Thromb Haemost 1985; 53(03): 356-359
DOI: 10.1055/s-0038-1661314
Original Article
Schattauer GmbH Stuttgart

Bioimmunoassay (BIA) of Tissue Plasminogen Activator (t-PA) and Its Specific Inhibitor (t-PA/INH)

M Mahmoud
The National Institute for Biological Standards and Control, London, UK
,
P J Gaffney
The National Institute for Biological Standards and Control, London, UK
› Author Affiliations
Further Information

Publication History

Received 08 August 1984

Accepted 12 March 1985

Publication Date:
18 July 2018 (online)

Summary

A bioimmunoassay (BIA) for tissue plasminogen activator (t-PA) is described which depends on the binding of t-PA and its inhibitor complexes to an immobilised IgG to t-PA and the subsequent assessment of the bound t-PA using glutamic acid- plasminogen (glu-plgn) and the chromogenic substrate, S-2251. This assay indicated that neither normal plasma nor its euglobulin precipitate contain any measurable free and functionally active t-PA. The BIA was also used to measure the level of the fast acting specific t-PA inhibitor (t-PA/INH) in plasma by assessing the residual t-PA activity in the plasma euglobulin fraction (pH 5.9), following the addition of a known amount of t-PA to the plasma.

 
  • References

  • 1 Van de Werf F, Ludbrook PA, Bergmann SR, Tiefenbrunn AJ, Fox KA, De Geest H, Verstraete M, Collen D, Sobel BE. Coronary thrombolysis with tissue-type plasminogen activator in patients with evolving myocardial infarction. N Eng J Med 1984; 310: 609-613
  • 2 Gaffney PJ. The Fibrinolytic System. In: Haemostasis and Thrombosis. Bloom AL, Thomas DP. (eds) Churchill-Livingstone; Edinburgh: 1981: 198-224
  • 3 Rijken DC, Juhan-Vague I, De Cock F, Collen D. Measurement of human tissue-type plasminogen activator by a two-site immunoradiometric assay. J Lab Clin Med 1983; 101: 274-284
  • 4 Rijken DC, Van Hinsbergh VW M, Sens EH C. Quantitation of tissue-type plasminogen activator in human endothelial cell cultures by use of an enzyme immunoassay. Thromb Res 1984; 33: 145-153
  • 5 Verheijen JH, Mullaart E, Chang GT G, Kluft C, Wijngaards G. A simple sensitive spectrophotometric assay for extrinsic (tissue-type) plasminogen activator applicable to measurements in plasma. Thromb Haemostas 1982; 48: 266-269
  • 6 Ranby M, Norman IB, Wallen P. A sensitive assay for tissue plasminogen activator. Thromb Res 1982; 27: 743-749
  • 7 Rijken DC, Juhan-Vague I, Collen D. Complexes between tissue- type plasminogen activator and proteinase inhibitors in human plasma identified with an immunoradiometric assay. J Lab Clin Med 1983; 101: 285-294
  • 8 Haverkate F, Brakman P. Fibrin plate assay: Progress in Chemical Fibrinolysis and Thrombosis. Davidson JF, Samama MM, Desnoyers PC. (eds) Raven Press; New York: 1985. pp 151-159
  • 9 Nilsson IM, Olow B. Fibrinolysis induced by SK in man. Acta Chir Scand 1962; 123: 247-266
  • 10 Kruithof EK O, Ransijn A, Bachmann F. Inhibition of tissue- plasminogen activator by human plasma. Haemostasis 1982; 11: 60 (Abstr)
  • 11 Wiman B, Chmielewska J, Ranby M. Inactivation of tissue plasminogen activator in plasma. Demonstration of a complex with a new rapid inhibitor J Biol Chem 1984; 259: 3644-3647
  • 12 Kruithof EK O, Ransijn A, Tran-Thang C, Bachmann F. Characteristics of a fast-acting inhibitor of plasminogen activator in human plasma. Thromb Haemostas 1983; 50: 193 (Abstr)
  • 13 Philips M, Thorsen S. Binding of plasminogen activator (PA) to a component (x) of endothelial cells (EC) may explain the 95000-MrPA in human plasma. Thromb Haemostas 1983; 50: 193 (Abstr)
  • 14 Verheijen JH, Chang GT G, Mullaart E. Inhibition of extrinsic (tissue-type) plasminogen activator by human plasma: evidence for the occurrence of a fast-acting inhibitor. Thromb Haemostas 1983; 50: 294 (Abstr)
  • 15 Juhan-Vague I, Moerman B, De Cock F, Aillaud MF, Collen D. Plasma levels of a specific inhibitor of tissue-type plasminogen activator (and urokinase) in normal and pathological conditions. Thromb Res 1984; 33: 523-530
  • 16 Gaffney PH, Curtis AD. A collaborative study of a proposed international standard for tissue plasminogen activator (t-PA). Thromb Haemostas 1985; 53: 134-140
  • 17 Nilsson T, Wallen P, Mellbring G. Turnover of tissue type plasminogen activator in man. Haemostasis 1984; 14: 162 (Abstr)