Open Access
CC BY 4.0 · European Journal of General Dentistry 2023; 12(01): 014-019
DOI: 10.1055/s-0042-1760674
Original Article

In vitro Study of Temperature Changes on the Outer Root Surface of Extracted Human Teeth Under Different Parameters of Intracanal Cryotherapy

1   Department of Operative Dentistry and Endodontics, Faculty of Dental Medicine, Medical University - Plovdiv, Plovdiv, Bulgaria
,
Silviya Dimitrova Dimitrova
1   Department of Operative Dentistry and Endodontics, Faculty of Dental Medicine, Medical University - Plovdiv, Plovdiv, Bulgaria
,
Plamen Ivanov Zagorchev
2   Medical Physics and Biophysics, Medical University-Plovdiv, Plovdiv, Bulgaria
› Institutsangaben

Funding This study was funded by Grant No. 9/2021 of the Medical University-Plovdiv, Plovdiv, Bulgaria.
Preview

Abstract

Objectives The aim of the present study is to investigate the temperature changes on the outer root surface of extracted human teeth during irrigation with different volumes of solutions at different temperatures.

Materials and Methods Thirty premolars extracted for orthodontic or periodontal indications were used for the first experiment and 12 for the second experiment. Root canals were instrumented using WaveOne Gold. Thermosensors were attached to the apical 5 mm and to the middle 5 mm of the outer root surface. Control irrigations with 0.9% NaCl, 2.5% NaOCl, and 17% EDTA at room temperature and experimental irrigations at 2.5°C with 0.9% NaCl, 2.5°C with 2.5% NaOCl, and 2.5°C with 17% EDTA were conducted.

Results During the intracanal cryotherapy, a minimum temperature more than 10°C lower than the initial temperature value was reached. There was no significant difference between the lowest temperature values reached in the irrigations carried out with the three irrigation solutions studied. These results indicate that the effect of intracanal cryotherapy can be successfully achieved using all three types of irrigation solutions, i.e., NaOCl, 0.9% NaCl, EDTA. Intracanal cryotherapy needed to last more than 2 minutes to achieve more than 10°C difference with the initial temperature.

Conclusions A total of 5 mL of irrigation solution for 5 min is insufficient to achieve a cryotherapeutic effect. A temperature difference of 10°C between initial and lowest temperatures recorded was reached fastest at a volume of 20 mL.



Publikationsverlauf

Artikel online veröffentlicht:
06. Juni 2023

© 2023. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/)

Thieme Medical and Scientific Publishers Pvt. Ltd.
A-12, 2nd Floor, Sector 2, Noida-201301 UP, India