A 54-year-old man underwent a proximal gastrectomy with partial esophagectomy to treat a carcinoma of the cardia 5 years ago. A persistent postoperative fistula of the esophago-gastric anastomosis occurred, which required a second surgery 4 years ago during which a colon interposition was performed. After surgery, stricture of the esophagus-colonic anastomosis developed 2 cm distal from the upper esophageal sphincter, causing grade 3 dysphagia for which the patient underwent multiple dilations with Savary–Gilliard bougies. As the stenosis was deemed refractory to serial dilations, a biodegradable esophageal stent (BD stent 019-10A-23/18/23-060; SX-ELLA, Hradec Kralove, Czech Republic) was placed 1 year ago ([Fig. 1]).
Although transient improvement was noticed, the patient experienced recurrent dysphagia 1 month later and required further dilations 4 months later. Hence, a 4 cm diabolo-shaped, covered, biliary, self-expandable metallic stent (SEMS; Hanarostent BCF-10-040-180; M.I. Tech Co., Seoul, Korea), 10 mm in diameter and with flares 5 mm long and 24 mm in diameter, was placed under direct and fluoroscopic view ([Fig. 2], [Fig. 3], [Fig. 4]) using a therapeutic channel endoscope (GIF 2T130; Olympus, Tokyo, Japan). The stent was well tolerated and the patient noticed an immediate substantial improvement from grade 3 to grade 1 dysphagia.
The stent was exchanged three more times at 8-week intervals using the proximal lasso for stent removal; increasing improvement in the diameter of the stenosis was observed. The final two procedures were performed under direct view only ([Fig. 5], [Fig. 6], [Video 1], [Video 2]). The patient remained asymptomatic after removal of the final stent.
Quality:
Quality:
Diabolo-shaped stents have important technical advantages for stenoses near the upper esophageal sphincter, as they have shorter and larger flares that limit patient intolerance and prevent migration, respectively. Furthermore, the diameter of the delivery device permits its placement under direct endoscopic view using a therapeutic endoscope, resulting in accurate positioning [1] [2] [3] [4].
Endoscopy_UCTN_Code_TTT_1AO_2AZ
-
References
- 1 Binmoeller KF, Shah J. A novel lumen-apposing stent for transluminal drainage of nonadherent extraintestinal fluid collections. Endoscopy 2011; 43: 337-342
- 2 Gornals JB, De la Serna-Higuera C, Sánchez-Yague A et al. Endosonography-guided drainage of pancreatic fluid collections with a novel lumen-apposing stent. Surg Endosc 2013; 27: 1428-1434
- 3 Itoi T, Binmoeller KF. EUS-guided choledochoduodenostomy by using a biflanged lumen-apposing metal stent. Gastrointest Endosc 2014; 79: 715
- 4 Majumder S, Buttar N, Gostout C et al. Lumen-apposing covered self-expanding metal stent for management of benign gastrointestinal strictures. Endosc Int Open 2016; 04: E96-E101