CC BY-NC-ND 4.0 · Indian J Plast Surg 2024; 57(05): 394-400
DOI: 10.1055/s-0044-1787565
Original Article

End-to-Side Venous Anastomosis with IJV: Improving Outcomes of Microvascular Anastomosis in Head and Neck Reconstruction

Anupam Golash
1   Department of Plastic Surgery, Calcutta Medical Research Institute, Kolkata, West Bengal, India
,
2   Department of Plastic Surgery, Institute of Medical Sciences, Banaras Hindu University, Varanasi, Uttar Pradesh, India
,
Aditya V. Kanoi
3   Department of Reconstructive Surgery, Narayana Superspeciality Hospital, Howrah, West Bengal, India
,
Swaraj Hanspal
1   Department of Plastic Surgery, Calcutta Medical Research Institute, Kolkata, West Bengal, India
,
Abhijit Golash
4   Department of General Surgery, Calcutta Medical College, Kolkata, West Bengal, India
› Author Affiliations
Funding None.

Abstract

Background End-to-side (ES) venous anastomosis is an established approach for head and neck reconstruction and has several benefits over conventional end-to-end (EE) anastomosis. However, this is not preferred by all, which may be due to technical preferences for an EE anastomosis by many surgeons. We present here our experience of routine ES venous anastomosis for head and neck reconstruction over the past 8 years.

Materials and Methods All consecutive head and neck malignancy patients reconstructed with free flap and our routine ES internal jugular vein (IJV) anastomosis approach between 2015 and 2023 have been included in this study. Flap-related variables are reviewed retrospectively.

Results Reconstruction was done with a total of 585 free flaps including 303 radial forearm flaps (RFFs), 143 osteocutaneous fibula flaps (OCFFs), and 139 anterolateral thigh (ALT) flaps. The flap survival rate was 573/585 (97.95%). Re-exploration and salvage rates were 45/585 (7.69%) and 38/45, respectively (84.44%).

Conclusion Routine use of ES anastomosis simplifies microvascular anastomosis by avoiding efforts related to the selection of recipient vessels, providing a single large-caliber venous outlet, the favorable geometric orientation of the pedicle, and ease of re-exploration. The vascular anastomosis for RFF, ALT, and OCFF flap is feasible with 7–0 sutures and under 4.5X loupe magnification with this approach quite conveniently with similar outcomes to the reported flap survival rate in the contemporary practice.



Publication History

Article published online:
11 June 2024

© 2024. Association of Plastic Surgeons of India. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/)

Thieme Medical and Scientific Publishers Pvt. Ltd.
A-12, 2nd Floor, Sector 2, Noida-201301 UP, India

 
  • References

  • 1 Bui DT, Cordeiro PG, Hu QY, Disa JJ, Pusic A, Mehrara BJ. Free flap reexploration: indications, treatment, and outcomes in 1193 free flaps. Plast Reconstr Surg 2007; 119 (07) 2092-2100
  • 2 Yamamoto Y, Nohira K, Kuwahara H, Sekido M, Furukawa H, Sugihara T. Superiority of end-to-side anastomosis with the internal jugular vein: the experience of 80 cases in head and neck microsurgical reconstruction. Br J Plast Surg 1999; 52 (02) 88-91
  • 3 Halvorson EG, Cordeiro PG. Go for the jugular: a 10-year experience with end-to-side anastomosis to the internal jugular vein in 320 head and neck free flaps. Ann Plast Surg 2007; 59 (01) 31-35 , discussion 35
  • 4 Ross GL, Ang ES, Golger A. et al. Which venous system to choose for anastomosis in head and neck reconstructions?. Ann Plast Surg 2008; 61 (04) 396-398
  • 5 Golash A, Bera S, Bhaviya BS, Kanoi AV, Pai AA, Golash A. Clinical utility of the communicating vein in free radial artery forearm flaps: best of both worlds. J Plast Reconstr Aesthet Surg 2019; 72 (07) 1219-1243
  • 6 Piazza C, Taglietti V, Paderno A, Nicolai P. End-to-end versus end-to-side venous microanastomoses in head and neck reconstruction. Eur Arch Otorhinolaryngol 2014; 271 (01) 157-162
  • 7 Ueda K, Harii K, Nakatsuka T, Asato H, Yamada A. Comparison of end-to-end and end-to-side venous anastomosis in free-tissue transfer following resection of head and neck tumors. Microsurgery 1996; 17 (03) 146-149
  • 8 Verhelle NA, Heymans O. How to deal with difficult microsurgical end-to-side anastomoses. Microsurgery 2005; 25 (03) 203-208
  • 9 Graham BB, Varvares MA. End-to-side venous anastomosis with the internal jugular vein stump: a preliminary report. Head Neck 2004; 26 (06) 537-540
  • 10 Yin SC, Su XZ, So HI. et al. Comparison of internal jugular vein system anastomosis and external jugular vein system anastomosis in free flaps for head and neck reconstruction: a meta-analysis. J Oral Maxillofac Surg 2020; 78 (01) 142-152
  • 11 Chalian AA, Anderson TD, Weinstein GS, Weber RS. Internal jugular vein versus external jugular vein anastamosis: implications for successful free tissue transfer. Head Neck 2001; 23 (06) 475-478
  • 12 Tahara S, Takagi T, Kinishi M, Makino K, Amatsu M. Role of the perforating vein in vascular pedicle of free forearm flap. Microsurgery 1995; 16 (11) 743-745
  • 13 Ichinose A, Tahara S, Terashi H. et al. Importance of the deep vein in the drainage of a radial forearm flap: a haemodynamic study. Scand J Plast Reconstr Surg Hand Surg 2003; 37 (03) 145-149
  • 14 Sen C, Agir H, Iscen D. Simple and reliable procedure for end-to-side microvascular anastomosis: the diamond technique. Microsurgery 2006; 26 (03) 160-164
  • 15 Ross DA, Ariyan S, Restifo R, Sasaki CT. Use of the operating microscope and loupes for head and neck free microvascular tissue transfer: a retrospective comparison. Arch Otolaryngol Head Neck Surg 2003; 129 (02) 189-193
  • 16 Pieptu D, Luchian S. Loupes-only microsurgery. Microsurgery 2003; 23 (03) 181-188
  • 17 Chiu YH, Chang DH, Perng CK. Vascular complications and free flap salvage in head and neck reconstructive surgery: analysis of 150 cases of reexploration. Ann Plast Surg 2017; 78 (3, suppl 2): S83-S88