Open Access
CC BY-NC-ND 4.0 · Journal of Clinical Interventional Radiology ISVIR 2020; 4(03): 154-158
DOI: 10.1055/s-0040-1721534
Original Article

A Validation Study of Liver Volumetry Estimation by a Semiautomated Software in Patients Undergoing Hepatic Resections

Authors

  • Suyash S. Kulkarni

    1   Interventional Radiology, Department of Radio-Diagnosis, Tata Memorial Hospital, Tata Memorial Centre, Mumbai, Maharashtra, India
    2   Homi Bhabha National Institute, Mumbai, India
  • Nitin Sudhakar Shetty

    1   Interventional Radiology, Department of Radio-Diagnosis, Tata Memorial Hospital, Tata Memorial Centre, Mumbai, Maharashtra, India
    2   Homi Bhabha National Institute, Mumbai, India
  • Kunal B. Gala

    1   Interventional Radiology, Department of Radio-Diagnosis, Tata Memorial Hospital, Tata Memorial Centre, Mumbai, Maharashtra, India
    2   Homi Bhabha National Institute, Mumbai, India
  • Shraddha Patkar

    2   Homi Bhabha National Institute, Mumbai, India
    3   Gastrointestinal and HPB Surgery, Department of Surgical Oncology, Tata Memorial Hospital, Tata Memorial Centre, Mumbai, Maharashtra, India
  • Amrita Narang

    1   Interventional Radiology, Department of Radio-Diagnosis, Tata Memorial Hospital, Tata Memorial Centre, Mumbai, Maharashtra, India
    2   Homi Bhabha National Institute, Mumbai, India
  • Ashwin M. Polnaya

    4   Department of Radio-Diagnosis and Imaging, A. J. Institute of Medical Science and Research Centre, Mangalore, Karnataka, India
  • Sushil Patil

    1   Interventional Radiology, Department of Radio-Diagnosis, Tata Memorial Hospital, Tata Memorial Centre, Mumbai, Maharashtra, India
  • Neeraj G. Shetty

    1   Interventional Radiology, Department of Radio-Diagnosis, Tata Memorial Hospital, Tata Memorial Centre, Mumbai, Maharashtra, India
    2   Homi Bhabha National Institute, Mumbai, India
  • Falguni Hota

    1   Interventional Radiology, Department of Radio-Diagnosis, Tata Memorial Hospital, Tata Memorial Centre, Mumbai, Maharashtra, India
    2   Homi Bhabha National Institute, Mumbai, India
  • Mahesh Goel

    2   Homi Bhabha National Institute, Mumbai, India
    3   Gastrointestinal and HPB Surgery, Department of Surgical Oncology, Tata Memorial Hospital, Tata Memorial Centre, Mumbai, Maharashtra, India

Abstract

Purpose The purpose of this study was to validate the use of a semiautomated software for liver volumetry preoperatively by comparing it with the volume of resected specimen in patients undergoing hepatic resections.

Materials and Methods This is a single-center retrospective study of patients who underwent estimation of future liver remnant (FLR) using Myrian XP-Liver which is a semiautomated software for hepatectomy. The estimated resection volume, which is the sum of volume of normal liver to be resected and tumor volume, was compared with actual specimen weight to calculate the accuracy of the software. The statistical analysis was performed with SPSS software version 24.

Results Data on FLR estimation using the semiautomated software was available for 200 out of 388 patients who underwent formal hepatic resections. The median resected volume of surgical specimen was 650 mL (interquartile range [IQR] 364–950), while the median estimated volume using the Myrian software was 617 mL (IQR 362–979). There was significant correlation between estimated resection volume calculated using the semiautomated method and actual specimen weight (p-value < 0.0001) with the Spearman’s correlation value of 0.956.

Conclusion The estimated volume of liver to be resected as calculated by the semiautomated software was accurate and correlated significantly with the volume of resected specimen, and hence, the estimation of FLR volume may likely correlate with the true postoperative residual liver volume. In addition, the software-based liver segmentation, FLR estimation, and color-coded three-dimensional images provide a clear road map to the surgeon to facilitate safe resection.



Publication History

Article published online:
24 December 2020

© 2020. Indian Society of Vascular and Interventional Radiology. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial-License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/).

Thieme Medical and Scientific Publishers Pvt. Ltd.
A-12, 2nd Floor, Sector 2, Noida-201301 UP, India