CC BY-NC-ND 4.0 · Indian J Plast Surg 2006; 39(01): 42-50
DOI: 10.1055/s-0039-1700460
Original Article
Association of Plastic Surgeons of India

A scanning electron microscopic evaluation of microsurgical anastomosis by conventional end to end and end to end anastomosis using “temporary stent” technique: An experimental study

M. Chaware Suresh
Departments of Plastic and Reconstructive Surgery, King Georges Medical University, Lucknow, U.P., India
,
S K Bhatnagar
Departments of Plastic and Reconstructive Surgery, King Georges Medical University, Lucknow, U.P., India
,
A K Singh
Departments of Plastic and Reconstructive Surgery, King Georges Medical University, Lucknow, U.P., India
› Institutsangaben
Weitere Informationen

Publikationsverlauf

Publikationsdatum:
15. Januar 2020 (online)

Abstract

Background: The art of microvascular repair progressed slowly over a century after Carrel′s original description of ′vascular repair′ in 1902. Reports of the successful repair of vessels smaller than one mm in diameter are currently commonplace. However, the art of microvascular surgery has not yet been perfected, as evidenced by frequent reports of clinical failure. This study was undertaken to determine the effect of a ′temporary stent′ on the patency rates of vessels and to study the vascular endothelium under electron microscope to determine the changes caused by both conventional and the experimental technique.

Materials and Methods: This study consisted of two distinct arms. In the first part (27 rats) we studied the effect of temporary stenting on end to end anastomosis vis a vis its patency rates. While in the second part (30 rats) the same experiment was performed with a view to examine the anastomosis under electron microscope at different time frames to study the state of the endothelium in the vessel lumen at the site of anastomosis and also along the length of the vessel up to the point where clamps were applied.

Results: In our study conventional end-to-end microvascular anastomoses had late patency rate of 70.37%. While end-to-end microvascular anastomoses using temporary stent had patency rate of 92.59%. On electron microscopic study, it was observed that, the endothelial damage was less in the stented group.

Conclusion: Stent technique produces lesser degree of trauma to the vessel and no serious complications compared to the conventional dilatation and manipulation with vessel dilator.

 
  • 1 Carrel A.. La technique operatoire des anastomoses vasculaires et la transplantation des visceres. Lyon Med 1902; 98: 859
  • 2 Moskovitz MJ, Bass L, Zhang L, Siebert JW. Microvascular anastomoses utilising new intravascular stents. Ann Plast Surg 1994; 32: 612-8
  • 3 Wei FC, Mancer K, Zuker RM. The temporary stent technique: An easier method of microvenous anastomosis. Br J Plast Surg 1982; 35: 92-5
  • 4 Buss H, Hollweg HGG. Scanning Electron Microscopy of blood vessels: A review, in “SEM Illinisis Institute of Technical Research Institute. vol 2 edited by Johari O, Becker RP. 1977; p. 467
  • 5 Thurston JB, Bunsel HI, Chater NL. A scanning electron microscopy study of microarterial damage and repair. Plast Reconstr Surg 1976; 57: 197-203
  • 6 Nightingale G., Fogdestam I, Mc B. Scanning electron microscope study of an experimental microvascular anastomoses in the rabbit. Br J Plast Surg 1980; 33: 283-93