The Journal of Hip Surgery 2018; 02(02): 092-096
DOI: 10.1055/s-0038-1661342
Original Article
Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

Total Hip Arthroplasty in Patients 21 Years and Younger Using Highly Cross-Linked Polyethylene: Excellent Survivorship at Five Years

Adam Sassoon
1   Department of Orthopaedic Surgery, University of California Los Angeles, Los Angeles, California
,
Muyibat Adelani
2   Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, Missouri
,
Frank Bohnenkamp
3   Department of Orthopedic Surgery, Crystal Lake Orthopedics, Crystal Lake, Illinois
,
Gail Pashos
2   Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, Missouri
,
John Clohisy
2   Department of Orthopaedic Surgery, Washington University in St. Louis, St. Louis, Missouri
› Author Affiliations
Further Information

Publication History

30 November 2017

19 April 2018

Publication Date:
22 June 2018 (online)

Abstract

The survivorship of contemporary total hip arthroplasty has improved substantially as a result of the success of highly cross-linked polyethylene. Nevertheless, there is limited information on its performance in extremely young patients. The purpose of this study is to evaluate the (1) clinical and radiographic outcomes, (2) polyethylene wear rates, and (3) mid-term survivorship of total hip arthroplasty in patients 21 years or younger using highly cross-linked polyethylene. After Institutional Review Board approval, the authors identified 45 patients aged 21 years or younger (56 hips) who underwent primary total hip arthroplasty with highly cross-linked polyethylene at their institution by the senior author between 2000 and 2009. Patients were followed for a minimum of 2 years, or until revision. At a mean follow-up of 57 months, modified Harris Hip Scores, Western Ontario McMaster Universities Arthritis Index scores, Short Form-12 physical function scores, and University of California, Los Angeles activity scores improved significantly in all patients. There was no radiographic evidence of osteolysis in any patient. The mean linear polyethylene wear rate was 0.02 mm per year. Survivorship was 98% with one revision for acetabular loosening at 71 months. Total hip arthroplasty in patients 21 years or younger with highly cross-linked polyethylene had excellent clinical and radiographic outcomes at mid-term follow-up. Longer-term data are needed in this patient population to confirm continued survivorship in the extremely young. The level of evidence used for this study was level III.

 
  • References

  • 1 Kurtz SM, Lau E, Ong K, Zhao K, Kelly M, Bozic KJ. Future young patient demand for primary and revision joint replacement: national projections from 2010 to 2030. Clin Orthop Relat Res 2009; 467 (10) 2606-2612
  • 2 Shia DS, Clohisy JC, Schinsky MF, Martell JM, Maloney WJ. THA with highly cross-linked polyethylene in patients 50 years or younger. Clin Orthop Relat Res 2009; 467 (08) 2059-2065
  • 3 Sedrakyan A, Romero L, Graves S. , et al. Survivorship of hip and knee implants in pediatric and young adult populations: analysis of registry and published data. J Bone Joint Surg Am 2014; 96 (Suppl. 01) 73-78
  • 4 Kim YH, Park JW, Patel C, Kim DY. Polyethylene wear and osteolysis after cementless total hip arthroplasty with alumina-on-highly cross-linked polyethylene bearings in patients younger than thirty years of age. J Bone Joint Surg Am 2013; 95 (12) 1088-1093
  • 5 Kim YH, Choi Y, Kim JS. Cementless total hip arthroplasty with alumina-on-highly cross-linked polyethylene bearing in young patients with femoral head osteonecrosis. J Arthroplasty 2011; 26 (02) 218-223
  • 6 Babovic N, Trousdale RT. Total hip arthroplasty using highly cross-linked polyethylene in patients younger than 50 years with minimum 10-year follow-up. J Arthroplasty 2013; 28 (05) 815-817
  • 7 Clohisy JC, Oryhon JM, Seyler TM. , et al. Function and fixation of total hip arthroplasty in patients 25 years of age or younger. Clin Orthop Relat Res 2010; 468 (12) 3207-3213
  • 8 Keeney JA, Martell JM, Pashos G, Nelson CJ, Maloney WJ, Clohisy JC. Highly cross-linked polyethylene improves wear and mid-term failure rates for young total hip arthroplasty patients. Hip Int 2015; 25 (05) 435-441
  • 9 Adelani MA, Keeney JA, Palisch A, Fowler SA, Clohisy JC. Has total hip arthroplasty in patients 30 years or younger improved? A systematic review. Clin Orthop Relat Res 2013; 471 (08) 2595-2601
  • 10 Paxton EW, Inacio MC, Namba RS, Love R, Kurtz SM. Metal-on-conventional polyethylene total hip arthroplasty bearing surfaces have a higher risk of revision than metal-on-highly crosslinked polyethylene: results from a US registry. Clin Orthop Relat Res 2015; 473 (03) 1011-1021
  • 11 Kurtz SM, Gawel HA, Patel JD. History and systematic review of wear and osteolysis outcomes for first-generation highly crosslinked polyethylene. Clin Orthop Relat Res 2011; 469 (08) 2262-2277
  • 12 Stambough JB, Pashos G, Bohnenkamp FC, Maloney WJ, Martell JM, Clohisy JC. Long-term results of total hip arthroplasty with 28-millimeter Cobalt-chromium femoral heads on highly cross-linked polyethylene in patients 50 years and less. J Arthroplasty 2016; 31 (01) 162-167
  • 13 Garvin KL, White TC, Dusad A, Hartman CW, Martell J. Low wear rates seen in THAs with highly crosslinked polyethylene at 9 to 14 years in patients younger than age 50 years. Clin Orthop Relat Res 2015; 473 (12) 3829-3835
  • 14 Finkbone PR, Severson EP, Cabanela ME, Trousdale RT. Ceramic-on-ceramic total hip arthroplasty in patients younger than 20 years. J Arthroplasty 2012; 27 (02) 213-219
  • 15 Kamath AF, Sheth NP, Hosalkar HH, Babatunde OM, Lee GC, Nelson CL. Modern total hip arthroplasty in patients younger than 21 years. J Arthroplasty 2012; 27 (03) 402-408
  • 16 Hwang KT, Kim YH, Kim YS, Choi IY. Cementless total hip arthroplasty with a metal-on-metal bearing in patients younger than 50 years. J Arthroplasty 2011; 26 (08) 1481-1487
  • 17 Kim YH, Park JW, Kim JS. Cementless metaphyseal fitting anatomic total hip arthroplasty with a ceramic-on-ceramic bearing in patients thirty years of age or younger. J Bone Joint Surg Am 2012; 94 (17) 1570-1575
  • 18 Kim YH, Choi Y, Kim JS. Cementless total hip arthroplasty with ceramic-on-ceramic bearing in patients younger than 45 years with femoral-head osteonecrosis. Int Orthop 2010; 34 (08) 1123-1127
  • 19 Byun JW, Yoon TR, Park KS, Seon JK. Third-generation ceramic-on-ceramic total hip arthroplasty in patients younger than 30 years with osteonecrosis of femoral head. J Arthroplasty 2012; 27 (07) 1337-1343
  • 20 Amstutz HC, Thomas BJ, Jinnah R, Kim W, Grogan T, Yale C. Treatment of primary osteoarthritis of the hip. A comparison of total joint and surface replacement arthroplasty. J Bone Joint Surg Am 1984; 66 (02) 228-241
  • 21 Keeney JA, Nunley RM, Baca GR, Clohisy JC. Are younger patients undergoing THA appropriately characterized as active?. Clin Orthop Relat Res 2015; 473 (03) 1083-1092
  • 22 Bauman S, Williams D, Petruccelli D, Elliott W, de Beer J. Physical activity after total joint replacement: a cross-sectional survey. Clin J Sport Med 2007; 17 (02) 104-108
  • 23 Smith MV, Klein SE, Clohisy JC, Baca GR, Brophy RH, Wright RW. Lower extremity-specific measures of disability and outcomes in orthopaedic surgery. J Bone Joint Surg Am 2012; 94 (05) 468-477
  • 24 Lubetkin EI, Gold MR. Areas of decrement in health-related quality of life (HRQL): comparing the SF-12, EQ-5D, and HUI 3. Qual Life Res 2003; 12 (08) 1059-1067