Thromb Haemost 1984; 51(01): 009-011
DOI: 10.1055/s-0038-1660997
Original Article
Schattauer GmbH Stuttgart

Antithrombin III Determination by Rate (Kinetic) Nephelometry

G Balla
The Pediatric Clinic (Dir. Prof. L. Karmazsin), University Medical School, Debrecen, Hungary
,
M Misz
1   The Second Internal Clinic (Dir. Prof. K. Rak), University Medical School, Debrecen, Hungary
,
L Karmazsin
The Pediatric Clinic (Dir. Prof. L. Karmazsin), University Medical School, Debrecen, Hungary
,
K Rák
The Pediatric Clinic (Dir. Prof. L. Karmazsin), University Medical School, Debrecen, Hungary
› Institutsangaben
Weitere Informationen

Publikationsverlauf

Received 12. Oktober 1982

Accepted 31. Oktober 1983

Publikationsdatum:
19. Juli 2018 (online)

Summary

Rate nephelometry immunological antithrombin III determination was elaborated with Beckman Immunochemistry System. The measuring can be carried out within 60 sec from 20 μl plasma. The results show a close correlation with those of gained by the radial immunodiffusion method (r = 0.91) and by Coatest (Kabi-Ortho) (r = 0.77). Both laser-nephelometric and usual non-nephelometric anti-antithrombin III serum (Behring) may be applied.

 
  • References

  • 1 Bick RL. Clinical relevance of anti thrombin III. Semin Thromb Haemostas 1982; 8: 276-287
  • 2 Fareed J, Messmore HL, Walenga JM, Bermes EW, Bick RL. Laboratory evaluation of antithrombin III: A critical overview of currently available methods for antithrombin III measurements. Semin Thromb Haemostas 1982; 8: 288-301
  • 3 Fareed J, Messmore HL, Walenga JM, Bermes Jr EW. Diagnostic efficacy of newer synthetic-substrates methods for assessing coagulation variables: A critical overview. Clin Chem 1983; 29: 225-236
  • 4 Mancini G, Carbonara AO, Hermans JF. Immunochemical quantitation of antigens by single radial immundiffusion. Int J Immunochem 1965; 2: 235-243
  • 5 Messmore HL. Natural inhibitors of the coagulation system. Semin Thromb Haemostas 1982; 8: 267-275
  • 6 Parvez Z, Fareed J, Messmore HL, Bermes EW. Laser and rate nephelometric methods for the quantitation of coagulation proteins. In: Seminar on Biochemical Hematology. Sunderman FW. (Ed.) Association of Clinical Scientists; Philadelphia: 1979. p 404
  • 7 Parvez Z, Fareed J, Messmore HL, Moncada R. Laser nephelometric quantitation of antithrombin-III (AT-III) development of a new assay. Thromb Res 1981; 24: 267-377
  • 8 Schmitz-Heubner U, Nachbar J, Asbeck F. The determination of antithrombin-III, α2-macroglobulin and α2-antiplasmin in plasma by laser nephelometry. J Clin Chem Clin Biochem 1980; 18: 221-226
  • 9 Scully MF, Kakkar VV. Methods for semi-micro or automated determination of thrombin, antithrombin and heparin cofactor using the substrate H-D-Phe-Pip-Arg-P-Nitroanilide-2 HCL. Clin Chim Acta 1977; 79: 595-602
  • 10 Sternberg JC. A rate nephelometer for measuring specific proteins by immunoprecipitin reactions. Clin Chem 1977; 23: 1456-1464
  • 11 Whicher JT, Price CP, Spencer K. Immunonephelometric and immunoturbidometric assays for proteins. CRC Crit Rev Clin Lab Sri 1983; 18: 213-360
  • 12 Wickerhauser M, Hao YL. Large-scale of plasma components for clinical use. In: Perspectives in hemostasis. Fareed J, Messmore HL, Fenton II JW, Brinkhous KM. (Eds) Pergamon Press Inc; New York: 1981. pp 258-268
  • 13 Wider G, Kulnigg E, Molinari E, Hotschek H, Bayer PM. Evaluation of a monitor guided nephelometric system. J Clin Chem Clin Biochem 1982; 20: 1-8