Am J Perinatol 2024; 41(10): 1424-1431
DOI: 10.1055/s-0043-1769469
Original Article

Comparing Intubation Rates in the Delivery Room by Interface

1   Department of Pediatrics, OSF Saint Francis Medical Center, University of Illinois College of Medicine at Peoria, Children's Hospital of Illinois, Peoria, Illinois
,
Gretchen L. Kopec
2   Division of Neonatology, OSF Saint Francis Medical Center, University of Illinois College of Medicine at Peoria, Children's Hospital of Illinois, Peoria, Illinois
,
Harveen Kaur
3   University of Illinois College of Medicine at Peoria, Peoria, Illinois
,
Ashley M. Fischer
2   Division of Neonatology, OSF Saint Francis Medical Center, University of Illinois College of Medicine at Peoria, Children's Hospital of Illinois, Peoria, Illinois
› Author Affiliations
Funding None.

Abstract

Objective Positive pressure ventilation (PPV) is crucial to the resuscitation of newborns. Although neonates often require PPV at birth, the optimal interface has not been determined. Both binasal prongs and face masks were deemed acceptable by the International Liaison Committee on Resuscitation in 2010 and have been utilized at our center since 2016; however, the choice is by provider preference. Previous studies have suggested that binasal prongs may be more effective than face masks at avoiding intubation in the delivery room. The objective of this study is to compare intubation rates of binasal prongs versus face masks for delivery room resuscitation of neonates born < 30 weeks' gestation.

Study Design This retrospective study compares delivery room intubation rates by interface for neonates < 30 weeks' gestation born between August 2016 and April 2021 at our level IV neonatal intensive care unit. Exclusion criteria included diagnosis of congenital diaphragmatic hernia, no PPV required, or no resuscitation attempted. Data collected included interface device, demographics, maternal data, delivery room data, admission data, and discharge outcomes. The three interface groups (binasal prongs, face mask, face mask, and binasal prongs) were compared utilizing chi-square, analysis of variance with post hoc analysis, and logistic regression.

Results Mean gestational ages and birth weights for the groups were 27.6 weeks and 1,126 g, 25.7 weeks and 839 g, and 27.1 weeks and 1,028 g, respectively. Neonates resuscitated with face masks were 9.9 times more likely to be intubated in the delivery room and 10.8 times more likely to be intubated at 6 hours of life compared with those resuscitated with binasal prongs after logistic regression analysis.

Conclusion The findings in our study support delivery room resuscitation with binasal prongs as a useful method in reducing the need for intubation both in the delivery room and at 6 hours of life. Further prospective studies are warranted.

Key Points

  • The International Liaison Committee on Resuscitation recommends multiple interface options for neonatal resuscitation.

  • Vermont Oxford Network endorses nasal interface for premature infants.

  • Binasal prongs are associated with lower intubation rates.



Publication History

Received: 20 December 2022

Accepted: 25 April 2023

Article published online:
31 May 2023

© 2023. Thieme. All rights reserved.

Thieme Medical Publishers, Inc.
333 Seventh Avenue, 18th Floor, New York, NY 10001, USA

 
  • References

  • 1 Aziz K, Lee HC, Escobedo MB. et al. Part 5: Neonatal resuscitation: 2020 American heart association guidelines for cardiopulmonary resuscitation and emergency cardiovascular care. Circulation 2020; 142 (16_suppl_2, suppl_2): S524-S550
  • 2 Ersdal HL, Mduma E, Svensen E, Perlman JM. Early initiation of basic resuscitation interventions including face mask ventilation may reduce birth asphyxia related mortality in low-income countries: a prospective descriptive observational study. Resuscitation 2012; 83 (07) 869-873
  • 3 Schmölzer GM, Kumar M, Pichler G, Aziz K, O'Reilly M, Cheung PY. Non-invasive versus invasive respiratory support in preterm infants at birth: systematic review and meta-analysis. BMJ 2013; 347 (03) f5980
  • 4 Perlman JM, Wyllie J, Kattwinkel J. et al; Neonatal Resuscitation Chapter Collaborators. Part 11: Neonatal resuscitation: 2010 international consensus on cardiopulmonary resuscitation and emergency cardiovascular care science with treatment recommendations: 2010 International consensus on cardiopulmonary resuscitation and emergency cardiovascular care science with treatment recommendations. Circulation 2010; 122 (16, suppl 2): S516-S538
  • 5 Schmölzer GM, Dawson JA, Kamlin COF, O'Donnell CPF, Morley CJ, Davis PG. Airway obstruction and gas leak during mask ventilation of preterm infants in the delivery room. Arch Dis Child Fetal Neonatal Ed 2011; 96 (04) F254-F257
  • 6 Gaertner VD, Rüegger CM, O'Currain E. et al. Physiological responses to facemask application in newborns immediately after birth. Arch Dis Child Fetal Neonatal Ed 2021; 106 (04) 381-385
  • 7 Kuypers KLAM, Lamberska T, Martherus T. et al. The effect of a face mask for respiratory support on breathing in preterm infants at birth. Resuscitation 2019; 144: 178-184
  • 8 Biniwale M, Wertheimer F. Decrease in delivery room intubation rates after use of nasal intermittent positive pressure ventilation in the delivery room for resuscitation of very low birth weight infants. Resuscitation 2017; 116: 33-38
  • 9 Capasso L, Capasso A, Raimondi F, Vendemmia M, Araimo G, Paludetto R. A randomized trial comparing oxygen delivery on intermittent positive pressure with nasal cannulae versus facial mask in neonatal primary resuscitation. Acta Paediatr 2005; 94 (02) 197-200
  • 10 Parker A, Greenough A. Resuscitation at birth. In: Neonatal Respiratory Disorders. 2nd Ed.. London, United Kingdom: CRC Press; 2003: 151-166
  • 11 Portal. Vtoxford.org. Accessed March 8, 2023 at: https://portal.vtoxford.org/qiProgramPage?id=11586&subPage=Minimizing%20Lung%20Injury
  • 12 Machumpurath S, O'Currain E, Dawson JA, Davis PG. Interfaces for non-invasive neonatal resuscitation in the delivery room: a systematic review and meta-analysis. Resuscitation 2020; 156: 244-250
  • 13 Donaldsson S, Drevhammar T, Li Y. et al; CORSAD Trial Investigators. Comparison of respiratory support after delivery in infants born before 28 weeks' gestational age: the CORSAD randomized clinical trial: the CORSAD randomized clinical trial. JAMA Pediatr 2021; 175 (09) 911-918
  • 14 Committee on Fetus and Newborn, American Academy of Pediatrics. Respiratory support in preterm infants at birth. Pediatrics 2014; 133 (01) 171-174
  • 15 Verder H, Albertsen P, Ebbesen F. et al. Nasal continuous positive airway pressure and early surfactant therapy for respiratory distress syndrome in newborns of less than 30 weeks' gestation. Pediatrics 1999; 103 (02) E24
  • 16 Finer NN, Carlo WA, Walsh MC. et al; SUPPORT Study Group of the Eunice Kennedy Shriver NICHD Neonatal Research Network. Early CPAP versus surfactant in extremely preterm infants. N Engl J Med 2010; 362 (21) 1970-1979
  • 17 Morley CJ, Davis PG, Doyle LW, Brion LP, Hascoet JM, Carlin JB. COIN Trial Investigators. Nasal CPAP or intubation at birth for very preterm infants. N Engl J Med 2008; 358 (07) 700-708
  • 18 Herting E, Härtel C, Göpel W. Less invasive surfactant administration (LISA): chances and limitations. Arch Dis Child Fetal Neonatal Ed 2019; 104 (06) F655-F659
  • 19 Hodgson KA, Owen LS, Kamlin COF. et al. Nasal high-flow therapy during neonatal endotracheal intubation. N Engl J Med 2022; 386 (17) 1627-1637