ABSTRACT
Objectives: The objective of this in vitro study was to evaluate the marginal sealing ability of an ormocer in comparison with a hybrid composite when using thermocycling and load cycling procedures together in the study design.
Methods: Modified proximal Class II cavities were prepared on the mesial and distal surfaces of twenty-two human premolars. Each tooth was restored with Admira and contralaterally with TPH Spectrum. Half of all of the teeth were subjected to thermo-mechanical load cycling. After dye penetration, longitudinal sections in mesio-distal direction were prepared and examined under a stereomicroscope. Data were analyzed with Mann Whitney U test.
Results: The results showed that the thermo-mechanical load cycling caused a statistically significant increase in gingival microleakage when compared with the non-thermocycled and nonloaded restorations for both the materials Admira (P=0.006) and TPH Spectrum (P=0.023).
Conclusions: Simultaneous load cycling and thermocycling are decisive factors in the in vitro assessment of gingival microleakage, which still remains to be a clinical problem even with the ormocer system Admira. (Eur J Dent 2009;3:200-206)