RSS-Feed abonnieren

DOI: 10.1055/s-0042-1758796
Evaluation of Fitness and Accuracy of Milled and Three-Dimensionally Printed Inlays
Funding This study was supported by Wonkwang University in 2021.
Abstract
Objective This article compares and evaluates the marginal and internal fitness and three-dimensional (3D) accuracy of class II inlays fabricated using Tescera (TS) resin, milling of hybrid and zirconia blocks, and 3D printing with NextDent C&B.
Materials and Methods Fifty-two mesio-occlusal inlays were fabricated using conventional method with TS, milling of Lava Ultimate (LU), milling of Zolid Fx multilayer (ZR), and 3D printing (n = 13 each). The marginal and internal fitness were evaluated at six points in the mesio-distal section of a replica under a digital microscope (160× magnification), and the accuracy was evaluated using 3D software. Analyses were conducted using t-test, one-way analysis of variance (ANOVA) and two-way ANOVA, while Duncan's multiple range test was used for post hoc analyses (α = 0.05).
Results The marginal and internal fitness of the 3D and ZR were significantly superior to that of the TS and LU. For LU, ZR, and 3D, a significant discrepancy between the marginal gap and internal gap was observed (p < 0.05). On evaluating accuracy, trueness was significantly higher in ZR than in TS and LU; precision was significantly higher in 3D and ZR than in TS and LU (p < 0.05).
Conclusion The marginal and internal fitness and the accuracy of TS, ZR, and 3D were within the clinically acceptable range. The marginal and internal fitness and accuracy of 3D were better than those of TS and LU, which are commonly used in dentistry. There is immense potential for using 3D-printed inlays in routine clinical practice.
Financial Interest
The authors do not have any financial interest in the companies whose materials are included in this article.
Publikationsverlauf
Artikel online veröffentlicht:
04. Januar 2023
© 2023. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/)
Thieme Medical and Scientific Publishers Pvt. Ltd.
A-12, 2nd Floor, Sector 2, Noida-201301 UP, India
-
References
- 1 Reymus M, Fabritius R, Keßler A, Hickel R, Edelhoff D, Stawarczyk B. Fracture load of 3D-printed fixed dental prostheses compared with milled and conventionally fabricated ones: the impact of resin material, build direction, post-curing, and artificial aging-an in vitro study. Clin Oral Investig 2020; 24 (02) 701-710
- 2 Bousnaki M, Chatziparaskeva M, Bakopoulou A, Pissiotis A, Koidis P. Variables affecting the fit of zirconia fixed partial dentures: a systematic review. J Prosthet Dent 2020; 123 (05) 686-692.e8
- 3 Lee WS, Lee DH, Lee KB. Evaluation of internal fit of interim crown fabricated with CAD/CAM milling and 3D printing system. J Adv Prosthodont 2017; 9 (04) 265-270
- 4 Patzelt SB, Bishti S, Stampf S, Att W. Accuracy of computer-aided design/computer-aided manufacturing-generated dental casts based on intraoral scanner data. J Am Dent Assoc 2014; 145 (11) 1133-1140
- 5 Keßler A, Hickel R, Ilie N. In vitro investigation of the influence of printing direction on the flexural strength, flexural modulus and fractographic analysis of 3D-printed temporary materials. Dent Mater J 2021; 40 (03) 641-649
- 6 Park SM, Park JM, Kim SK, Heo SJ, Koak JY. Flexural strength of 3D-printing resin materials for provisional fixed dental prostheses. Materials (Basel) 2020; 13 (18) 3970
- 7 Cunali RS, Saab RC, Correr GM. et al. Marginal and internal adaptation of zirconia crowns: a comparative study of assessment. Braz Dent J 2017; 28 (04) 467-473
- 8 Goujat A, Abouelleil H, Colon P. et al. Marginal and internal fit of CAD-CAM inlay/onlay restorations: a systematic review of in vitro studies. J Prosthet Dent 2019; 121 (04) 590-597.e3
- 9 McLean JW, von Fraunhofer JA. The estimation of cement film thickness by an in vivo technique. Br Dent J 1971; 131 (03) 107-111
- 10 Kang SY, Lee HN, Kim JH, Kim WC. Evaluation of marginal discrepancy of pressable ceramic veneer fabricated using CAD/CAM system: additive and subtractive manufacturing. J Adv Prosthodont 2018; 10 (05) 347-353
- 11 Reich S, Gozdowski S, Trentzsch L, Frankenberger R, Lohbauer U. Marginal fit of heat-pressed vs. CAD/CAM processed all-ceramic onlays using a milling unit prototype. Oper Dent 2008; 33 (06) 644-650
- 12 Park SH, Yoo YJ, Shin YJ, Cho BH, Baek SH. Marginal and internal fit of nano-composite CAD/CAM restorations. Restor Dent Endod 2016; 41 (01) 37-43
- 13 Alajaji NK, Bardwell D, Finkelman M, Ali A. Micro-CT evaluation of ceramic inlays: comparison of the marginal and internal fit of five and three axis cam systems with a heat press technique. J Esthet Restor Dent 2017; 29 (01) 49-58
- 14 Homsy FR, Özcan M, Khoury M, Majzoub ZAK. Comparison of fit accuracy of pressed lithium disilicate inlays fabricated from wax or resin patterns with conventional and CAD-CAM technologies. J Prosthet Dent 2018; 120 (04) 530-536
- 15 Paul N, Raghavendra Swamy KN, Dhakshaini MR, Sowmya S, Ravi MB. Marginal and internal fit evaluation of conventional metal-ceramic versus zirconia CAD/CAM crowns. J Clin Exp Dent 2020; 12 (01) e31-e37
- 16 Wu J, Xie H, Sadr A, Chung KH. Evaluation of internal fit and marginal adaptation of provisional crowns fabricated with three different techniques. Sensors (Basel) 2021; 21 (03) 740
- 17 Laurent M, Scheer P, Dejou J, Laborde G. Clinical evaluation of the marginal fit of cast crowns–validation of the silicone replica method. J Oral Rehabil 2008; 35 (02) 116-122
- 18 Al Hamad KQ, Al Quran FA, AlJalam SA, Baba NZ. Comparison of the accuracy of fit of metal, zirconia, and lithium disilicate crowns made from different manufacturing techniques. J Prosthodont 2019; 28 (05) 497-503
- 19 Svanborg P. A systematic review on the accuracy of zirconia crowns and fixed dental prostheses. Biomater Investig Dent 2020; 7 (01) 9-15
- 20 Goujat A, Abouelleil H, Colon P. et al. Mechanical properties and internal fit of 4 CAD-CAM block materials. J Prosthet Dent 2018; 119 (03) 384-389
- 21 Cho JH, Yoon HI, Han JS, Kim DJ. Trueness of the inner surface of monolithic crowns fabricated by milling of a fully sintered (Y, Nb)-TZP block in chairside CAD-CAM system for single-visit dentistry. Materials (Basel) 2019; 12 (19) 3253
- 22 Peters MC, Delong R, Pintado MR, Pallesen U, Qvist V, Douglas WH. Comparison of two measurement techniques for clinical wear. J Dent 1999; 27 (07) 479-485
- 23 Al Hamad KQ, Al-Rashdan RB, Al-Rashdan BA, Baba NZ. Effect of milling protocols on trueness and precision of ceramic crowns. J Prosthodont 2021; 30 (02) 171-176
- 24 Kim KB, Kim JH, Kim WC, Kim HY, Kim JH. Evaluation of the marginal and internal gap of metal-ceramic crown fabricated with a selective laser sintering technology: two- and three-dimensional replica techniques. J Adv Prosthodont 2013; 5 (02) 179-186
- 25 Denkena B, Breidenstein B, Busemann S, Lehr CM. Impact of hard machining on zirconia based ceramics for dental applications. Procedia CIRP 2017; 65: 248-252
- 26 Denry I, Kelly JR. State of the art of zirconia for dental applications. Dent Mater 2008; 24 (03) 299-307
- 27 Bayrak A, Akat B, Ocak M, Kιlιçarslan MA, Özcan M. Micro-computed tomography analysis of fit of ceramic inlays produced with different CAD software programs. Eur J Prosthodont Restor Dent 2021; 29 (03) 29
- 28 Spitznagel FA, Boldt J, Gierthmuehlen PC. CAD/CAM ceramic restorative materials for natural teeth. J Dent Res 2018; 97 (10) 1082-1091
- 29 Türk AG, Sabuncu M, Ünal S, Önal B, Ulusoy M. Comparison of the marginal adaptation of direct and indirect composite inlay restorations with optical coherence tomography. J Appl Oral Sci 2016; 24 (04) 383-390
- 30 Alharbi N, Alharbi S, Cuijpers VMJI, Osman RB, Wismeijer D. Three-dimensional evaluation of marginal and internal fit of 3D-printed interim restorations fabricated on different finish line designs. J Prosthodont Res 2018; 62 (02) 218-226
- 31 Alharbi N, Osman R, Wismeijer D. Effects of build direction on the mechanical properties of 3D-printed complete coverage interim dental restorations. J Prosthet Dent 2016; 115 (06) 760-767
- 32 Lauvahutanon S, Takahashi H, Shiozawa M. et al. Mechanical properties of composite resin blocks for CAD/CAM. Dent Mater J 2014; 33 (05) 705-710
- 33 Kim KS, Yoon TH, Song KY, Ahn SG. Comparison of mechanical properties in 4 indirect composite resin. J Korean Acad Prosthodont 2007; 45: 21-33
- 34 Revilla-León M, Özcan M. Additive manufacturing technologies used for processing polymers: current status and potential application in prosthetic dentistry. J Prosthodont 2019; 28 (02) 146-158