Z Gastroenterol 2016; 54(07): 634-641
DOI: 10.1055/s-0042-100284
Originalarbeit
© Georg Thieme Verlag KG Stuttgart · New York

Versiegelung der Leberresektionsfläche mit Gewebsklebematerialien bewirkt keine weitere Verbesserung adäquater Chirurgie

Sealing of the hepatic resection area using hemostat devices does not improve results of adequate surgery
M. Petersen
1   Klinik für Allgemein-, Viszeral- und Gefäßchirurgie, Universitätsklinikum Magdeburg A.ö.R., Magdeburg, Germany
,
R. Steinert
2   Klinik für Allgemein- und Viszeralchirurgie, St Josefs Krankenhaus, Salzkotten, Germany
,
O. Jannasch
3   Klinik für Allgemein- & Viszeralchirurgie, AMEOS Klinikum, Haldensleben, Germany
,
M. Venerito
4   Klinik für Gastroenterologie, Hepatologie und Infektiologie, Universitätsklinikum Magdeburg A.ö.R., Magdeburg, Germany
,
C. Meissner
5   Klinik für Allgemein- und Viszeralchirurgie, Klinikum Magdeburg gGmbH, Magdeburg, Germany
,
S. Kropf
6   Institut für Biometrie und Medizinische Informatik, Universitätsklinikum Magdeburg A.ö.R., Magdeburg, Germany
,
R. Albrecht
7   Klinik für Viszeral- & Gefäßchirurgie, HELIOS Klinikum, Aue, Germany
,
H. Lippert
8   AN-Institut für Qualitätssicherung in der Operativen Medizin, Otto-von-Guericke-Universität, Magdeburg, Germany
,
F. Meyer
1   Klinik für Allgemein-, Viszeral- und Gefäßchirurgie, Universitätsklinikum Magdeburg A.ö.R., Magdeburg, Germany
› Author Affiliations
Further Information

Publication History

09 July 2015

07 January 2016

Publication Date:
18 July 2016 (online)

Zusammenfassung

Ziel: Bei Leberresektionen besteht ein hoher Qualitätsmaßstab. Besonderes Interesse gilt der Vermeidung postoperativer Blutungen oder Galleleckagen. Ermittlung, ob Gewebsklebematerialien das „Outcome“, insbesondere bei Risikopatienten, verbessern können mittels klinischer, prospektiver, unverblindeter Unicenter-Observationsstudie an einer unselektierten Patientenkohorte.

Methode: Alle konsekutiven Patienten (Durchschnittsalter: 60,5 [Spannbreite: 17 – 96] Jahre) mit Leberresektionen (ntotal = 770) wurden prospektiv über 10 Jahre in einer computerbasierten Datei an einem Universitätsklinikum dokumentiert. In die retrospektive Auswertung hinsichtlich des Einflusses der im Operations(OP-)alltag entschiedenen Verwendung von Gewebsklebematerialien wurden 541 (nbereinigt) Patienten ausgewertet (Tissucol® n = 59/Tachocomb® n = 202/Kombination n = 55). Primäre Zielgrößen waren Drainagevolumen, Entzündungsparameter und spezifische Komplikationsrate.

Ergebnisse: Häufigste Resektionsart waren atypische Resektionen (n = 192) und anatomische Monosegmentresektionen (n = 90). Am seltensten wurden Trisegmentresektionen durchgeführt (n = 38). Eine präoperative Gewichtsabnahme sowie die Resektionsart waren unabhängige Einflussfaktoren für die Verwendung additiver Klebematerialien (Trend: ASA, Zirrhose). Die Menge des Drainagevolumens wurde signifikant durch die Faktoren: ASA-Klassifikation, Geschlecht, Karnofsky-Index und Resektionsart beeinflusst (angezeigt durch verteilungsunabhängige Tests wie χ2; U-Test [Mann/Whitney]; H-Test [Kruskal-Willis]; Korrelationskoeffizient nach Spearman). Ohne Berücksichtigung dieser Parameter war die Verwendung von Klebematerial durch vermehrtes Drainagevolumen gekennzeichnet (Negativkontrolle < Tissucol = Tachocomb < Kombination). Auch mittels Varianzanalyse wurde ermittelt, dass Klebematerial keine Verminderung, sondern eher eine Erhöhung des Drainagevolumens erbrachte. In der Kohorte mit Verwendung von Klebematerialien zeigte sich eine ausgeprägtere Leukozytose. Bezüglich der spezifischen Komplikationen wie Nachblutung, Gallefistel und subhepatischem Abszess konnte keine signifikant verringerte Rate durch Versiegelungsmaterial erreicht werden.

Schlussfolgerung: Adäquate Chirurgie bei der Versorgung der Leberresektionsfläche konnte, gemessen am Drainagevolumen, durch Gewebsklebematerialien nicht weiter optimiert werden. Andererseits ist deren Einsatz mit einer verstärkten inflammatorischen Reaktion verbunden. Ob diese durch Besonderheiten des Patientenklientels, bei denen Versiegelungsmaterial unter Alltagsentscheidung angewendet wurde, oder durch reaktive Entzündung auf Fremdmaterial bedingt ist, lässt sich anhand der Studienergebnisse nicht klären.

Abstract

Purpose: In hepatic resections, there has been a high quality demand. The aim of this systematic clinical, prospective, unblinded unicenter observational study with two arms in an unselected patient cohort was to investigate whether hemostat device can significantly improve outcome in resective liver surgery, in particular, in high risk patients.

Methods: All consecutive patients (mean age, 60.5 [range, 17 – 96] years) who underwent hepatic resection (ntotal = 770) were prospectively documented in a computer-based registry at a university hospital (tertiary center) over a time period of 10 years and retrospectively evaluated specifically with regard to the use (-/+; in daily practice and intraoperative decision-making) of hemostat device (Tissucol®, n = 59/Tachocomb®, n = 202/combination, n = 55) indicated (among others) by drainage volume, inflammatory parameters and rate of specific complications (nvalidated = 541 [100 %]).

Results: Most frequently, (a-)/typical segmental resections were used: n = 192/90 (3-segment resection, only n = 38). 1) For the assignment of patients to the two different groups (-/+ hemostat device), weight loss and type of resection were found as significant factors (trend: ASA, cirrhosis), for the amount of drainage volume, ASA, sex, Karnofsky Performance Scale and also type of resections using independent distributed statistical tests (such as χ2, U test [Mann/Whitney]; H test [Kruskal-Willis]; correlation coefficient by Spearman) – no impact: smoking, diabetes, BMI, ethanol. 2) Not taking into account these parameters, the use of hemostat device was characterized by an increased drainage volume (negative control < Tissucol = Tachocomb < combination). 3) Using multifactorial analysis of variance, it was found even under correction by the factors with significant impact elucidated in the single test that the application of hemostat device onto the hepatic resection area resulted unexpectedly rather in an increase than a decrease of the drainage volume but 4) under accompanying more pronounced increase of the white blood cell count (leucocytosis). 5) General and specific complications such as postoperative bleeding, biliary fistula and subhepatic abscess were not further lowered in a significant manner using hemostat device.

Conclusion: Adequate surgery in the operative management of hepatic resection area cannot further be improved or optimized using hemostat device. In this context, drainage volume may not be considered a sufficient rather an orienting parameter. However, there is an inflammatory response detectable most likely indicated by a(n un-)specific effusion and increase of white blood cell count, which can be interpreted as a) being characteristic for the problematic group of patients, in whom hemostat device was decided to be useful and was finally used in daily prectice, or b) reactive inflammation to foreign material.

 
  • Literatur

  • 1 Bektas H, Nadalin S, Szabo I et al. Hemostatic efficacy of latest-generation fibrin sealant after hepatic resection: a randomized controlled clinical study. Langenbecks Arch Surg 2014; 399: 837-847
  • 2 Kobayashi S, Nagano H, Marubashi S et al. Fibrin sealant with PGA felt for prevention of bile leakage after liver resection. Hepatogastroenterology 2012; 59: 2564-2568
  • 3 Ruitenbeek K, Ayez N, Verhoef C et al. Safety and efficacy of a novel, dry powder fibrin sealant for hemostasis in hepatic resection. Dig Surg 2014; 31: 422-427
  • 4 Cheang T, Hanna SS, Wright FC et al. Use of a collagen-sealing device in hepatic resection: a comparative analysis to standard resection technique. HPB (Oxford) 2006; 8: 194-199
  • 5 Di Carlo I, Pulvirenti E, Guastella T et al. Parenchymal compression and new devices for hepatic resections: re-visitation of an old technique. Hepatogastroenterology 2011; 58: 980-983
  • 6 Moench C, Bechstein WO, Hermanutz V et al. Comparison of the collagen haemostat Sangustop® versus a carrier-bound fibrin sealant during liver resection; ESSCALIVER-Study. Trials 2010; 11: 1098
  • 7 Moench C, Mihaljevic AL, Hermanutz V et al. Randomized controlled multicenter trial on the effectiveness of the collagen hemostat Sangustop® compared with a carrier-bound fibrin sealant during liver resection (ESSCALIVER study, NCT00918619). Langenbecks Arch Surg 2014; 399: 725-733
  • 8 Baxter Deutschland GmbH. http://www.baxter.de/downloads/fachinformation/tissucol_duo_s_immuno.pdf (letzter Zugriff: 26. 06. 2014)
  • 9 Berrevoet F, de Hemptinne B. Use of Topical Hemostatic Agents during Liver Resection. Dig Surg 2007; 24: 288-293
  • 10 Heise M, Jandt K, Rauchfuss F et al. Management of complications after liver resection. Zentralbl Chir 2010; 135: 112-120
  • 11 Eder F, Meyer F, Nestler G et al. Sealing of the hepatic resection area using fibrin glue reduces significantly amount of postoperative drain fluid. World J Gastroenterol 2005; 11: 5984-5987
  • 12 Köckerling F, Schneider C, Scheidbach H et al. Stellenwert der Fibrinklebung in der Leberchirurgie. In: Köckerling F, (ed.) Leberchirurgie. 1st ed. Heidelberg, Leipzig: Johann Ambrosius Barth; 1999: 103-108
  • 13 Frilling A, Stavrou GA, Mischinger HJ et al. Effectiveness of a new carrier-bound fibrin sealant versus argon beamer as haemostatic agent during liver resection: a randomised prospective trial. Langenbecks Arch Surg 2005; 390: 114-120
  • 14 Noun R, Elias D, Balladur P et al. Fibrin glue effectiveness and tolerance after elective liver resection: a randomized trial. Hepatogastroenterology 1996; 43: 221-224
  • 15 Lang G, Csekeö A, Stamatis G et al. Efficacy and safety of topical application of human fibrinogen/thrombin-coated collagen patch (TachoComb®) for treatment of air leakage after standard lobectomy. Eur J Cardiothorac Surg 2004; 25: 160-166
  • 16 Figueras J, Llado L, Miro M et al. Application of fibrin glue sealant after hepatectomy does not seem justified: results of a randomized study in 300 patients. Ann Surg 2007; 245: 536-542
  • 17 Kraus TW, Mehrabi A, Schemmer P et al. Scientific evidence for application of topical hemostats, tissue glues, and sealants in hepatobiliary surgery. J Am Coll Surg 2005; 200: 418-427
  • 18 Nakajima Y, Shimamura T, Kamiyama T et al. Control of intraoperative bleeding during liver resection: analysis of a questionnaire sent to 231 Japanese hospitals. Surg Today 2002; 32: 48-52
  • 19 Kallinowski F, Pfeil T, Ulbrich W. Qualitätsmanagement in der chirurgischen Intervention – eine prospektive Versorgungsforschungsstudie zu vliesgebundener Gewebeklebung (Tachosil®). Gesundh Ökon Qual Manag 2005; 10: 151-160
  • 20 Hayashibe A, Sakamoto K, Shinbo M et al. New method for prevention of bile leakage after hepatic resection. J Surg Oncol 2006; 94: 57-60
  • 21 Leberchirurgie – Kein klinischer Vorteil durch Fibrinkleber. Zentralbl Chir 2012; 137: 506
  • 22 Pankreaslinksresektion – Senkt ein Fibrinkleber-Vlies die Rate an Pankreasfisteln?. Zentralbl Chir 2013; 38: 5-6
  • 23 Schopf SK, von Ahnen M, von Ahnen T et al. Observations on the use of TachoSil® in cholecystectomy – a multicentre, prospective, single-arm cohort study. Zentralbl Chir 2012; 137: 55-60
  • 24 Öllinger R, Mihaljevic AL, Schuhmacher C et al. A multicentre, randomized clinical trial comparing the Veriset™ haemostatic patch with fibrin sealant for the management of bleeding during hepatic surgery. HPB (Oxford) 2013; 15: 548-558