Background

Silicone oil (SO) is an effective intraocular tamponade used in treating complex retinal detachments. In aphakic eyes, the use of SO may lead to corneal decompensation and glaucoma if the oil remains in contact with the corneal endothelium and the trabecular meshwork [1], [2]. In aphakic eyes with an intact iris, an inferior peripheral iridectomy effectively prevents prolapse of SO into the anterior chamber, thereby preventing keratopathy and glaucoma. However, in aphakic eyes with iris loss SO was considered a relative contraindication because it usually enters the anterior chamber with a very high risk of the development corneal complications. The use of oil tamponades has also been eschewed traditionally in the presence of glaucoma drainage shunts because of the risk of silicone oil migration and obstruction of the shunts.

The purpose of our article is to describe a novel surgical technique which can prevent SO from migrating into the anterior chamber and thus occluding the draining shunts in aphakic and iniridic eyes.

 
  • References

  • 1 Sternberg P, Hatchell DL, Foulks GN et al. The effect of silicone oil on the cornea. Arch Ophthalmol 1985; 103: 90-94
  • 2 Choi WC, Choi SK, Lee JH. Silicone oil keratopathy. Korean J Ophthalmol 1993; 7: 65-69
  • 3 Heimann K, Konen W. Artificial iris diaphragm and silicone oil surgery. Retina 1992; 12 (Suppl. 03) S90-S94
  • 4 Wiedemann P, Konen W, Heimann K. Reconstruction of the anterior and posterior segment of the eye after massive injury. Ger J Ophthalmol 1994; 3: 84-89
  • 5 Thumann G, Kirchhof B, Bartzschmidt K et al. The artificial iris diaphragm for vitreoretinal silicone oil surgery. Retina 1997; 17: 330-337
  • 6 TorresI RJ, Luchini A. TorresIII RJ et al. Iris prosthesis in traumatic aniridia as an attempt to control refractory glaucoma induced by silicone oil in the anterior chamber: case report. Arq Bras Oftalmol 2005; 68: 389-392
  • 7 Gentile RC, Eliott D. Silicone oil retention sutures in aphakic eyes with iris loss. Arch Ophthalmol 2010; 128: 1596-1599
  • 8 Barak Y, Gambrell JD, Tezel TH. Modification of silicone oil retention sutures in aphakic eyes with iris loss. Arch Ophthalmol 2012; 130: 1231-1232
  • 9 Thommen F, Gallaire F, Psaltis D et al. Modified McCannel iridoplasty simulating basal iridectomy for silicone oil tamponade in aphakia and partial aniridia. Klin Monatsbl Augenheilkd 2014; 231: 418-420
  • 10 de Gennes PG, Brochard-Wyart F, Quéré D. Capillarity and Wetting Phenomena: Drops, Bubbles, Pearls, Waves. New York, USA: Springer; 2006