CC BY 4.0 · Eur J Dent 2023; 17(04): 1114-1119
DOI: 10.1055/s-0042-1758787
Original Article

Marginal Discrepancy of Five Contemporary Dental Ceramics for Anterior Restorations

1   Department of Applied Dental Sciences, Faculty of Applied Medical Sciences, Jordan University of Science and Technology, Irbid, Jordan
,
Muhanad Hatamleh
2   Department of Applied Medical Sciences, Luminus Technical University College, Amman, Jordan
,
Yasmeen Janzeer
1   Department of Applied Dental Sciences, Faculty of Applied Medical Sciences, Jordan University of Science and Technology, Irbid, Jordan
,
Ali Alrahlah
3   Engineer Abdullah Bugshan Research Chair for Dental and Oral Rehabilitation, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
4   Restorative Dental Sciences Department, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
,
Khold Alahadal
4   Restorative Dental Sciences Department, College of Dentistry, King Saud University, Riyadh, Saudi Arabia
› Author Affiliations

Abstract

Objectives This study aimed to compare marginal accuracy of five contemporary all-ceramic crowns indicated for anterior restorations.

Materials and Methods A master die of maxillary central incisor was prepared for all-ceramic crown and duplicated to produce 50 replicas of epoxy resin material. Five ceramic materials were used to mill the crowns (n = 10). All crowns were manufactured following the same digital workflow; same master die, scanning unit and design software, and the recommended manufacturing protocol. Final seating of crown was secured by a small droplet of temporary cement on its incisal edge. Marginal accuracy was evaluated by scanning electronic microscope with a magnification of 300 × . Vertical marginal gap was measured for each crown at predefined four points.

Statistical Analysis One-way analysis of variance was used to test differences between groups and Tukey test was used for multiple comparisons between group combinations. A level of significance at 95% was set for all statistics.

Results The highest mean marginal gap and mean maximum gap calculated were for the e.max CAD crowns (49.2 µm, 87.6 µm), while the lowest values were for the Cercon xt crowns (10.2 µm, 21.7 µm). The mean marginal gap and the mean maximum gap of the e.max CAD crowns were statistically significantly greater than those of all other groups (p < 0.05). However, the differences between all other combinations were insignificant (p > 0.05).

Conclusion Marginal accuracy of lithium disilicate crowns is clinically acceptable. Zirconia and zirconia-reinforced lithium silicate materials can produce a greater level of marginal accuracy compared to lithium disilicate.



Publication History

Article published online:
04 January 2023

© 2023. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/)

Thieme Medical and Scientific Publishers Pvt. Ltd.
A-12, 2nd Floor, Sector 2, Noida-201301 UP, India

 
  • References

  • 1 Bader JD, Rozier RG, McFall Jr WT, Ramsey DL. Effect of crown margins on periodontal conditions in regularly attending patients. J Prosthet Dent 1991; 65 (01) 75-79
  • 2 Felton DA, Kanoy BE, Bayne SC, Wirthman GP. Effect of in vivo crown margin discrepancies on periodontal health. J Prosthet Dent 1991; 65 (03) 357-364
  • 3 Knoernschild KL, Campbell SD. Periodontal tissue responses after insertion of artificial crowns and fixed partial dentures. J Prosthet Dent 2000; 84 (05) 492-498
  • 4 Maske TT, Hollanders ACC, Kuper NK, Bronkhorst EM, Cenci MS, Huysmans MCDNJM. A threshold gap size for in situ secondary caries lesion development. J Dent 2019; 80: 36-40
  • 5 Rekow D, Thompson VP. Near-surface damage–a persistent problem in crowns obtained by computer-aided design and manufacturing. Proc Inst Mech Eng H 2005; 219 (04) 233-243
  • 6 Sailer I, Makarov NA, Thoma DS, Zwahlen M, Pjetursson BE. All-ceramic or metal-ceramic tooth-supported fixed dental prostheses (FDPs)? A systematic review of the survival and complication rates. Part I: single crowns (SCs). Dent Mater 2015; 31 (06) 603-623
  • 7 Kricheldorf F, Bueno CRS, Amaral WDS, Junior JFS, Filho HN. Analysis of vertical marginal discrepancy in feldspathic porcelain crowns manufactured with different CAD/CAM systems: closed and open. Eur J Dent 2018; 12 (01) 123-128
  • 8 Habib SR, Ansari AS, Bajunaid SO, Alshahrani A, Javed MQ. Evaluation of film thickness of crown disclosing agents and their comparison with cement film thickness after final cementation. Eur J Dent 2020; 14 (02) 224-232
  • 9 American Dental Association. ANSI/ADA Specification No. 8 for Zinc Phosphate Cement. Guide to Dental Materials and Devices.. Chicago, IL: American Dental Association; 1970
  • 10 Abdul Hamid NF, Wan Bakar WZ, Ariffin Z. Marginal gap evaluation of metal onlays and resin nanoceramic computer-aided design and computer-aided manufacturing blocks onlays. Eur J Dent 2019; 13 (01) 17-21
  • 11 Papadiochou S, Pissiotis AL. Marginal adaptation and CAD-CAM technology: a systematic review of restorative material and fabrication techniques. J Prosthet Dent 2018; 119 (04) 545-551
  • 12 Boitelle P, Mawussi B, Tapie L, Fromentin O. A systematic review of CAD/CAM fit restoration evaluations. J Oral Rehabil 2014; 41 (11) 853-874
  • 13 Ghodsi S, Alikhasi M, Soltani N. Marginal discrepancy of single implant-supported metal copings fabricated by various CAD/CAM and conventional techniques using different materials. Eur J Dent 2019; 13 (04) 563-568
  • 14 Malchiodi L, Zotti F, Moro T, De Santis D, Albanese M. Clinical and esthetical evaluation of 79 lithium disilicate multilayered anterior veneers with a medium follow-up of 3 years. Eur J Dent 2019; 13 (04) 581-588
  • 15 Zhang Y, Lawn BR. Novel zirconia materials in dentistry. J Dent Res 2018; 97 (02) 140-147
  • 16 Sen N, Isler S. Microstructural, physical, and optical characterization of high-translucency zirconia ceramics. J Prosthet Dent 2020; 123 (05) 761-768
  • 17 Cho YE, Lim YJ, Han JS, Yeo IL, Yoon HI. Effect of Yttria content on the translucency and masking ability of Yttria-stabilized tetragonal zirconia polycrystal. Materials (Basel) 2020; 13 (21) 4726
  • 18 Porojan L, Vasiliu R-D, Bîrdeanu M-I, Porojan S-D. Surface characterization and optical properties of reinforced dental glass-ceramics related to artificial aging. Molecules 2020; 25 (15) 3407
  • 19 Riquieri H, Monteiro JB, Viegas DC, Campos TMB, de Melo RM, de Siqueira Ferreira Anzaloni Saavedra G. Impact of crystallization firing process on the microstructure and flexural strength of zirconia-reinforced lithium silicate glass-ceramics. Dent Mater 2018; 34 (10) 1483-1491
  • 20 Nawafleh NA, Mack F, Evans J, Mackay J, Hatamleh MM. Accuracy and reliability of methods to measure marginal adaptation of crowns and FDPs: a literature review. J Prosthodont 2013; 22 (05) 419-428
  • 21 Contrepois M, Soenen A, Bartala M, Laviole O. Marginal adaptation of ceramic crowns: a systematic review. J Prosthet Dent 2013; 110 (06) 447-454 .e10
  • 22 Kale E, Seker E, Yilmaz B, Özcelik TB. Effect of cement space on the marginal fit of CAD-CAM-fabricated monolithic zirconia crowns. J Prosthet Dent 2016; 116 (06) 890-895
  • 23 Groten M, Axmann D, Pröbster L, Weber H. Determination of the minimum number of marginal gap measurements required for practical in-vitro testing. J Prosthet Dent 2000; 83 (01) 40-49
  • 24 Rinke S, Fornefett D, Gersdorff N, Lange K, Roediger M. Multifactorial analysis of the impact of different manufacturing processes on the marginal fit of zirconia copings. Dent Mater J 2012; 31 (04) 601-609
  • 25 Lee B, Oh KC, Haam D, Lee J-H, Moon H-S. Evaluation of the fit of zirconia copings fabricated by direct and indirect digital scanning procedures. J Prosthet Dent 2018; 120 (02) 225-231
  • 26 Pilo R, Folkman M, Arieli A, Levartovsky S. Marginal fit and retention strength of zirconia crowns cemented by self-adhesive resin cements. Oper Dent 2018; 43 (02) 151-161
  • 27 McLean JW, von Fraunhofer JA. The estimation of cement film thickness by an in vivo technique. Br Dent J 1971; 131 (03) 107-111
  • 28 Riccitiello F, Amato M, Leone R, Spagnuolo G, Sorrentino R. In vitro evaluation of the marginal fit and internal adaptation of zirconia and lithium disilicate single crowns: micro-CT comparison between different manufacturing procedures. Open Dent J 2018; 12: 160-172
  • 29 Yildirim G, Uzun IH, Keles A. Evaluation of marginal and internal adaptation of hybrid and nanoceramic systems with microcomputed tomography: an in vitro study. J Prosthet Dent 2017; 118 (02) 200-207
  • 30 Hasanzade M, Sahebi M, Zarrati S, Payaminia L, Alikhasi M. Comparative evaluation of the internal and marginal adaptations of CAD/CAM endocrowns and crowns fabricated from three different materials. Int J Prosthodont 2021; 34 (03) 341-347
  • 31 Dolev E, Bitterman Y, Meirowitz A. Comparison of marginal fit between CAD-CAM and hot-press lithium disilicate crowns. J Prosthet Dent 2019; 121 (01) 124-128
  • 32 Al Hamad KQ, Al Quran FA, AlJalam SA, Baba NZ. Comparison of the accuracy of fit of metal, zirconia, and lithium disilicate crowns made from different manufacturing techniques. J Prosthodont 2019; 28 (05) 497-503
  • 33 Kwong B, Dudley J. A comparison of the marginal gaps of lithium disilicate crowns fabricated by two different intraoral scanners. Aust Dent J 2020; 65 (02) 150-157
  • 34 Al Hamad KQ, Al Rashdan BA, Al Omari WM, Baba NZ. Comparison of the fit of lithium disilicate crowns made from conventional, digital, or conventional/digital techniques. J Prosthodont 2019; 28 (02) e580-e586
  • 35 Azarbal A, Azarbal M, Engelmeier RL, Kunkel TC. Marginal fit comparison of CAD/CAM crowns milled from two different materials. J Prosthodont 2018; 27 (05) 421-428
  • 36 Gold SA, Ferracane JL, da Costa J. Effect of crystallization firing on marginal gap of CAD/CAM fabricated lithium disilicate crowns. J Prosthodont 2018; 27 (01) 63-66
  • 37 Fraga S, Amaral M, Bottino MA, Valandro LF, Kleverlaan CJ, May LG. Impact of machining on the flexural fatigue strength of glass and polycrystalline CAD/CAM ceramics. Dent Mater 2017; 33 (11) 1286-1297
  • 38 Christensen GJ. Clinical and research advancements in cast-gold restorations. J Prosthet Dent 1971; 25 (01) 62-68
  • 39 Dedmon HW. Disparity in expert opinions on size of acceptable margin openings. Oper Dent 1982; 7 (03) 97-101
  • 40 Holmes JR, Bayne SC, Holland GA, Sulik WD. Considerations in measurement of marginal fit. J Prosthet Dent 1989; 62 (04) 405-408