Abstract
Purpose: The working group for abdominal imaging within the German Roentgen Society (DRG) performed an online survey amongst radiologist concerning the current status of techniques for abdominal imaging. The results of this survey were compared with the most recent guidelines.
Materials and Methods: We performed an online survey open for all members of the DRG during a 76-day period with 65 questions and an overall estimated time for finishing the questionnaire of 15 minutes concerning technical specifications for abdominal radiological imaging. The results were evaluated using descriptive statistics.
Results: 90 of all participants, who filled out the survey covering more than 80 % of the questions, were included in the statistical evaluation. 27 % of all participants were registered radiologists while 73 % represented radiologists working in a hospital. Most participants worked in a managerial position. The participants gave detailed information regarding the radiological techniques used in dedicated organ systems (esophagus, stomach, pancreas, liver, small intestines, colon) regarding acquired contrast phases and oral and intravenous administration of contrast medium.
Conclusion: The results confirm that most radiologists participating in this survey perform their examinations and choose their modalities in conformity with the current existing clinical guidelines. Because most clinical guidelines do not specify radiological examinations in detail, there is a noteworthy heterogeneity of the acquired contrast phases and major divergence in terms of technical parameters. Therefore a joint radiological effort should be initiated for developing and publishing updated radiological parameters for abdominal imaging.
Key Points:
• In German speaking countries indications for abdominal radiological examinations are performed with a high compliance to published guidelines.
• There is a significant heterogeneity regarding the acquisition of different contrast phases for parenchymal abdominal organs.
• There is an urgent need to publish radiological recommendations and guidelines based on current radiological literature for radiological abdominal imaging.
Citation Format:
• Schreyer AG, Wessling J, Grenacher L. Versorgungsrealität vs. leitliniengerechte Bildgebung in der Abdominalradiologie im deutschsprachigen Raum: Ergebnisse einer Online-Umfrage. Fortschr Röntgenstr 2016; 188: 1 – 12
Zusammenfassung
Ziel: In einer Online-Umfrage der Arbeitsgemeinschaft Abdominal- und Gastrointestinaldiagnostik der Deutsche Röntgengesellschaft (DRG) sollte ein aktuelles Abbild der gegenwärtig durchgeführten abdominalradiologischen Untersuchungstechniken in Deutschland erstellt und die Ergebnisse den aktuellen Leitlinien zu diesen Themenbereichen gegenübergestellt und kritisch bewertet werden.
Material und Methoden: Den Mitgliedern der DRG, die zu der Umfrage in Newslettern und E-mails eingeladen wurden, stand für 76 Tage eine Online-Umfrage mit insgesamt 65 Fragen und einer Bearbeitungszeit von über 15 Minuten pro Fragebogen zur technischen Durchführung von abdominalradiologischen Fragestellungen offen. Die Ergebnisse der Umfrage wurden mit deskriptiven statistischen Methoden ausgewertet.
Ergebnisse: Insgesamt beantworteten 90 Teilnehmer die Fragebogen über 80 %, die für die Auswertung berücksichtigt werden konnten. Die Umfrage wurde von 27 % niedergelassenen- und 73 % Klinikradiologen durchgeführt, wobei die meisten Teilnehmer in leitenden Positionen waren. Eingeteilt nach Organregionen (Ösophagus, Magen, Pankreas, Leber, Dünndarm, Dickdarm) wurden Angaben zu präferierten akquirierten Kontrastmittelphasen, Arten der oralen und intravenösen Kontrastierung und Auswertemöglichkeiten gemacht.
Schlussfolgerung: Die Ergebnisse der Umfrage zeigen, dass die meisten befragten Radiologen eine leitlinienkonforme Untersuchungstechnik verwenden, wobei die Mehrheit der Leitlinien keinerlei konkrete Angaben zur radiologisch technischen Untersuchungsdurchführung machen. Daher fallen eine beträchtliche Heterogenität der akquirierten Kontrastmittelphasen sowie eine Diversität der möglichen technischen Parameter auf. Es sollte daher angestrebt werden, eine aktuelle evidenzbasierte Empfehlungszusammenstellung für radiologische Untersuchungen zu entwickeln und zu erstellen.
-
Literatur
- 1 Schreyer AG, Wessling J, Kinner S et al. Aktuelle Schwerpunkte und Literatur der Abdominalradiologie im deutschsprachigen Raum – Teil 1: Gastrointestinaltrakt. Fortschr Röntgenstr 2015; in press
- 2 Grenacher L, Juchems M, Holzapfel K et al. Aktuelle Schwerpunkte und Literatur der Abdominalradiologie im deutschsprachigen Raum – Teil 2: Parenchymatöse Oberbauchorgane. Fortschr Röntgenstr 2015; in press
- 3 Schleder S, Dendl LM, Pawlik M et al. MR enterography sequence evaluation for patients with Crohn's disease. Fortschr Röntgenstr 2013; 185: 440-445
- 4 Silva AC, Evans JM, McCullough AE et al. MR imaging of hypervascular liver masses: a review of current techniques. Radiographics 2009; 29: 385-402
- 5 Tirkes T, Menias CO, Sandrasegaran K. MR imaging techniques for pancreas. Radiol Clin North Am 2012; 50: 379-393
- 6 Yao XZ, Kuang T, Wu L et al. Comparison of diffusion-weighted MRI acquisition techniques for normal pancreas at 3.0 Tesla. Diagn Interv Radiol 2014; 20: 368-373
- 7 Leitlinien. AdWMFA-SK. AWMF-Regelwerk „Leitlinien“. In. 2012 1. Auflage ed.
- 8 Leifeld L, Germer CT, Bohm S et al. S2k guidelines diverticular disease/diverticulitis. Z Gastroenterol 2014; 52: 663-710
- 9 Schreyer AG, Layer G. S2k Guidlines for Diverticular Disease and Diverticulitis: Diagnosis, Classification, and Therapy for the Radiologist. Fortschr Röntgenstr 2015; DOI: 10.1055/s-0034-1399526.
- 10 Field MJ, Lohr KN. Clinical practice guidlines: Direction for a new program. Wahington (DC): National Academic Press; 1990
- 11 Hugler S. AWMF: more than guideline development. Dtsch Med Wochenschr 2013; 138: 1926-1927
- 12 Kopp I, Muller W, Lorenz W. Guidelines in the AWMF system: position and perspectives. Z Arztl Fortbild Qualitatssich 2003; 97: 733-735
- 13 Seufferlein T, Porzner M, Becker T et al. S3-guideline exocrine pancreatic cancer. Z Gastroenterol 2013; 51: 1395-1440
- 14 Sommer CM, Stampfl U, Kauczor HU et al. National S3 guidelines on hepatocellular carcinoma. Radiologe 2014; 54: 642-653
- 15 Yokoe M, Takada T, Mayumi T et al. Japanese guidelines for the management of acute pancreatitis: Japanese Guidelines 2015. J Hepatobiliary Pancreat Sci 2015; 22: 405-432
- 16 Goldberg DT, Selina; Maly, Tim; Aldrich, Will. 2015 http://www.surveymonkey.com
- 17 Moehler M, Al-Batran SE, Andus T et al. German S3-guideline "Diagnosis and treatment of esophagogastric cancer". Z Gastroenterol 2011; 49: 461-531
- 18 Erturk SM, Mortele KJ, Oliva MR et al. Depiction of normal gastrointestinal anatomy with MDCT: comparison of low- and high-attenuation oral contrast media. Eur J Radiol 2008; 66: 84-87
- 19 Gligorievski A. CT evaluation of gastric lymphoma. Prilozi 2009; 30: 125-138
- 20 Kim HJ, Kim AY, Lee JH et al. Positioning during CT gastrography in patients with gastric cancer: the effect on gastric distension and lesion conspicuity. Korean J Radiol 2009; 10: 252-259
- 21 Huber W, Schmid RM. Diagnosis and treatment of acute pancreatitis. Current recommendations. Internist (Berl) 2011; 52: 823-830, 832
- 22 Tannapfel A, Wittekind C. The current TNM system for gastrointestinal tumors part II. Pathologe 2010; 31: 348-352
- 23 Barral M, Taouli B, Guiu B et al. Diffusion-weighted MR imaging of the pancreas: current status and recommendations. Radiology 2015; 274: 45-63
- 24 Merkle EM, Zech CJ, Bartolozzi C et al. Consensus report from the 7th International Forum for Liver Magnetic Resonance Imaging. Eur Radiol 2015; DOI: 10.1007/s00330-015-3873-2.
- 25 Song do S, Bae SH. Changes of guidelines diagnosing hepatocellular carcinoma during the last ten-year period. Clin Mol Hepatol 2012; 18: 258-267
- 26 Chen N, Motosugi U, Morisaka H et al. Added Value of a Gadoxetic Acid-enhanced Hepatocyte-phase Image to the LI-RADS System for Diagnosing Hepatocellular Carcinoma. Magn Reson Med Sci 2015; DOI: 10.2463/mrms.2014-0149.
- 27 Purysko AS, Remer EM, Coppa CP et al. LI-RADS: a case-based review of the new categorization of liver findings in patients with end-stage liver disease. Radiographics 2012; 32: 1977-1995
- 28 Alvaro D, Cannizzaro R, Labianca R et al. Cholangiocarcinoma: A position paper by the Italian Society of Gastroenterology (SIGE), the Italian Association of Hospital Gastroenterology (AIGO), the Italian Association of Medical Oncology (AIOM) and the Italian Association of Oncological Radiotherapy (AIRO). Dig Liver Dis 2010; 42: 831-838
- 29 Dietrich CF, Cui XW, Boozari B et al. Contrast-enhanced ultrasound (CEUS) in the diagnostic algorithm of hepatocellular and cholangiocellular carcinoma, comments on the AASLD guidelines. Ultraschall in Med 2012; 33: S57-S66
- 30 Iavarone M, Piscaglia F, Vavassori S et al. Contrast enhanced CT-scan to diagnose intrahepatic cholangiocarcinoma in patients with cirrhosis. J Hepatol 2013; 58: 1188-1193
- 31 Rimola J, Forner A, Reig M et al. Cholangiocarcinoma in cirrhosis: absence of contrast washout in delayed phases by magnetic resonance imaging avoids misdiagnosis of hepatocellular carcinoma. Hepatology 2009; 50: 791-798
- 32 Wildner D, Bernatik T, Greis C et al. CEUS in hepatocellular carcinoma and intrahepatic cholangiocellular carcinoma in 320 patients – early or late washout matters: a subanalysis of the DEGUM multicenter trial. Ultraschall in Med 2015; 36: 132-139
- 33 Asayama Y, Yoshimitsu K, Irie H et al. Delayed-phase dynamic CT enhancement as a prognostic factor for mass-forming intrahepatic cholangiocarcinoma. Radiology 2006; 238: 150-155
- 34 Schreyer AG, Ludwig D, Koletzko S et al. Updated German S3-guideline regarding the diagnosis of Crohn's disease – implementation of radiological modalities. Fortschr Röntgenstr 2010; 182: 116-121
- 35 Stallmach A, Hoffmann J, Preiss JC. Updated S3 guideline on diagnosis and treatment of Crohn's disease: up to date or new?. Z Gastroenterol 2014; 52: 1387-1388
- 36 Pox C, Aretz S, Bischoff SC et al. S3-guideline colorectal cancer version 1.0. Z Gastroenterol 2013; 51: 753-854
- 37 Neri E, Halligan S, Hellstrom M et al. The second ESGAR consensus statement on CT colonography. Eur Radiol 2013; 23: 720-729
- 38 Spada C, Stoker J, Alarcon O et al. Clinical indications for computed tomographic colonography: European Society of Gastrointestinal Endoscopy (ESGE) and European Society of Gastrointestinal and Abdominal Radiology (ESGAR) Guideline. Endoscopy 2014; 46: 897-915
- 39 Grenacher L, Schwarz M, Lordick F et al. S3 guideline – diagnosis and treatment of gastric carcinoma: relevance for radiologic imaging. Fortschr Röntgenstr 2012; 184: 706-712
- 40 Schreyer AG, Jung M, Riemann JF et al. S3 guideline for chronic pancreatitis – diagnosis, classification and therapy for the radiologist. Fortschr Röntgenstr 2014; 186: 1002-1008
- 41 Vogl TJ, Al-Nawas B, Beutner D et al. Updated S2K AWMF guideline for the diagnosis and follow-up of obstructive sialadenitis--relevance for radiologic imaging. Fortschr Röntgenstr 2014; 186: 843-846
- 42 Vogl TJ, Schmiegel W, Pox C et al. S3 guideline – Diagnosis and treatment of colorectal carcinoma: relevance for radiologic imaging and interventions. Fortschr Röntgenstr 2013; 185: 699-708