Am J Perinatol 2021; 38(06): 609-613
DOI: 10.1055/s-0039-1700863
Original Article

Intra- and Inter-Rater Agreement between X-Ray Views for Umbilical Catheter Position

1   Department of Pediatrics, JSS Medical College, JSS Academy of Higher Education and Research, Mysuru, India
,
Sumesh Thomas
2   Department of Pediatrics, University of Calgary, Calgary, Canada
,
Sourabh Dutta
3   Department of Pediatrics, McMaster University, Hamilton, Canada
› Author Affiliations
Funding None.

Abstract

Objective We determined intra- and inter-rater agreement for umbilical arterial/venous catheter (umbilical arterial catheter [UAC] and umbilical venous catheter [UVC], respectively) positions on supine anteroposterior (AP) and horizontal dorsal decubitus (HDD) X-ray views to determine whether two views are routinely required.

Study Design This retrospective study was conducted in McMaster University, Canada. Pairs of AP and HDD radiographs were coded and rated in random sequence by two experienced raters. Primary outcome was intra-rater agreement (κ) between AP and HDD views for UVC catheter tip position. Secondary outcomes included inter-rater κ for UVC position; inter- and intra-rater κ for UAC position, inter- and intra-rater κ for follow-up action. To detect κ of 0.8 (width of 95% confidence interval = 0.1), 138 radiograph pairs were required.

Results Intra-rater agreement tended to be higher for UVC versus UAC position (Rater#1: κ = 0.44 vs. 0.16, respectively, p = 0.08; and #2: κ = 0.56 vs. 0.47, respectively, p = 0.5). Inter-rater agreement was higher on AP versus HDD view for UVC position (κ = 0.6 vs. 0.29, respectively, p = 0.03) and action recommended for UVC (κ = 0.61 and 0.19, respectively, p < 0.001).

Conclusion AP is superior to HDD view for UVC.



Publication History

Received: 17 February 2019

Accepted: 24 September 2019

Article published online:
18 November 2019

© 2019. Thieme. All rights reserved.

Thieme Medical Publishers, Inc.
333 Seventh Avenue, 18th Floor, New York, NY 10001, USA

 
  • References

  • 1 Schlesinger AE, Braverman RM, DiPietro MA. Pictorial essay. Neonates and umbilical venous catheters: normal appearance, anomalous positions, complications, and potential aid to diagnosis. AJR Am J Roentgenol 2003; 180 (04) 1147-1153
  • 2 Hermansen MC, Hermansen MG. Intravascular catheter complications in the neonatal intensive care unit. Clin Perinatol 2005; 32 (01) 141-156
  • 3 Verheij G, Smits-Wintjens V, Rozendaal L, Blom N, Walther F, Lopriore E. Cardiac arrhythmias associated with umbilical venous catheterisation in neonates. BMJ Case Rep 2009; 2009: bcr04.2009.1778
  • 4 Sinha A, Fernandes CJ, Kim JJ, Fenrich Jr AL, Enciso J. Atrial flutter following placement of an umbilical venous catheter. Am J Perinatol 2005; 22 (05) 275-277
  • 5 Murdoch DR, Darlow BA. Handling during neonatal intensive care. Arch Dis Child 1984; 59 (10) 957-961
  • 6 Altman DG. Practical Statistics for Medical Research. 1st ed. London: Chapman & Hall; 1991
  • 7 Baker DH, Berdon WE, James LS. Proper localization of umbilical arterial and venous catheters by lateral roentgenograms. Pediatrics 1969; 43 (01) 34-39
  • 8 Butler GC, Al-Assaf N, Tarrant A, Ryan S, El-Khuffash A. Using lateral radiographs to determine umbilical venous catheter tip position in neonates. Ir Med J 2014; 107 (08) 256-258
  • 9 Verheij GH, Te Pas AB, Witlox RSGM, Smits-Wintjens VEHJ, Walther FJ, Lopriore E. Poor accuracy of methods currently used to determine umbilical catheter insertion length. Int J Pediatr 2010; 2010: 873167
  • 10 Lopriore E, Verheij GH, Walther FJ. Measurement of the ‘shoulder-umbilical’ distance for insertion of umbilical catheters in newborn babies: questionnaire study. Neonatology 2008; 94 (01) 35-37
  • 11 Vali P, Fleming SE, Kim JH. Determination of umbilical catheter placement using anatomic landmarks. Neonatology 2010; 98 (04) 381-386
  • 12 Lin MS, Lim YJ, Ho NK. A quicker simpler method of pre-determination of the length of umbilical artery catheter insertion in Asian babies. J Singapore Paediatr Soc 1989; 31 (1-2): 79-81
  • 13 Sritipsukho S, Sritipsukho P. Simple and accurate formula to estimate umbilical arterial catheter length of high placement. J Med Assoc Thai 2007; 90 (09) 1793-1797
  • 14 Sritipsukho P, Sritipsukho S, Wattanaruangkowit P. Accuracy of the distance between suprasternal notch and superior iliac spine to determine umbilical arterial catheter length. J Med Assoc Thai 2010; 93 (02) 183-186
  • 15 Wright IM, Owers M, Wagner M. The umbilical arterial catheter: a formula for improved positioning in the very low birth weight infant. Pediatr Crit Care Med 2008; 9 (05) 498-501
  • 16 Haase R, Hein M, Thäle V, Vilser C, Merkel N. [Umbilical venous catheters—analysis of malpositioning over a 10-year period]. Z Geburtshilfe Neonatol 2011; 215 (01) 18-22