Subscribe to RSS
DOI: 10.1055/s-0044-1788705
Over-the-Scope Clip Application for Duodenal Ulcer: Easier Said than Done
Funding None.A 35-year-old man presented with hematemesis and syncope for 1 day. He was hospitalized and immediately resuscitated with intravenous fluids. His investigation revealed hemoglobin of 5 g/dL and normal liver and renal function tests. After resuscitation with packed cell transfusion, gastroscopy was performed under conscious sedation, which revealed an ulcer (1 cm in size) (Forrest class IIA) with visible vessel on the anterior wall of duodenal bulb. Various options like injection (adrenaline), thermal coagulative therapy, and through-the-scope clips were considered; however, due to large ulcer size and fibrotic base, over-the-scope clip (OTSC; 12/6T, Ovesco Endoscopy AG, Tubingen, Germany) application was planned. Risk of rebleeding and failure of therapy were explained. OTSC clip was mounted on tip of gastroscope (GIF Q150, Olympus, Tokyo, Japan) and whole assembly was then passed across the postcricoid region with mild resistance ([Video 1]). In stomach, while attempting to cross pylorus, Ovesco applicator cap with mounted clip got stuck at pylorus and detached from the scope; hence, the scope was withdrawn carefully after loosening thread from hand wheel. Gastroscope was passed again to retrieve the clip. Ovesco applicator cap with clip was grasped with rat tooth forceps and gradually pulled; however, on withdrawing from the postcricoid region, clip got dislodged and mal-deployed in the upper esophageal region accidentally. So, the scope was reinserted and the mal-deployed clip was removed with rat tooth forceps with sustained pressure. After removal, superficial submucosal injury was noted at the clip site. Pylorus was dilated using circumferential radial expansion balloon (CRE, Boston Scientific, Marlborough, Massachusetts, United States) up to 15 mm. Another OTSC (12/6T) was mounted on the gastroscope (GIF -1TQ160, Olympus, Tokyo, Japan) and scope was passed in duodenal bulb. With mild suction clip was applied over the ulcer site, and after application, complete grasping of ulcer within the clip was confirmed ([Fig. 1A–F]). As the patient had upper esophageal submucosal injury, nasogastric (NG) tube was placed. Proton pump inhibitor infusion was continued and gradually patient was started on NG feeding. There was no further drop in hemoglobin, and the patient was discharged after 72 hours of observation after removal of NG tube. OTSC is safe and effective modality as primary as well as rescue strategy for the peptic ulcer bleeding.[1] [2] [3] This video demonstrates the problems encountered during OTSC application and their troubleshooting.
Video 1 Video demonstrating troubleshooting during OTSC application for duodenal ulcer bleeding. OTSC, over-the-scope clip.
Quality:
Publication History
Article published online:
16 September 2024
© 2024. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/)
Thieme Medical and Scientific Publishers Pvt. Ltd.
A-12, 2nd Floor, Sector 2, Noida-201301 UP, India
-
References
- 1 Schmidt A, Gölder S, Goetz M. et al. Over-the-scope clips are more effective than standard endoscopic therapy for patients with recurrent bleeding of peptic ulcers. Gastroenterology 2018; 155 (03) 674-686.e6
- 2 Chavan R, Nabi Z, Karayampudi A. et al. Outcomes of over-the-scope clip application in various gastrointestinal indications: experience from a tertiary care in India. Ann Gastroenterol 2020; 33 (05) 473-479
- 3 Meier B, Wannhoff A, Denzer U. et al. Over-the-scope-clips versus standard treatment in high-risk patients with acute non-variceal upper gastrointestinal bleeding: a randomised controlled trial (STING-2). Gut 2022; 71 (07) 1251-1258