Objectives: The purpose of this study was to evaluate flexural strengths, moduli, and maximum deflection of Clearfil AP-X (APX) and Ceram-X Mono (CXM) when cured with a quartz-tungsten halogen (QTH) or an LED-light (LED).
Methods: Specimens were made according to ISO 4049 and cured with QTH or LED for 10, 20 or 60 s. Flexural strength, modulus, and deflection were determined after 24 h water storage at 37°C and after thermocycling. Statistical significance was P<.05.
Results: Flexural strength did not depend on energy density or curing light and was significantly higher for APX than for CXM but decreased after thermocycling for both materials. Modulus and deflection depended on energy density. Modulus was significantly higher for APX than for CXM and increased for APX but decreased for CXM after thermocycling. Deflection decreased with increasing energy density and decreased after thermocycling. Though energy density did not influence flexural strength, it positively correlated with flexural modulus and negatively with maximum deflection.
Conclusions: Energy density did not influence flexural strength but modulus and deflection. Thermocycling affected all material properties. The LED was as effective as the QTH. (Eur J Dent 2010;4:183-191)
-
References
- 1 Leonard D, Charlton D, Roberts H, Cohen M. Polymerization efficiency of LED curing lights. J Esthet Restor Dent 2002; 14: 286-295
- 2 Uhl A, Mills RW, Vowles RW, Jandt KD. Knoop hardness depth profiles and compressive strength of selected dental composites polymerized with halogen and LED light curing technologies. J Biomed Mater Res 2002; 63: 729-738
- 3 Schneider LF, Consani S, Correr-Sobrinho L, Correr AB, Sinhoreti MA. Halogen and LED light curing of composite: temperature increase and Knoop hardness. Clin Oral Investig 2006; 10: 66-71
- 4 Yap AU, Soh MS, Han TT, Siow KS. Influence of curing lights and modes on cross-link density of dental composites. Oper Dent 2004; 29: 410-415
- 5 Tsai PC, Meyers IA, Walsh LJ. Depth of cure and surface microhardness of composite resin cured with blue LED curing lights. Dent Mater 2004; 20: 364-369
- 6 Knezevic A, Tarle Z, Meniga A, Sutalo J, Pichler G. Influence of light intensity from different curing units upon composite temperature rise. J Oral Rehabil 2005; 32: 362-367
- 7 Knezevic A, Tarle Z, Meniga A, Sutalo J, Pichler G, Ristic M. Degree of conversion and temperature rise during polymerization of composite resin samples with blue diodes. J Oral Rehabil 2001; 28: 586-591
- 8 Uhl A, Volpel A, Sigusch BW. Influence of heat from light curing units and dental composite polymerization on cells in vitro. J Dent 2006; 34: 298-306
- 9 Campregher UB, Samuel SM, Fortes CB, Medina AD, Collares FM, Ogliari FA. Effectiveness of second-generation light-emitting diode (LED) light curing units. J Contemp Dent Pract 2007; 8: 35-42
- 10 Hasler C, Zimmerli B, Lussi A. Curing capability of halogen and LED light curing units in deep class II cavities in extracted human molars. Oper Dent 2006; 31: 354-363
- 11 Uhl A, Mills RW, Rzanny AE, Jandt KD. Time dependence of composite shrinkage using halogen and LED light curing. Dent Mater 2005; 21: 278-286
- 12 Bala O, Olmez A, Kalayci S. Effect of LED and halogen light curing on polymerization of resin-based composites. J Oral Rehabil 2005; 32: 134-140
- 13 Fleming GJ, Khan S, Afzal O, Palin WM, Burke FJ. Investigation of polymerisation shrinkage strain, associated cuspal movement and microleakage of MOD cavities restored incrementally with resin-based composite using an LED light curing unit. J Dent 2007; 35: 97-103
- 14 Soh MS, Yap AU, Yu T, Shen ZX. Analysis of degree of conversion of LED and halogen lights using micro-Raman spectroscopy. Oper Dent 2004; 29: 571-577
- 15 Beun S, Glorieux T, Devaux J, Vreven J, Leloup G. Characterization of nanofilled compared to universal and microfilled composites. Dent Mater 2007; 23: 51-59
- 16 Stahl F, Ashworth SH, Jandt KD, Mills RW. Light-emitting diode (LED) polymerisation of dental composites: flexural properties and polymerisation potential. Biomaterials 2000; 21: 1379-1385
- 17 Besnault C, Pradelle-Plasse N, Picard B, Colon P. Effect of a LED versus halogen light cure polymerization on the curing characteristics of three composite resins. Am J Dent 2003; 16: 323-328
- 18 EN ISO 4049:2000 Dentistry -Polymer-based filling, restorative and luting materials.
- 19 Price RB, Felix CA. Effect of delivering light in specific narrow bandwidths from 394 to 515nm on the micro-hardness of resin composites. Dent Mater 2009; 25: 899-908
- 20 Mobarak E, Elsayad I, Ibrahim M, El-Badrawy W. Effect of LED light-curing on the relative hardness of tooth-colored restorative materials. Oper Dent 2009; 34: 65-71
- 21 Gritsch K, Souvannasot S, Schembri C, Farge P, Grosgogeat B. Influence of light energy and power density on the microhardness of two nanohybrid composites. Eur J Oral Sci 2008; 116: 77-82
- 22 Silva CM, Dias KR. Compressive strength of esthetic restorative materials polymerized with quartz-tungsten-halogen light and blue LED. Braz Dent J 2009; 20: 54-57
- 23 Kwon YH, Jeon GH, Jang CM, Seol HJ, Kim HI. Evaluation of polymerization of light-curing hybrid composite resins. J Biomed Mater Res B Appl Biomater 2006; 76: 106-113
- 24 Janda R, Roulet JF, Latta M, Ruttermann S. The effects of thermocycling on the flexural strength and flexural modulus of modern resin-based filling materials. Dent Mater 2006; 22: 1103-1108
- 25 Pilato LA, Michno MJ. Advanced composite materials. Editor; Springer, New York: 1994
- 26 Sambasivan S, Fischer DA, Shen MC, Hsu SM. Molecular orientation of ultrahigh molecular weight polyethylene induced by various sliding motions. J Biomed Mater Res B Appl Biomater 2004; 70: 278-285
- 27 Edidin AA, Jewett CW, Kalinowski A, Kwarteng K, Kurtz SM. Degradation of mechanical behavior in UHMWPE after natural and accelerated aging. Biomaterials 2000; 21: 1451-1460
- 28 Teoh SH, Martin RL, Lim SC, Lee KH, Mok CK, Kwok WC. Delrin as an occluder material. ASAIO Trans 1990; 36: M417-421
- 29 Kostoulas I, Kavoura VT, Frangou MJ, Polyzois GL. Fracture force, deflection, and toughness of acrylic denture repairs involving glass fiber reinforcement. J Prosthodont 2008; 17: 257-261
- 30 Uzun G, Keyf F. The effect of fiber reinforcement type and water storage on strength properties of a provisional fixed partial denture resin. J Biomater Appl 2003; 17: 277-286
- 31 Peutzfeldt A, Asmussen E. Resin composite properties and energy density of light cure. J Dent Res 2005; 84: 659-662
- 32 Sideridou I, Tserki V, Papanastasiou G. Effect of chemical structure on degree of conversion in light-cured dimethacrylate-based dental resins. Biomaterials 2002; 23: 1819-1829
- 33 Peutzfeldt A. Resin composites in dentistry: the monomer systems. Eur J Oral Sci 1997; 105: 97-116
- 34 Owens BM, Rodriguez KH. Radiometric and spectrophotometric analysis of third generation light-emitting diode (LED) light-curing units. J Contemp Dent Pract 2007; 8: 43-51
- 35 Wendl B, Droschl H, Kern W. A comparative study of polymerization lamps to determine the degree of cure of composites using infrared spectroscopy. Eur J Orthod 2004; 26: 545-551
- 36 Asmussen E, Peutzfeldt A. Flexural strength and modulus of a step-cured resin composite. Acta Odontol Scand 2004; 62: 87-90
- 37 Musanje L, Darvell BW. Polymerization of resin composite restorative materials: exposure reciprocity. Dent Mater 2003; 19: 531-541
- 38 Rodrigues Jr SA, Zanchi CH, Carvalho RV, Demarco FF. Flexural strength and modulus of elasticity of different types of resin-based composites. Braz Oral Res 2007; 21: 16-21
- 39 Turssi CP, Ferracane JL, Ferracane LL. Wear and fatigue behavior of nano-structured dental resin composites. J Biomed Mater Res B Appl Biomater 2006; 78: 196-203
- 40 Scientific Documentation Ceram-X Mono, DeTrey Dentsply GmbH, Constance, Germany. 2003
- 41 Instructions for Use Ceram-X Mono, DeTrey Dentsply GmbH, Constance, Germany. 2003
- 42 Soh MS, Yap AU. Influence of curing modes on crosslink density in polymer structures. J Dent 2004; 32: 321-326