CC BY-NC-ND 4.0 · Eur J Dent 2010; 04(03): 280-286
DOI: 10.1055/s-0039-1697840
Original Article
European Journal of Dentistry

Influence of Blood Contamination on Bond Strength of a Self-Etching System

Ellen Cristina de Carvalho Mendonça
a   Department of Restorative Dentistry, School of Dentistry University of Sao Paulo (USP), São Paulo, SP, Brazil
,
Samuel Nilo Vieira
b   Department of Restorative Dentistry, School of Dentistry University of Sao Paulo (USP), São Paulo, SP, Brazil
,
Fernando Aparecido Kawaguchi
c   Department of Restorative Dentistry, School of Dentistry University of Sao Paulo (USP), São Paulo, SP, Brazil
,
John Powers
d   Department of Restorative Dentistry and Biomaterials, University of Texas Dental Branch at Houston, Houston, TX, USA
,
Adriana Bona Matos
e   Department of Restorative Dentistry, School of Dentistry University of Sao Paulo (USP), São Paulo, SP, Brazil
› Author Affiliations
Further Information

Publication History

Publication Date:
30 September 2019 (online)

Objectives: To detect the influence of blood contamination (BC) on the bond strength (BS) of a selfetching bonding system (SES) to enamel and dentine.

Methods: 25 human molars were longitudinally sectioned on the mesio-distal axis in order to obtain 50 specimens, which were embedded in acrylic resin. At first, the specimens were ground to expose a flat surface of enamel, and a bond strength test was performed. Afterwards, the samples were ground again in order to obtain a flat surface of dentine. Ten groups (total: n=100) were assigned according to substrate (enamel and dentine), step in the bonding sequence when contamination occurred (before the acidic primer and after the bonding resin), and contamination treatment (dry or rinse and dry procedure). Fresh human blood was introduced either before or after SES application (Clearfil SE Bond) and treated with air drying, or by rinsing and drying following application. Composite resin (Filtek Z-250,3M ESPE) was applied as inverted, truncated cured cones that were debonded in tension.

Results: The mean tensile BS values (MPa) for enamel/dentine were 19.4/23.0 and 17.1/10.0 for rinse-and-dry treatment (contamination before and after SES, respectively); while the measurements for the dry treatment, 16.2/23.3 and 0.0/0.0 contamination before and after SES, respectively.

Conclusions: It was determined that blood contamination impaired adhesion to enamel and dentine when it occurred after bond light curing. Among the tested contamination treatments, the rinseand- dry treatment produced the highest bond strength with BC after SES application, but it was not sufficient to recover the BS in the contamination-free group. (Eur J Dent 2010;4:280-286)

 
  • REFERENCES

  • 1 Yazici AR, Tuncer D, Dayangac B, Ozgunaltay G, Onen A. The effect of saliva contamination on microleakage of an etch-and-rinse and a self-etching adhesive. J Adhes Dent 2007; 9: 305-309
  • 2 Reddy L, Marker VA, Ellis 3rd E. Bond strength for orthodontic brackets contaminated by blood: composite versus resin-modified glass ionomer cements. J Oral Maxillofac Surg 2003; 61: 206-213
  • 3 Oonsombat C, Bishara SE, Ajlouni R. The effect of blood contamination on the shear bond strength of orthodontic brackets with the use of a new self-etch primer. Am J Orthod Dentofacial Orthop 2003; 123: 547-550
  • 4 Sfondrini MF, Cacciafesta V, Scribante A, De MAngelis, Klersy C. Effect of blood contamination on shear bond strength of brackets bonded with conventional and self-etching primers. Am J Orthod Dentofacial Orthop 2004; 125: 357-360
  • 5 Sayinsu K, Isik F, Sezen S, Aydemir B. Light curing the primer-beneficial when working in problem areas?. Angle Orthod 2006; 76: 310-313
  • 6 Oztoprak MO, Isik F, Sayinsu K, Arun T, Aydemir B. Effect of blood and saliva contamination on shear bond strength of brackets bonded with 4 adhesives. Am J Orthod Dentofacial Orthop 2007; 131: 238-242
  • 7 Pashley EL, Tao L, Mackert JR, Pashley DH. Comparison of in vivo vs. in vitro bonding of composite resin to the dentin of canine teeth. J Dent Res 1988; 67: 467-470
  • 8 Schattenberg A, Werling U, Willershausen B, Ernst CP. Two-year clinical performance of two one-step self-etching adhesives in the restoration of cervical lesions. Clin Oral Investig 2008; 12: 225-232
  • 9 Joynt RB, Davis EL, Schreier PH. Rubber dam usage among practicing dentists. Oper Dent 1989; 14: 176-181
  • 10 Strydom C. Handling protocol of posterior composites Rubber Dam. SADJ 2005; 60: 292-293
  • 11 Barakat MM, Powers JM. In vitro bond strength of cements to treated teeth. Aust Dent J 1986; 31: 415-419
  • 12 Powers JM, Finger WJ, Xie J. Bonding of composite resin to contaminated human enamel and dentin. J Prosthodont 1995; 4: 28-32
  • 13 Peschke A, Blunck U, Roulet JF. Influence of incorrect application of a water-based adhesive system on the marginal adaptation of Class V restorations. Am J Dent 2000; 13: 239-244
  • 14 Fritz UB, Finger WJ, Stean H. Salivary contamination during bonding procedures with a one-bottle adhesive system. Quintessence Int 1998; 29: 567-572
  • 15 el-Kalla IH, Garcia-Godoy F. Saliva contamination and bond strength of single-bottle adhesives to enamel and dentin. Am J Dent 1997; 10: 83-87
  • 16 Johnson ME, Burgess JO, Hermesch CB, Buikema DJ. Saliva contamination of dentin bonding agents. Oper Dent 1994; 19: 205-210
  • 17 Xie J, Powers JM, McGuckin RS. In vitro bond strength of two adhesives to enamel and dentin under normal and contaminated conditions. Dent Mater 1993; 9: 295-299
  • 18 Abdalla AI, Davidson CL. Bonding efficiency and interfacial morphology of one-bottle adhesives to contaminated dentin surfaces. Am J Dent 1998; 11: 281-285
  • 19 Sattabanasuk V, Shimada Y, Tagami J. Effects of saliva contamination on dentin bond strength using all-in-one adhesives. J Adhes Dent 2006; 8: 311-318
  • 20 Yoo HM, Pereira PN. Effect of blood contamination with 1-step self-etching adhesives on microtensile bond strength to dentin. Oper Dent 2006; 31: 660-665
  • 21 van JHSchalkwyk, Botha FS, van PJder Vyver, de FAWet, Botha SJ. Effect of biological contamination on dentine bond strength of adhesive resins. SADJ 2003; 58: 143-147
  • 22 Pashley DH. Dentin bonding: overview of the substrate with respect to adhesive material. J Esthet Dent 1991; 3: 46-50
  • 23 Miles DA, Anderson RW, Pashley DH. Evaluation of the bond strength of dentin bonding agents used to seal resected root apices. J Endod 1994; 20: 538-541
  • 24 Kaneshima T, Yatani H, Kasai T, Watanabe EK, Yamashita A. The influence of blood contamination on bond strengths between dentin and an adhesive resin cement. Oper Dent 2000; 25: 195-201
  • 25 Hobson RS, Ledvinka J, Meechan JG. The effect of moisture and blood contamination on bond strength of a new orthodontic bonding material. Am J Orthod Dentofacial Orthop 2001; 120: 54-57
  • 26 Faltermeier A, Behr M, Rosentritt M, Reicheneder C, Müssig D. An in vitro comparative assessment of different enamel contaminants during bracket bonding. Eur J Orthod 2007; 29: 559-563
  • 27 Eiriksson SO, Pereira PN, Swift EJ, Heymann HO, Sigurdsson A. Effects of blood contamination on resin-resin bond strength. Dent Mater 2004; 20: 184-190
  • 28 Dietrich T, Kraemer M, Losche GM, Wernecke KD, Roulet JF. Influence of dentin conditioning and contamination on the marginal integrity of sandwich Class II restorations. Oper Dent 2000; 25: 401-410
  • 29 Sayinsu K, Isik F, Sezen S, Aydemir B. Effect of blood and saliva contamination on bond strength of brackets bonded with a protective liquid polish and a light-cured adhesive. Am J Orthod Dentofacial Orthop 2007; 131: 391-394
  • 30 Itoh T, Fukushima T, Inoue Y, Matsuo N, Matsumoto M. Bond strength of brackets cemented with light-cured glass-ionomer cements to contaminated enamel. Am J Dent 2000; 13: 181-186
  • 31 Cacciafesta V, Sfondrini MF, Scribante A, De MAngelis, Klersy C. Effects of blood contamination on the shear bond strengths of conventional and hydrophilic primers. Am J Orthod Dentofacial Orthop 2004; 126: 207-212
  • 32 Cacciafesta V, Sfondrini MF, Scribante A, De MAngelis, Klersy C. Effect of blood contamination on shear bond strength of brackets bonded with a self-etching primer combined with a resin-modified glass ionomer. Am J Orthod Dentofacial Orthop 2004; 126: 703-708
  • 33 Kirovski I, Madzarova S. Tensile bond strength of a lightcured glass ionomer cement when used for bracket bonding under different conditions: an in vitro study. Eur J Orthod 2000; 22: 719-723
  • 34 Dietrich T, Kraemer ML, Roulet JF. Blood contamination and dentin bonding--effect of anticoagulant in laboratory studies. Dent Mater 2002; 18: 159-162
  • 35 Ernst CP, Brandenbusch M, Meyer G, Canbek K, Gottschalk F, Willershausen B. Two-year clinical performance of a nanofiller vs a fine-particle hybrid resin composite. Clin Oral Investig 2006; 10: 119-125
  • 36 De JMunck, Van KLanduyt, Peumans M. et al A critical review of the durability of adhesion to tooth tissue: methods and results. J Dent Res 2005; 84: 118-132
  • 37 Van BMeerbeek, Perdigão J, Lambrechts P, Vanherle G. The clinical performance of dentin adhesives. J Dent 1998; 1-20
  • 38 Tay FR, Pashley DH. Have dentin adhesives become too hydrophilic?. J Can Dent Assoc 2003; 69: 726-731
  • 39 Kaaden C, Powers JM, Friedl KH, Schmalz G. Bond strength of self-etching adhesives to dental hard tissues. Clin Oral Investig 2002; 6: 155-160
  • 40 Reynolds IR. A review of direct orthodontic bonding. Br J Orthod 1975; 2: 171-178
  • 41 Davidson CL, de AJGee, Feilzer A. The competition between the composite-dentin bond strength and the polymerization contraction stress. J Dent Res 1984; 63: 1396-1399
  • 42 Benderli Y, Gokce K, Buyukgokcesu S. In vitro shear bond strength of adhesive to normal and fluoridated enamel under various contaminated conditions. Quintessence Int 1999; 30: 570-575