Semin intervent Radiol 2021; 38(04): 504-508
DOI: 10.1055/s-0041-1735611
Back to the Basics

Understanding the Basics of Commonly Used Wires in Interventional Radiology

Mithil B. Pandhi
1   Department of Radiology, University of Illinois Hospital and Health Sciences System, Chicago, Illinois
,
Ravi Tyagi
1   Department of Radiology, University of Illinois Hospital and Health Sciences System, Chicago, Illinois
,
Divya Surabhi
1   Department of Radiology, University of Illinois Hospital and Health Sciences System, Chicago, Illinois
,
Ketan Y. Shah
1   Department of Radiology, University of Illinois Hospital and Health Sciences System, Chicago, Illinois
› Institutsangaben

The interventional radiologist's (IR's) armamentarium consists of an array of wires, each with a unique set of design properties and functional characteristics that make the instrument suitable for a particular procedure. Operators select wires based on personal preferences generated through experience; however, an understanding of general principles is paramount for both trainees and seasoned IRs, as device properties can guide procedural planning and intraprocedural troubleshooting.



Publikationsverlauf

Artikel online veröffentlicht:
07. Oktober 2021

© 2021. Thieme. All rights reserved.

Thieme Medical Publishers, Inc.
333 Seventh Avenue, 18th Floor, New York, NY 10001, USA

 
  • References

  • 1 Kaufman JA, Lee MJ. Vascular and Interventional Radiology: The Requisites. 2nd ed. Saunders; 2013
  • 2 Mauro MA. Image-Guided Interventions. Expert Radiology Series. 2nd ed.. Philadelphia, PA: Saunders/Elsevier; 2014
  • 3 Schröder J. Peripheral Vascular Interventions: An Illustrated Manual. New York: Thieme; 2013
  • 4 Kido DK, King PD, Manzione JV, Simon JH. The role of catheters and guidewires in the production of angiographic thromboembolic complications. Invest Radiol 1988; 23 (Suppl. 02) S359-S365
  • 5 Lee KH, Han JK, Byun Y. et al. Heparin-coated angiographic catheters: an in vivo comparison of three coating methods with different heparin release profiles. Cardiovasc Intervent Radiol 2004; 27 (05) 507-511
  • 6 Raininko R, Söder H. Clot formation in angiographic catheters–an in vitro comparative study. Effects of heparin and protein coating of the catheter. Acta Radiol 1993; 34 (01) 78-82
  • 7 Huang SY, Engstrom BI, Lungren MP, Kim CY. Management of dysfunctional catheters and tubes inserted by interventional radiology. Semin Intervent Radiol 2015; 32 (02) 67-77
  • 8 Leach KR, Kurisu Y, Carlson JE. et al. Thrombogenicity of hydrophilically coated guide wires and catheters. Radiology 1990; 175 (03) 675-677
  • 9 Rosen LE, Singh RI, Mahon B. Myocardial hydrophilic polymer emboli following cardiac catheterization: a case report and literature review. Cardiovasc Pathol 2014; 23 (03) 175-177
  • 10 Grundeken MJ, Li X, Kurpershoek CE. et al. Distal embolization of hydrophilic-coating material from coronary guidewires after percutaneous coronary interventions. Circ Cardiovasc Interv 2015; 8 (02) e001816
  • 11 Nakao N, Miura K, Takayasu Y, Uchida H. Tip-deflecting wire for percutaneous transhepatic portography. Radiology 1982; 143 (01) 258
  • 12 Sista AK, Vedantham S, Kaufman JA, Madoff DC. Endovascular interventions for acute and chronic lower extremity deep venous disease: state of the art. Radiology 2015; 276 (01) 31-53
  • 13 Patterson RB, Fowl RJ, Lubbers DJ, Vu DN, Kempczinski RF. Repositioning of partially dislodged Greenfield filters from the right atrium by use of a tip deflection wire. J Vasc Surg 1990; 12 (01) 70-72
  • 14 Nemcek Jr AA, Vogelzang RL. Modified use of the tip-deflecting wire in manipulation of foreign bodies. AJR Am J Roentgenol 1987; 149 (04) 777-779
  • 15 Morris DC, Scott IR, Jamieson WR. Pacemaker electrode repositioning using the loop-snare technique. Pacing Clin Electrophysiol 1989; 12 (06) 996-999