancet 1978; 331-334
  • 13 Hull R, Taylor DW, Hirsh J, Sackett DL, Powers P. et al Impedance plethysmography: the relationship between venous filling and sensitivity and specificity for proximal vein thrombosis. Circulation 1978; 58 (05) 898-902
  • 14 Hull R, Hirsh J, Sackett DL, Taylor DW, Carter C, Turpie AGG, Zielinsky A, Powers P, Gent M. Replacement of venography in suspected venous thrombosis by impedence plethysmography and 125I-fibrinogen leg scanning. Ann Intern Med 1981; 94: 12-15
  • 15 Peters HS, Jonker JJ, de Boer AC, den Ottolander GJ. Home-diagnosis of deep venous thrombosis with impedance plethysmography. Thromb Haemost 1982; 48: 297-300
  • 16 Prandoni P, Lensing AWA, Huisman MV, Jonker JJC, Vigo M, Borm JJJ, Buller HR, Sing AK, Carta M, Wouter ten Cate J. A new computerized impedance plethysmograph: accuracy in the detection of proximal deep-vein thrombosis in symptomatic outpatients. Thromb Haemost 1991; 65: 229-232
  • 17 Heijboer H, Cogo A, Buller HR, Prandoni P, ten Cate JW. Detection of deep vein thrombosis with impedance plethysmography and real-time compression ultrasonography in hospitalized patients. Arch Intern Med 1992; 152: 1901-1903
  • 18 Agnelli G, Longetti M, Cosmi B, Lupattelli L, Barzi F, Levi M, Nenci GG. Diagnostic accuracy of computerized impedence plethysmography in the diagnosis of symptomatic deep vein thrombosis: A controlled venographic study. Angiology 1990; 41: 559-564
  • 19 Wells PS, Hirsh J, Anderson DR, Lensing AWA, Foster G, Kearon MC, Weitz J, Cogo A, Prandoni P, Minuk T, Thompson G, Beneditti L, Girolami A. Comparison of the accuracy of impedance plethysmography and compression ultrasonography in outpatients with clinically suspected deep vein thrombosis. 1994 Submitted for publication
  • 20 Ginsberg JS, Wells PS, Hirsh J, Panju AA, Patel A, Malone DE, McGinnis J, Stevens P, Brill-Edwards P. Reevaluation of the sensitivity of impedence plethysmography for the detection of proximal deep vein thrombosis. Arch Intern Med 1994 in press
  • 21 Sackett DL, Haynes RB, Tugwell P. The selection of diagnostic tests. In: Clinical Epidemiology A Basic Science for Clinical Medicine. Boston/Toronto: Little Brown and Company; 1985: 47-57
  • 22 Agnelli G, Cosmi B, Radicchia S, Veschi F, Boschetti E, Lupattelli L, Rinonapoli E, Nenci GG. Features of thrombi and diagnostic accuracy of impedance plethysmography in symptomatic and asymptomatic deep vein thrombosis. Thromb Haemost 1993; 70: 266-269
  • 23 Cogo A, Prandoni P, Bemardi E, Polistena P, Villalta S, Simioni P, Girolami A. Distribution of proximal-vein thrombi in symptomatic patients: diagnostic implications. Thrombosis and Haemostasis 1993; 69 (06) Abst 271-619
  • 24 Cruickshank MK, Levine MN, Hirsh J, Turpie AGG, Powers P, Jay R, Gent M. An evaluation of impedance plethysmography and 125I-fibrinogen leg scanning in patients following hip surgery. Thromb Haemost 1989; 62: 830-834
  • 25 Sluzewski M, Koopman MMW, Schuur KH, van Vroonhoven ThJMV, Ruijs JHJ. Influence of negative ultrasound findings on the management of in- and outpatients with suspected deep-vein thrombosis. Eur J Radiol 1991; 13: 174-177
  • 26 Heijboer H, Buller HR, Lensing AWA, Turpie AGG, Colly LP, ten Cate WJ. A comparison of real-time compression ultrasonography with impedance plethysmography for the diagnosis of deep-vein thrombosis in symptomatic outpatients. N Engl J Med 1993; 329: 1365-1369
  • 27 Wheeler HB, Anderson FA. Impedance Plethysmography and DVT Diagnosis. Ann Intern Med 1993; 119: 246
  • 28 Marantz PR, Dresner A. Impedance Plethysmography and DVT Diagnosis. Ann Intern Med 1993; 119: 246
  • 29 Carter CJ. Impedance Plethysmography and DVT Diagnosis. Ann Intern Med 1993; 119: 246-247
  • 30 Raskob GE, Pineo GF, Hull RD. Impedance Plethysmography and DVT Diagnosis. Ann Intern Med 1993; 119: 247
  • 31 Anderson DR, Lensing A, Hirsh J. Impedance Plethysmography and DVT Diagnosis. Ann Intern Med 1993; 119: 247
  • 32 Bounameaux H. Noninvasive diagnosis of deep venous thrombosis: lesson from the debate about computerized impedance plethysmography. Thromb Haemost 1992; 68: 89
  • 33 Wells PS, Anderson DR, Kearon MC, Weitz JI, Hirsh J. The combination of pretest clinical likelihood (PCL) and non-invasive tests improves management of outpatients with suspected deep vein thrombosis (DVT). Thromb Haemost 1993 69. 06 Abst 1916 1080