Semin Thromb Hemost 2021; 47(07): 875-884
DOI: 10.1055/s-0041-1729964
Review Article

Rotational Thromboelastometry in Neonates Admitted to a Neonatal Intensive Care Unit: A Large Cross-sectional Study

Rozeta Sokou*
1   Neonatal Intensive Care Unit, “Agios Panteleimon” General Hospital of Nikaia, Piraeus, Greece
,
Andreas G. Tsantes*
2   Laboratory of Haematology and Blood Bank Unit, “Attikon” Hospital, School of Medicine, National and Kapodistrian University of Athens, Athens, Greece
,
Aikaterini Konstantinidi
1   Neonatal Intensive Care Unit, “Agios Panteleimon” General Hospital of Nikaia, Piraeus, Greece
,
Georgios Ioakeimidis
1   Neonatal Intensive Care Unit, “Agios Panteleimon” General Hospital of Nikaia, Piraeus, Greece
,
Maria Lampridou
1   Neonatal Intensive Care Unit, “Agios Panteleimon” General Hospital of Nikaia, Piraeus, Greece
,
Stavroula Parastatidou
1   Neonatal Intensive Care Unit, “Agios Panteleimon” General Hospital of Nikaia, Piraeus, Greece
,
Martha Theodoraki
1   Neonatal Intensive Care Unit, “Agios Panteleimon” General Hospital of Nikaia, Piraeus, Greece
,
Daniele Piovani
3   Department of Biomedical Sciences, Humanitas University, Pieve Emanuele, Milan, Italy
4   IRCCS Humanitas Research Hospital, Rozzano, Milan, Italy
,
Zoe Iliodromiti
5   Neonatal Department, National and Kapodistrian University of Athens, Aretaeio Hospital, Athens, Greece
,
Theodora Boutsikou
5   Neonatal Department, National and Kapodistrian University of Athens, Aretaeio Hospital, Athens, Greece
,
Nicoletta Iacovidou
5   Neonatal Department, National and Kapodistrian University of Athens, Aretaeio Hospital, Athens, Greece
,
Panagiota Douramani
2   Laboratory of Haematology and Blood Bank Unit, “Attikon” Hospital, School of Medicine, National and Kapodistrian University of Athens, Athens, Greece
,
Aristarchos Poulis
2   Laboratory of Haematology and Blood Bank Unit, “Attikon” Hospital, School of Medicine, National and Kapodistrian University of Athens, Athens, Greece
,
Styliani Kokoris
2   Laboratory of Haematology and Blood Bank Unit, “Attikon” Hospital, School of Medicine, National and Kapodistrian University of Athens, Athens, Greece
,
Anastasios G. Kriebardis
6   Laboratory of Hematology, Department of Biomedical Science, School of Health and Caring Science, University of West Attica, Egaleo, Greece
,
Stefanos Bonovas
3   Department of Biomedical Sciences, Humanitas University, Pieve Emanuele, Milan, Italy
4   IRCCS Humanitas Research Hospital, Rozzano, Milan, Italy
,
Argirios E. Tsantes
2   Laboratory of Haematology and Blood Bank Unit, “Attikon” Hospital, School of Medicine, National and Kapodistrian University of Athens, Athens, Greece
› Institutsangaben
Funding None.

Abstract

The aim of the present study was to assess the coagulation profile in neonatal critical illness using rotational thromboelastometry (ROTEM), and to investigate its association with disease severity and its potential prognostic role in this clinical setting. Over a period of 67 months (July 2014–February 2020) 423 critically ill neonates with confirmed or suspected sepsis, perinatal hypoxia, or respiratory distress syndrome, hospitalized in our neonatal intensive care unit were included in the study. Demographic, clinical, and laboratory data were recorded on admission day and arterial blood was analyzed on ROTEM analyzer using the standard extrinsically activated rotational thromboelastometry assay (EXTEM). Neonatal illness severity scores (Modified NEOMOD [Neonatal Multiple Organ Dysfunction] and SNAPPE [Score for Neonatal Acute Physiology with Perinatal Extension]) were calculated at the same time as ROTEM analysis. Mortality during in-hospital stay was the main outcome measure. Multivariable analyses showed that a 10 mm decrease in EXTEM clot amplitude recorded at 10 minutes (A10) is significantly associated with a higher mortality (odds ratio [OR] = 1.69, 95% confidence interval [CI]: 1.33–2.08). Higher modified NEOMOD (OR = 1.36, 95% CI: 1.26–1.47) and higher SNAPPE scores (OR = 1.06, 95% CI: 1.04–1.08) were also associated with increased mortality. The CT and A10 variables demonstrated the best prognostic performance among the EXTEM parameters for mortality (area under the curve [AUC] = 0.78; 95% CI: 0.69–0.86 and AUC = 0.76; 95% CI: 0.66–0.85, respectively), showing an optimal cut-off CT ≥63 seconds and A10 ≤37 mm. Using optimal cut-off values of the EXTEM parameters for prediction of mortality, neonates with CT ≥63 seconds were 7.4 times more likely to die (OR = 7.40, 95% CI: 3.50–15.65), while neonates with A10 ≤37 mm were 5.8 times more likely to die (OR = 5.88, 95% CI: 2.94–12.50). An EXTEM hypocoagulable profile on disease onset was shown to be an independent risk factor for in-hospital mortality in neonatal critical illness.

Authors' Contributions

R.S. and A.E.T. conceived the study. All authors contributed to the design of the study protocol. R.S., A.K., G.I., M.L., S.P., Z.I., T.B., N.I., M.T.H., P.D., A.P., and S.K. conducted the work and collected the data. A.G.T., S.B., and D.P. performed the statistical analysis. All the authors contributed to the interpretation of data for the work. R.S., A.G.T., and A.E.T. drafted the manuscript. All authors critically revised the paper for important intellectual content and approved the final version to be published.


Ethical Approval

The study protocol was approved by the Institutional Review Board of Nikaia General Hospital (July 17, 2014, 32/3). Informed consent has been obtained by parents or guardians of enrolled neonates.


* Both authors contributed equally to the study.


Supplementary Material



Publikationsverlauf

Artikel online veröffentlicht:
15. Juni 2021

© 2021. Thieme. All rights reserved.

Thieme Medical Publishers, Inc.
333 Seventh Avenue, 18th Floor, New York, NY 10001, USA

 
  • References

  • 1 Mallett SV, Cox DJ. Thrombelastography. Br J Anaesth 1992; 69 (03) 307-313
  • 2 Sivula M, Pettilä V, Niemi TT, Varpula M, Kuitunen AH. Thromboelastometry in patients with severe sepsis and disseminated intravascular coagulation. Blood Coagul Fibrinolysis 2009; 20 (06) 419-426
  • 3 Collins PW, Macchiavello LI, Lewis SJ. et al. Global tests of haemostasis in critically ill patients with severe sepsis syndrome compared to controls. Br J Haematol 2006; 135 (02) 220-227
  • 4 Daudel F, Kessler U, Folly H, Lienert JS, Takala J, Jakob SM. Thromboelastometry for the assessment of coagulation abnormalities in early and established adult sepsis: a prospective cohort study. Crit Care 2009; 13 (02) R42
  • 5 Adamzik M, Langemeier T, Frey UH. et al. Comparison of thrombelastometry with simplified acute physiology score II and sequential organ failure assessment scores for the prediction of 30-day survival: a cohort study. Shock 2011; 35 (04) 339-342
  • 6 Ostrowski SR, Windeløv NA, Ibsen M, Haase N, Perner A, Johansson PI. Consecutive thrombelastography clot strength profiles in patients with severe sepsis and their association with 28-day mortality: a prospective study. J Crit Care 2013; 28 (03) 317.e1-317.e11
  • 7 Sokou R, Konstantinidi A, Stefanaki C. et al. Thromboelastometry: studying hemostatic profile in small for gestational age neonates—a pilot observational study. Eur J Pediatr 2019; 178 (04) 551-557
  • 8 Lampridou M, Sokou R, Tsantes AG. et al. ROTEM diagnostic capacity for measuring fibrinolysis in neonatal sepsis. Thromb Res 2020; 192: 103-108
  • 9 Sokou R, Giallouros G, Konstantinidi A. et al. Thromboelastometry for diagnosis of neonatal sepsis-associated coagulopathy: an observational study. Eur J Pediatr 2018; 177 (03) 355-362
  • 10 Konstantinidi A, Sokou R, Tsantes AG. et al. Thromboelastometry variables in neonates with perinatal hypoxia. Semin Thromb Hemost 2020; 46 (04) 428-434
  • 11 Cetinkaya M, Köksal N, Özkan H. A new scoring system for evaluation of multiple organ dysfunction syndrome in premature infants. American J Crit Care 2012; 21 (05) 328-337
  • 12 Richardson DK, Corcoran JD, Escobar GJ, Lee SK. SNAP-II and SNAPPE-II: simplified newborn illness severity and mortality risk scores. J Pediatr 2001; 138 (01) 92-100
  • 13 Tarnow-Mordi W, Ogston S, Wilkinson AR. et al. Predicting death from initial disease severity in very low birthweight infants: a method for comparing the performance of neonatal units. BMJ 1990; 300 (6740): 1611-1614
  • 14 Martin R. Pathophysiology, Clinical Manifestations, and Diagnosis of Respiratory Distress Syndrome in the Newborn. In: Garcia-Prats JA. ed. Waltham MA; UpToDate; 2020
  • 15 Sokou R, Foudoulaki-Paparizos L, Lytras T. et al. Reference ranges of thromboelastometry in healthy full-term and pre-term neonates. Clin Chem Lab Med 2017; 55 (10) 1592-1597
  • 16 Pakvasa MA, Winkler AM, Hamrick SE, Josephson CD, Patel RM. Observational study of haemostatic dysfunction and bleeding in neonates with hypoxic-ischaemic encephalopathy. BMJ Open 2017; 7 (02) e013787
  • 17 Peker E, Akbayram S, Geylani H, Dogan M, Kirimi E. Global fibrinolytic capacity in neonatal sepsis. Clin Appl Thromb Hemost 2011; 17 (06) E64-E69
  • 18 Yurdakök M, Korkmaz A, Kirazli S, Aygün C, Yigit S. Global fibrinolytic capacity in early respiratory distress syndrome: a pilot study. Am J Hematol 2002; 69 (04) 255-257
  • 19 Müller MC, Meijers JCM, Vroom MB, Juffermans NP. Utility of thromboelastography and/or thromboelastometry in adults with sepsis: a systematic review. Crit Care 2014; 18 (01) R30
  • 20 Brenner T, Schmidt K, Delang M. et al. Viscoelastic and aggregometric point-of-care testing in patients with septic shock—cross-links between inflammation and haemostasis. Acta Anaesthesiol Scand 2012; 56 (10) 1277-1290
  • 21 Levi M, Meijers JC. DIC: which laboratory tests are most useful. Blood Rev 2011; 25 (01) 33-37
  • 22 Levi M, Ten Cate H. Disseminated intravascular coagulation. N Engl J Med 1999; 341 (08) 586-592
  • 23 Revel-Vilk S. The conundrum of neonatal coagulopathy. Hematology (Am Soc Hematol Educ Program) 2012; 2012: 450-454