J Knee Surg 2021; 34(01): 108-114
DOI: 10.1055/s-0039-1693668
Original Article

Lower Limb Malrotation Is Regularly Present in Long-Leg Radiographs Resulting in Significant Measurement Errors

Günther Maderbacher
1   Department of Orthopaedic Surgery, University of Regensburg, Regensburg, Germany
,
Jan Matussek
1   Department of Orthopaedic Surgery, University of Regensburg, Regensburg, Germany
,
Felix Greimel
1   Department of Orthopaedic Surgery, University of Regensburg, Regensburg, Germany
,
Joachim Grifka
1   Department of Orthopaedic Surgery, University of Regensburg, Regensburg, Germany
,
Jens Schaumburger
1   Department of Orthopaedic Surgery, University of Regensburg, Regensburg, Germany
,
Clemens Baier
1   Department of Orthopaedic Surgery, University of Regensburg, Regensburg, Germany
,
Armin Keshmiri
1   Department of Orthopaedic Surgery, University of Regensburg, Regensburg, Germany
› Author Affiliations
Funding None.

Abstract

Weight-bearing long-leg radiographs are commonly used in orthopaedic surgery. Measured parameters, however, change when radiographs are conducted in different rotational positions of the leg. It was hypothesized that rotational errors are regularly present in long-leg radiographs resulting in wrong measurements. In 100 consecutive long-leg radiographs conducted according to the method of Paley, rotation was assessed by fibular overlap. Angular parameters in radiographs (mechanical lateral proximal femoral angle (mLPFA), mechanical lateral distal femoral angle (mLDFA), angle between the anatomical and mechanical femoral axis (AMA), mechanical medial proximal tibia angle (mMPTA), mechanical lateral distal tibial angle (mLDTA), and the mechanical femoral and tibial axis (mFA–mTA) were measured and deviations related to malrotation calculated. An average internal rotation of 8 degrees was found in lower limbs showing a range between 29 degrees of internal and 22 degrees of external rotation. As a result, mean differences before and after rotational correction for measured parameters (mLPFA, mLDFA, AMA, mMPTA, mLDTA, mFA–mTA) ranged between 0.4 and 1.7 degrees (−2.1; 5.6 95% confidence interval [CI]). In conclusion, malrotation of lower limbs is regularly present in long-leg radiographs. As all measured parameters are influenced by malrotation, correct lower limb rotation needs to be verified.



Publication History

Received: 06 January 2019

Accepted: 27 May 2019

Article published online:
29 July 2019

© 2020. Thieme. All rights reserved.

Thieme Medical Publishers, Inc.
333 Seventh Avenue, 18th Floor, New York, NY 10001, USA

 
  • References

  • 1 Bellemans J, Colyn W, Vandenneucker H, Victor J. The Chitranjan Ranawat award: is neutral mechanical alignment normal for all patients? The concept of constitutional varus. Clin Orthop Relat Res 2012; 470 (01) 45-53
  • 2 Chao EY, Neluheni EV, Hsu RW, Paley D. Biomechanics of malalignment. Orthop Clin North Am 1994; 25 (03) 379-386
  • 3 Paley D. Principles of Deformity Correction. Haiedleberg; Berlin: Springer-Verlag Berlin-Heidelberg; 2005: 1-30
  • 4 Paley D, Herzenberg JE, Tetsworth K, McKie J, Bhave A. Deformity planning for frontal and sagittal plane corrective osteotomies. Orthop Clin North Am 1994; 25 (03) 425-465
  • 5 Jiang CC, Insall JN. Effect of rotation on the axial alignment of the femur. Pitfalls in the use of femoral intramedullary guides in total knee arthroplasty. Clin Orthop Relat Res 1989; (248) 50-56
  • 6 Lonner JH, Laird MT, Stuchin SA. Effect of rotation and knee flexion on radiographic alignment in total knee arthroplasties. Clin Orthop Relat Res 1996; (331) 102-106
  • 7 Maderbacher G, Baier C, Benditz A. et al. Presence of rotational errors in long leg radiographs after total knee arthroplasty and impact on measured lower limb and component alignment. Int Orthop 2017; 41 (08) 1553-1560
  • 8 Radtke K, Becher C, Noll Y, Ostermeier S. Effect of limb rotation on radiographic alignment in total knee arthroplasties. Arch Orthop Trauma Surg 2010; 130 (04) 451-457
  • 9 Wright JG, Treble N, Feinstein AR. Measurement of lower limb alignment using long radiographs. J Bone Joint Surg Br 1991; 73 (05) 721-723
  • 10 Cooke TD, Scudamore RA, Bryant JT, Sorbie C, Siu D, Fisher B. A quantitative approach to radiography of the lower limb. Principles and applications. J Bone Joint Surg Br 1991; 73 (05) 715-720
  • 11 Cooke TD, Sled EA. Optimizing limb position for measuring knee anatomical axis alignment from standing knee radiographs. J Rheumatol 2009; 36 (03) 472-477
  • 12 Maderbacher G, Schaumburger J, Baier C. et al. Predicting knee rotation by the projection overlap of the proximal fibula and tibia in long-leg radiographs. Knee Surg Sports Traumatol Arthrosc 2014; 22 (12) 2982-2988
  • 13 Maderbacher G, Keshmiri A, Schaumburger J. et al. What is the optimal valgus pre-set for intramedullary femoral alignment rods in total knee arthroplasty?. Knee Surg Sports Traumatol Arthrosc 2017; 25 (11) 3480-3487
  • 14 Maderbacher G, Matussek J, Keshmiri A. et al. Rotation of intramedullary alignment rods affects distal femoral cutting plane in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 2018; 26 (11) 3311-3316
  • 15 Akagi M, Oh M, Nonaka T, Tsujimoto H, Asano T, Hamanishi C. An anteroposterior axis of the tibia for total knee arthroplasty. Clin Orthop Relat Res 2004; (420) 213-219