J Reconstr Microsurg 2020; 36(08): 556-566
DOI: 10.1055/s-0040-1710552
Original Article

The Impact of Indocyanine-Green Fluorescence Angiography on Intraoperative Decision-Making and Postoperative Outcome in Free Flap Surgery

Amir Khosrow Bigdeli
1   Department of Hand, Plastic and Reconstructive Surgery, Burn Center, BG Trauma Center Ludwigshafen, Hand and Plastic Surgery, University of Heidelberg, Heidelberg, Germany
,
Benjamin Thomas
1   Department of Hand, Plastic and Reconstructive Surgery, Burn Center, BG Trauma Center Ludwigshafen, Hand and Plastic Surgery, University of Heidelberg, Heidelberg, Germany
,
Florian Falkner
1   Department of Hand, Plastic and Reconstructive Surgery, Burn Center, BG Trauma Center Ludwigshafen, Hand and Plastic Surgery, University of Heidelberg, Heidelberg, Germany
,
Emre Gazyakan
1   Department of Hand, Plastic and Reconstructive Surgery, Burn Center, BG Trauma Center Ludwigshafen, Hand and Plastic Surgery, University of Heidelberg, Heidelberg, Germany
,
Christoph Hirche
1   Department of Hand, Plastic and Reconstructive Surgery, Burn Center, BG Trauma Center Ludwigshafen, Hand and Plastic Surgery, University of Heidelberg, Heidelberg, Germany
,
Ulrich Kneser
1   Department of Hand, Plastic and Reconstructive Surgery, Burn Center, BG Trauma Center Ludwigshafen, Hand and Plastic Surgery, University of Heidelberg, Heidelberg, Germany
› Institutsangaben
Funding None.

Abstract

Background Reliable perfusion of the distal portions of free flaps is decisive for the reconstructive success. Indocyanine green near-infrared video angiography (ICG-NIR-VA) has been adopted for objective assessment of free flap tissue perfusion but is thus far not used on a routine basis. Therefore, we investigated its intraoperative impact on decision-making and postoperative outcome.

Methods From January 2017 to June 2019, 88 consecutive adipo- or fasciocutaneus free flaps were performed in conjunction with intraoperative ICG-NIR-VA. Free flap tissue perfusion was first assessed clinically and then compared with ICG-NIR-VA findings. Based on the results, the decision for intraoperative trimming of critically perfused flap zones was made. The way of decision-making, flap success, and failure rates as well as intra- and postoperative complication rates were analyzed.

Results The overall free flap success rate was 92.0%. Partial flap necrosis occurred in five cases (5.7%) and total flap necrosis in two cases (2.3%). ICG-NIR-VA aided decision-making and flap design in 34 cases (38.6%) and led to complication-free postoperative courses. When ICG-NIR-VA was relied on (82 out of 88 flaps; 93.2%), there was no unpredicted postoperative tissue necrosis (overestimation). When ICG-NIR-VA was not relied on (6 out of 88 flaps; 6.8%), there were five cases of postoperative partial flap necrosis and one case of uneventful healing (underestimation). The sensitivity of ICG-NIR-VA was 100% (95% confidence interval [CI]: 64.6–100) and the specificity was 98.8% (95% CI: 93.3–100) with a positive predictive value of 87.5% (95% CI: 52.9–99.4) and a negative predictive value of 100% (95% CI: 95.4–100).

Conclusion Intraoperative ICG-NIR-VA objectified free flap perfusion and thus refined surgical decision-making on flap design in all cases. It could always predict tissue necrosis and subjectively improved outcomes in free flap surgery at our institution. Furthermore, it could be easily implemented in intraoperative routine, only adding minimal additional operative time.



Publikationsverlauf

Eingereicht: 03. Januar 2020

Angenommen: 11. April 2020

Artikel online veröffentlicht:
14. Mai 2020

Thieme Medical Publishers
333 Seventh Avenue, New York, NY 10001, USA.

 
  • References

  • 1 Jallali N, Ridha H, Butler PE. Postoperative monitoring of free flaps in UK plastic surgery units. Microsurgery 2005; 25 (06) 469-472
  • 2 Hirigoyen MB, Blackwell KE, Zhang WX, Silver L, Weinberg H, Urken ML. Continuous tissue oxygen tension measurement as a monitor of free-flap viability. Plast Reconstr Surg 1997; 99 (03) 763-773
  • 3 de Weerd L, Mercer JB, Weum S. Dynamic infrared thermography. Clin Plast Surg 2011; 38 (02) 277-292
  • 4 Kneser U, Beier JP, Schmitz M. , et al. Zonal perfusion patterns in pedicled free-style perforator flaps. J Plast Reconstr Aesthet Surg 2014; 67 (01) e9-e17
  • 5 Rauh A, Henn D, Nagel SS, Bigdeli AK, Kneser U, Hirche C. Continuous Video-rate laser speckle imaging for intra- and postoperative cutaneous perfusion imaging of free flaps. J Reconstr Microsurg 2019; 35 (07) 489-498
  • 6 Holm C, Tegeler J, Mayr M, Becker A, Pfeiffer UJ, Mühlbauer W. Monitoring free flaps using laser-induced fluorescence of indocyanine green: a preliminary experience. Microsurgery 2002; 22 (07) 278-287
  • 7 Holm C, Mayr M, Höfter E, Becker A, Pfeiffer UJ, Mühlbauer W. Intraoperative evaluation of skin-flap viability using laser-induced fluorescence of indocyanine green. Br J Plast Surg 2002; 55 (08) 635-644
  • 8 Pestana IA, Coan B, Erdmann D, Marcus J, Levin LS, Zenn MR. Early experience with fluorescent angiography in free-tissue transfer reconstruction. Plast Reconstr Surg 2009; 123 (04) 1239-1244
  • 9 Liu DZ, Mathes DW, Zenn MR, Neligan PC. The application of indocyanine green fluorescence angiography in plastic surgery. J Reconstr Microsurg 2011; 27 (06) 355-364
  • 10 Still J, Law E, Dawson J, Bracci S, Island T, Holtz J. Evaluation of the circulation of reconstructive flaps using laser-induced fluorescence of indocyanine green. Ann Plast Surg 1999; 42 (03) 266-274
  • 11 Bigdeli AK, Gazyakan E, Schmidt VJ. , et al. Indocyanine green fluorescence for free-flap perfusion imaging revisited: advanced decision making by virtual perfusion reality in visionsense fusion imaging angiography. Surg Innov 2016; 23 (03) 249-260
  • 12 Matsui A, Lee BT, Winer JH, Laurence RG, Frangioni JV. Quantitative assessment of perfusion and vascular compromise in perforator flaps using a near-infrared fluorescence-guided imaging system. Plast Reconstr Surg 2009; 124 (02) 451-460
  • 13 Green III JM, Thomas S, Sabino J. , et al. Use of intraoperative fluorescent angiography to assess and optimize free tissue transfer in head and neck reconstruction. J Oral Maxillofac Surg 2013; 71 (08) 1439-1449
  • 14 Lee BT, Matsui A, Hutteman M. , et al. Intraoperative near-infrared fluorescence imaging in perforator flap reconstruction: current research and early clinical experience. J Reconstr Microsurg 2010; 26 (01) 59-65
  • 15 Wu C, Kim S, Halvorson EG. Laser-assisted indocyanine green angiography: a critical appraisal. Ann Plast Surg 2013; 70 (05) 613-619
  • 16 Yoneya S, Saito T, Komatsu Y, Koyama I, Takahashi K, Duvoll-Young J. Binding properties of indocyanine green in human blood. Invest Ophthalmol Vis Sci 1998; 39 (07) 1286-1290
  • 17 Lohman RF, Ozturk CN, Ozturk C, Jayaprakash V, Djohan R. An analysis of current techniques used for intraoperative flap evaluation. Ann Plast Surg 2015; 75 (06) 679-685
  • 18 Xiong L, Gazyakan E, Kremer T. , et al. Free flaps for reconstruction of soft tissue defects in lower extremity: a meta-analysis on microsurgical outcome and safety. Microsurgery 2016; 36 (06) 511-524
  • 19 Kääriäinen M, Halme E, Laranne J. Modern postoperative monitoring of free flaps. Curr Opin Otolaryngol Head Neck Surg 2018; 26 (04) 248-253
  • 20 Li K, Zhang Z, Nicoli F. , et al. Application of indocyanine green in flap surgery: a systematic review. J Reconstr Microsurg 2018; 34 (02) 77-86
  • 21 Lee LN, Smith DF, Boahene KD, Byrne PJ. Intraoperative laser-assisted indocyanine green imaging for objective measurement of the vascular delay technique in locoregional head and neck flaps. JAMA Facial Plast Surg 2014; 16 (05) 343-347
  • 22 Sacks JM, Nguyen AT, Broyles JM, Yu P, Valerio IL, Baumann DP. Near-infrared laser-assisted indocyanine green imaging for optimizing the design of the anterolateral thigh flap. Eplasty 2012; 12: e30
  • 23 Azuma R, Morimoto Y, Masumoto K. , et al. Detection of skin perforators by indocyanine green fluorescence nearly infrared angiography. Plast Reconstr Surg 2008; 122 (04) 1062-1067
  • 24 Fichter AM, Ritschl LM, Georg R. , et al. Effect of segment length and number of osteotomy sites on cancellous bone perfusion in free fibula flaps. J Reconstr Microsurg 2019; 35 (02) 108-116
  • 25 Smit JM, Negenborn VL, Jansen SM. , et al. Intraoperative evaluation of perfusion in free flap surgery: a systematic review and meta-analysis. Microsurgery 2018; 38 (07) 804-818
  • 26 Yang SF, Wang CM, Ono S, Xu W, Xu KY, Pu LLQ. The value of multidetector row computed tomography angiography for preoperative planning of freestyle pedicled perforator flaps. Ann Plast Surg 2016; 77 (06) 669-673
  • 27 Daigeler A, Schubert C, Hirsch T, Behr B, Lehnhardt M. [Colour duplex sonography and “power-duplex” in perforator surgery - improvement of patients safety by efficient planning]. Handchir Mikrochir Plast Chir 2018; 50 (02) 101-110
  • 28 Ludolph I, Horch RE, Arkudas A, Schmitz M. Enhancing safety in reconstructive microsurgery using intraoperative indocyanine green angiography. Front Surg 2019; 6: 39