Subscribe to RSS
DOI: 10.1055/s-0043-1774338
Effect of Number of Sutures on Microvascular Venous Anastomosis in Experimental Rats
Summary
In this experimental study better patency rates (80 percent) were achieved when 8 to 9 sutures were used for anastomosis. Accurate edge to edge approximation and minimal medial damage were found to be prime factors in the success of venous anastomosis. Use of less number of sutures (4-6) resulted in significant leakage and early occlusion of the veins.
Publication History
Article published online:
23 August 2023
© 2023. Association of Plastic Surgeons of India. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/)
Thieme Medical and Scientific Publishers Pvt. Ltd.
A-12, 2nd Floor, Sector 2, Noida-201301 UP, India