CC BY 4.0 · European Journal of General Dentistry
DOI: 10.1055/s-0044-1791844
Review Article

Assessing the Current Landscape and Future Directions of Digital Denture Technology

Ravinder S. Saini
1   Department of Dental Technology, COAMS, King Khalid University, Abha, Saudi Arabia
,
2   Department of Clinical Sciences, College of Dentistry, Ajman, United Arab Emirates
3   Centre of Medical and Bio-allied Health Sciences Research, Ajman University, Ajman, United Arab Emirates
4   School of Dentistry, University of Jordan, Amman, Jordan
5   Department of Dental Materials, Islamic International Dental College, Riphah International University, Islamabad, Pakistan
,
6   Department of Restorative Dentistry, College of Dentistry, King Faisal University, Al Ahsa, Saudi Arabia
,
7   Biomedical Science, Faculty of Chemical-Biological Sciences, Autonomous University of Guerrero, Guerrero, Mexico
,
8   Department of Research Analytics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, India
9   Department of Prosthodontics, Faculty of Stomatology, Yerevan State Medical University after Mkhitar Heratsi, Yerevan, Armenia
› Author Affiliations
Funding The authors extend their appreciation to the Deanship of Research and Graduate Studies at King Khalid University for funding this work through Review Article Project under grant number RA.KKU/7/45.

Abstract

Digital dentures are removable dental prostheses fabricated using computer-aided design/computer-aided manufacturing (CAD/CAM) technology. This study aimed to explore the trends in digital dentures. A comprehensive four-phase search and selection strategy was framed.

Dimensions and Lens.org databases were used. Boolean operators were used to combine keywords.

The most significant growth occurred by 2021, with 71 publications and 984 citations. Egypt had the highest publication rankings, with 46 total publications (TP) and 45 total citations (TC). The University of Geneva played a significant role in contributing to 16 TP and 491 TC. Egyptian Dental Journal ranked at the top. The group with four authors had an even higher number of authorships, with a total of 60. The top four keywords were CAD/CAM, 3D printing, CAD-CAM, complete denture, and digital dentistry. The Glossary of Prosthodontic Terms, Ninth Edition, was referenced 614 times and had the highest average number of citations (75.2). The top three writers had strong relationships with the three sources and preferred to publish using four keywords. The 11-author group, cluster 6, had the highest level of network cooperation.

In conclusion, research on digital dentures has grown in terms of number of articles and citations.

Authors' Contributions

M.S.Z. and N.A. developed the concept and methodology. R.S.S. was responsible for data curation and formal analysis. R.S.S. and M.A.A-S. were responsible for investigation and resources. Original draft preparation was done by R.S.S., A.H., and M.A.A-S. Writing, reviewing, and editing were done by M.S.Z. and N.A. Supervision and project administration were done by R.S.S. and A.H. The guarantor of the study was R.S.S.


Data Availability Statement

The data are available upon genuine request from the corresponding author.




Publication History

Article published online:
29 November 2024

© 2024. The Author(s). This is an open access article published by Thieme under the terms of the Creative Commons Attribution License, permitting unrestricted use, distribution, and reproduction so long as the original work is properly cited. (https://creativecommons.org/licenses/by/4.0/)

Thieme Medical and Scientific Publishers Pvt. Ltd.
A-12, 2nd Floor, Sector 2, Noida-201301 UP, India

 
  • References

  • 1 Abualsaud R, Gad MM. Flexural strength of CAD/CAM denture base materials: systematic review and meta-analysis of in-vitro studies. J Int Soc Prev Community Dent 2022; 12 (02) 160-170
  • 2 Anadioti E, Musharbash L, Blatz MB, Papavasiliou G, Kamposiora P. 3D printed complete removable dental prostheses: a narrative review. BMC Oral Health 2020; 20 (01) 343
  • 3 Alhallak K, Hagi-Pavli E, Nankali A. A review on clinical use of CAD/CAM and 3D printed dentures. Br Dent J 2023; 2023: 1-5
  • 4 Villias A, Karkazis H, Yannikakis S, Theocharopoulos A, Sykaras N, Polyzois G. Current status of digital complete dentures technology. Prosthesis 2021; 3 (03) 229-244
  • 5 Goodacre CJ, Goodacre BJ, Baba NZ. Should digital complete dentures be part of a contemporary prosthodontic education?. J Prosthodont 2021; 30 (S2): 163-169
  • 6 Ubale D, Uddanwadiker RV. Latest trends in digital dentistry: a review. IJSRSET 2018; 4 (8) 533-539
  • 7 Sadowsky SJ. Complete-denture aesthetics revisited in the digital age. J Calif Dent Assoc 2023; 49: 393-399
  • 8 Alhajj MN, Al-Sanabani FA, Alkheraif AA, Smran A, Alqerban A, Samran A. Bibliometric analysis and evaluation of The Journal of Prosthetic Dentistry from 1970 to 2019. J Prosthet Dent 2023; 129 (02) 323-340
  • 9 Khan AS, Ur Rehman S, AlMaimouni YK, Ahmad S, Khan M, Ashiq M. Bibliometric analysis of literature published on antibacterial dental adhesive from 1996-2020. Polymers (Basel) 2020; 12 (12) 1-29
  • 10 Jayaratne YSN, Zwahlen RA. The evolution of dental journals from 2003 to 2012: a bibliometric analysis. PLoS One 2015; 10 (03) e0119503
  • 11 Liu S, Chen J, Wang J. et al. Current research status and frontiers of Artificial Intelligence in Stomatology: A Bibliometric Analysis (2010-2022). Research Square 2023;
  • 12 Cagna DR, Donovan TE, McKee JR. et al. Annual review of selected scientific literature: a report of the Committee on Scientific Investigation of the American Academy of Restorative Dentistry. J Prosthet Dent 2021; 126 (03) 276-359
  • 13 Adnan S, Zafar K, Khan FR, Ullah R. Bibliometric study on the literature related to dental research and education published in Journal of Pakistan Medical Association. J Pak Med Assoc 2022; 72 (01) 84-92
  • 14 Ohara K, Isshiki Y, Hoshi N. et al. Patient satisfaction with conventional dentures vs. digital dentures fabricated using 3D-printing: a randomized crossover trial. J Prosthodont Res 2022; 66 (04) 623-629
  • 15 Srinivasan M, Kamnoedboon P, McKenna G. et al. CAD-CAM removable complete dentures: a systematic review and meta-analysis of trueness of fit, biocompatibility, mechanical properties, surface characteristics, color stability, time-cost analysis, clinical and patient-reported outcomes. J Dent 2021; 113: 103777
  • 16 Srinivasan M, Kalberer N, Fankhauser N, Naharro M, Maniewicz S, Müller F. CAD-CAM complete removable dental prostheses: a double-blind, randomized, crossover clinical trial evaluating milled and 3D-printed dentures. J Dent 2021; 115: 103842
  • 17 Arakawa I, Al-Haj Husain N, Srinivasan M, Maniewicz S, Abou-Ayash S, Schimmel M. Clinical outcomes and costs of conventional and digital complete dentures in a university clinic: a retrospective study. J Prosthet Dent 2022; 128 (03) 390-395
  • 18 Takaichi A, Fueki K, Murakami N. et al. A systematic review of digital removable partial dentures. Part II: CAD/CAM framework, artificial teeth, and denture base. J Prosthodont Res 2022; 66 (01) 53-67
  • 19 Chhabra M, Nanditha Kumar M, RaghavendraSwamy KN, Thippeswamy HM. Flexural strength and impact strength of heat-cured acrylic and 3D printed denture base resins: a comparative in vitro study. J Oral Biol Craniofac Res 2022; 12 (01) 1-3
  • 20 Wada M, Mameno T, Tsujioka Y, Yamashita M, Ikebe K. Effective utilization of digital technology in complete denture fabrication. J Oral Sci 2022; 64 (02) 172-174
  • 21 El-Shaheed NH, Lamfon HA, Salama RI, Faramawy AMG, Mostafa AZH. Tissue surface adaptation and clinical performance of CAD-CAM milled versus conventional implant-assisted mandibular overdenture. Int J Dent 2022; 2022: 8220233
  • 22 Prpić V, Schauperl Z, Glavina D, Ćatić A, Čimić S. Comparison of shear bond strengths of different types of denture teeth to different denture base resins. J Adv Prosthodont 2020; 12 (06) 376-382
  • 23 Taghva M, Enteghad S, Jamali A, Mohaghegh M. Comparison of shear bond strength of CAD/CAM and conventional heat-polymerized acrylic resin denture bases to auto-polymerized and heat-polymerized acrylic resins after aging. J Clin Exp Dent 2022; 14 (01) e72-e78
  • 24 Janeva NM, Kovacevska G, Elencevski S, Panchevska S, Mijoska A, Lazarevska B. Advantages of CAD/CAM versus conventional complete dentures: a review. Open Access Maced J Med Sci 2018; 6 (08) 1498-1502
  • 25 Charoenphol K, Peampring C. Fit accuracy of complete denture base fabricated by CAD/CAM milling and 3D-printing methods. Eur J Dent 2023; 17 (03) 889-894
  • 26 Srinivasan M, Chien EC, Kalberer N. et al. Analysis of the residual monomer content in milled and 3D-printed removable CAD-CAM complete dentures: an in vitro study. J Dent 2022; 120: 104094
  • 27 Alzaid M, AlToraibily F, Al-Qarni FD. et al. The effect of salivary pH on the flexural strength and surface properties of CAD/CAM Denture Base Materials. Eur J Dent 2023; 17 (01) 234-241
  • 28 Ishida Y, Kuwajima Y, Kobayashi T. et al. Current implementation of digital dentistry for removable prosthodontics in US dental schools. Int J Dent 2022; 2022: 7331185
  • 29 Zeidan AAE, Abd Elrahim RA, Abd El Hakim AF, Harby NM, Helal MA. Evaluation of surface properties and elastic modulus of CAD-CAM milled, 3D printed, and compression moulded denture base resins: an in vitro study. J Int Soc Prev Community Dent 2022; 12 (06) 630-637
  • 30 Gad MM, Alshehri SZ, Alhamid SA. et al. Water sorption, solubility, and translucency of 3D-printed denture base resins. Dent J 2022; 10 (03) 42
  • 31 Wang YJ, Chu TG, Lin WS. Translucency parameter and color masking ability of CAD-CAM denture base materials against metal substrates. J Prosthodont 2023; 32 (S1): 61-67
  • 32 Emera RMK, Shady M, Alnajih MA. Comparison of retention and denture base adaptation between conventional and 3D-printed complete dentures. J Dent Res Dent Clin Dent Prospect 2022; 16 (03) 179-185
  • 33 Steinmassl O, Dumfahrt H, Grunert I, Steinmassl PA. CAD/CAM produces dentures with improved fit. Clin Oral Investig 2018; 22 (08) 2829-2835
  • 34 Jurado C, Sayed M, Fu C-C, Villalobos-Tinoco J, Tsujimoto A. Computer-aided design and computer-aided manufacturing (CAD/CAM) complete dentures for atrophic alveolar ridges: workflow combining conventional and novel techniques. Cureus 2022; 14 (01) e21093
  • 35 Deng K, Chen H, Wang Y, Zhou Y, Sun Y. Evaluation of functional suitable digital complete denture system based on 3D printing technology. J Adv Prosthodont 2021; 13 (06) 361-372
  • 36 Steinmassl PA, Wiedemair V, Huck C. et al. Do CAD/CAM dentures really release less monomer than conventional dentures?. Clin Oral Investig 2017; 21 (05) 1697-1705
  • 37 Steinmassl O, Dumfahrt H, Grunert I, Steinmassl PA. Influence of CAD/CAM fabrication on denture surface properties. J Oral Rehabil 2018; 45 (05) 406-413
  • 38 Park SJ, Lee JS. Effect of surface treatment on shear bond strength of relining material and 3D-printed denture base. J Adv Prosthodont 2022; 14 (04) 262-272
  • 39 Janeva N, Kovacevska G, Janev E. Complete dentures fabricated with CAD/CAM technology and a traditional clinical recording method. Open Access Maced J Med Sci 2017; 5 (06) 785-789
  • 40 Alfouzan AF, Alotiabi HM, Labban N, Al-Otaibi HN, Al Taweel SM, AlShehri HA. Color stability of 3D-printed denture resins: effect of aging, mechanical brushing and immersion in staining medium. J Adv Prosthodont 2021; 13 (03) 160-171
  • 41 John AV, Abraham G, Alias A. Two-visit CAD/CAM milled dentures in the rehabilitation of edentulous arches: a case series. J Indian Prosthodont Soc 2019; 19 (01) 88-92
  • 42 Lourinho C, Salgado H, Correia A, Fonseca P. Mechanical properties of polymethyl methacrylate as denture base material: heat-polymerized vs. 3D-printed-systematic review and meta-analysis of in vitro studies. Biomedicines 2022; 10 (10) 2565
  • 43 Srinivasan M, Schimmel M, Leles C, McKenna G. Managing edentate older adults. Prim Dent J 2020; 9 (03) 29-33
  • 44 Kalberer N, Mehl A, Schimmel M, Müller F, Srinivasan M. CAD-CAM milled versus rapidly prototyped (3D-printed) complete dentures: an in vitro evaluation of trueness. J Prosthet Dent 2019; 121 (04) 637-643
  • 45 Bajunaid SO. A first experience with digital complete overdentures. Saudi Dent J 2016; 28 (03) 148-153
  • 46 Al-Fouzan AF, Al-Mejrad LA, Albarrag AM. Adherence of Candida to complete denture surfaces in vitro: a comparison of conventional and CAD/CAM complete dentures. J Adv Prosthodont 2017; 9 (05) 402-408
  • 47 Srinivasan M, Kalberer N, Naharro M, Marchand L, Lee H, Müller F. CAD-CAM milled dentures: the Geneva protocols for digital dentures. J Prosthet Dent 2020; 123 (01) 27-37
  • 48 Srinivasan M, Kalberer N, Kamnoedboon P. et al. CAD-CAM complete denture resins: an evaluation of biocompatibility, mechanical properties, and surface characteristics. J Dent 2021; 114: 103785
  • 49 Della Bona A, Cantelli V, Britto VT, Collares KF, Stansbury JW. 3D printing restorative materials using a stereolithographic technique: a systematic review. Dent Mater 2021; 37 (02) 336-350
  • 50 Alammari MR. The influence of polishing techniques on pre-polymerized CADacrylic resin denture bases. Electron Physician 2017; 9 (10) 5452-5458
  • 51 Han SY, Moon YH, Lee J. Shear bond strength between CAD/CAM denture base resin and denture artificial teeth when bonded with resin cement. J Adv Prosthodont 2020; 12 (05) 251-258
  • 52 Soeda Y, Kanazawa M, Arakida T, Iwaki M, Minakuchi S. CAD-CAM milled complete dentures with custom disks and prefabricated artificial teeth: a dental technique. J Prosthet Dent 2022; 127 (01) 55-58
  • 53 Mendonça G, Edwards SP, Mayers CA, Meneghetti PC, Liu F. Digital immediate complete denture for a patient with rhabdomyosarcoma: a clinical report. J Prosthodont 2021; 30 (03) 196-201
  • 54 Roser CJ, Rückschloß T, Zenthöfer A, Rammelsberg P, Lux CJ, Rues S. Orthodontic shear bond strength and ultimate load tests of CAD/CAM produced artificial teeth. Clin Oral Investig 2022; 26 (12) 7149-7155
  • 55 Chang YH, Lee CY, Hsu MS, Du JK, Chen KK, Wu JH. Effect of toothbrush/dentifrice abrasion on weight variation, surface roughness, surface morphology and hardness of conventional and CAD/CAM denture base materials. Dent Mater J 2021; 40 (01) 220-227
  • 56 Larijani M, Zareshahrabadi Z, Alhavaz A. et al. Evaluation of Candida albicans biofilm formation on conventional and computer-aided-design/computer-aided manufacturing (CAD/CAM) denture base materials. Curr Med Mycol 2022; 8 (03) 23-29
  • 57 Iwaki M, Kanazawa M, Arakida T, Minakuchi S. Mechanical properties of a polymethyl methacrylate block for CAD/CAM dentures. J Oral Sci 2020; 62 (04) 420-422
  • 58 de Mendonça AF, Furtado de Mendonça M, White GS, Sara G, Littlefair D. Total CAD/CAM supported method for manufacturing removable complete dentures. Case Rep Dent 2016; 2016: 1259581
  • 59 Unkovskiy A, Schmidt F, Beuer F, Li P, Spintzyk S, Kraemer Fernandez P. Stereolithography vs. direct light processing for rapid manufacturing of complete denture bases: an in vitro accuracy analysis. J Clin Med 2021; 10 (05) 1-14
  • 60 Venezia P, Torsello F, Santomauro V, Dibello V, Cavalcanti R. Full digital workflow for the treatment of an edentulous patient with guided surgery, immediate loading and 3D-printed hybrid prosthesis: the BARI technique 2.0. A case report. Int J Environ Res Public Health 2019; 16 (24) 5160
  • 61 Millet C, Virard F, Dougnac-Galant T, Ducret M. CAD-CAM immediate to definitive complete denture transition: a digital dental technique. J Prosthet Dent 2020; 124 (06) 642-646
  • 62 Perea-Lowery L, Minja IK, Lassila L, Ramakrishnaiah R, Vallittu PK. Assessment of CAD-CAM polymers for digitally fabricated complete dentures. J Prosthet Dent 2021; 125 (01) 175-181
  • 63 Bürgers R, Schubert A, Müller J. et al. Cytotoxicity of 3D-printed, milled, and conventional oral splint resins to L929 cells and human gingival fibroblasts. Clin Exp Dent Res 2022; 8 (03) 650-657
  • 64 Altarazi A, Haider J, Alhotan A, Silikas N, Devlin H. Assessing the physical and mechanical properties of 3D printed acrylic material for denture base application. Dent Mater 2022; 38 (12) 1841-1854
  • 65 Alageel O, Alsadon O, Almansour H, Alshehri A, Alhabbad F, Alsarani M. Assessment of effect of accelerated aging on interim fixed dental materials using digital technologies. J Adv Prosthodont 2022; 14 (06) 360-368
  • 66 Abd El Galil EG, Mohamed SL, Rizk FN, Sabet ME. Evaluation of two computer-aided design software on the adaptation of digitally constructed maxillary complete denture. J Indian Prosthodont Soc 2021; 21 (04) 383-390
  • 67 Srinivasan M, Schimmel M, Naharro M, O' Neill C, McKenna G, Müller F. CAD/CAM milled removable complete dentures: time and cost estimation study. J Dent 2019; 80: 75-79
  • 68 El Aziz MSA, El Megid Tella EAESA. Fully digital workflow for reinforced mandibular implant overdenture: a novel method. J Indian Prosthodont Soc 2022; 22 (02) 205-209
  • 69 Ayman A-D. The residual monomer content and mechanical properties of CADresins used in the fabrication of complete dentures as compared to heat cured resins. Electron Physician 2017; 9 (07) 4766-4772
  • 70 Khorsandi D, Fahimipour A, Abasian P. et al. 3D and 4D printing in dentistry and maxillofacial surgery: printing techniques, materials, and applications. Acta Biomater 2021; 122: 26-49
  • 71 Atalay S, Çakmak G, Fonseca M, Schimmel M, Yilmaz B. Effect of different disinfection protocols on the surface properties of CAD-CAM denture base materials. J Prosthet Dent 2023; 130 (05) 787-795
  • 72 Hickl V, Strasser T, Schmid A, Rosentritt M. Effects of storage and toothbrush simulation on color, gloss, and roughness of CAD/CAM, hand-cast, thermoforming, and 3D-printed splint materials. Clin Oral Investig 2022; 26 (05) 4183-4194
  • 73 Cristache CM, Totu EE, Iorgulescu G. et al. Eighteen months follow-up with patient-centered outcomes assessment of complete dentures manufactured using a hybrid nanocomposite and additive CAD/CAM protocol. J Clin Med 2020; 9 (02) 324
  • 74 Charoenphol K, Peampring C. An in vitro study of intaglio surface, periphery/palatal seal area, and primary bearing area adaptation of 3D-printed denture base manufactured in various build angles. Int J Dent 2022; 2022: 3824894
  • 75 Krishnamurthy DM, Singh R, Mistry G. Interim three-dimensional printed overlay prosthesis for an adolescent patient with oligodontia. J Indian Prosthodont Soc 2021; 21 (03) 304-307
  • 76 Jo YH, Lee WJ, Lee JH, Yoon HI. Antifungal activity, mechanical properties, and accuracy of three-dimensionally printed denture base with microencapsulated phytochemicals on varying post-polymerization time. BMC Oral Health 2022; 22 (01) 611
  • 77 Viotto HEDC, Silva MDD, Nunes TSBS, Coelho SRG, Pero AC. Effect of repair methods and materials on the flexural strength of 3D-printed denture base resin. J Adv Prosthodont 2022; 14 (05) 305-314
  • 78 Jeon S, Jo YH, Yoon HI, Han JS. Effect of phytochemical-filled microcapsules with antifungal activity on material properties and dimensional accuracy of denture base resin for three-dimensional printing. BMC Oral Health 2022; 22 (01) 178
  • 79 Lee S, Hong SJ, Paek J, Pae A, Kwon KR, Noh K. Comparing accuracy of denture bases fabricated by injection molding, CAD/CAM milling, and rapid prototyping method. J Adv Prosthodont 2019; 11 (01) 55-64
  • 80 Srinivasan M, Gjengedal H, Cattani-Lorente M. et al. CAD/CAM milled complete removable dental prostheses: an in vitro evaluation of biocompatibility, mechanical properties, and surface roughness. Dent Mater J 2018; 37 (04) 526-533
  • 81 Chebib N, Imamura Y, El Osta N, Srinivasan M, Müller F, Maniewicz S. Fit and retention of complete denture bases: part II—conventional impressions versus digital scans: a clinical controlled crossover study. J Prosthet Dent 2024; 131 (04) 618-625
  • 82 Awad AN, Cho SH, Kesterke MJ, Chen JH. Comparison of tensile bond strength of denture reline materials on denture bases fabricated with CAD-CAM technology. J Prosthet Dent 2023; 129 (04) 616-622
  • 83 Spintzyk S, Schmunk R, Kraemer Fernandez P, Huettig F, Unkovskiy A. 3D printing of polyamide to fabricate a non-metal clasp removable partial denture via fused filament fabrication: a case report. Int J Environ Res Public Health 2021; 18 (16) 8241
  • 84 Tasaka A, Uekubo Y, Mitsui T. et al. Applying intraoral scanner to residual ridge in edentulous regions: in vitro evaluation of inter-operator validity to confirm trueness. BMC Oral Health 2019; 19 (01) 264
  • 85 Kontis P, Güth JF, Schubert O, Keul C. Accuracy of intraoral scans of edentulous jaws with different generations of intraoral scanners compared to laboratory scans. J Adv Prosthodont 2021; 13 (05) 316-326
  • 86 Yoshidome K, Torii M, Kawamura N, Shimpo H, Ohkubo C. Trueness and fitting accuracy of maxillary 3D printed complete dentures. J Prosthodont Res 2021; 65 (04) 559-564
  • 87 Dayan C, Guven MC, Gencel B, Bural C. A comparison of the color stability of conventional and CAD/CAM polymethyl methacrylate denture base materials. Acta Stomatol Croat 2019; 53 (02) 158-167
  • 88 Ahmed N, Abbasi MS, Haider S. et al. Fit accuracy of removable partial denture frameworks fabricated with CAD/CAM, rapid prototyping, and conventional techniques: a systematic review. BioMed Res Int 2021; 2021: 3194433
  • 89 Srinivasan M, Cantin Y, Mehl A, Gjengedal H, Müller F, Schimmel M. CAD/CAM milled removable complete dentures: an in vitro evaluation of trueness. Clin Oral Investig 2017; 21 (06) 2007-2019
  • 90 Tasaka A, Okano H, Odaka K. et al. Comparison of artificial tooth position in dentures fabricated by heat curing and additive manufacturing. Aust Dent J 2021; 66 (02) 182-187
  • 91 Watarai Y, Koide K, Ota S, Mizuhashi F. Examination of facial measurement on the image using a noncontact three-dimensional measurement device. J Family Med Prim Care 2022; 11 (12) 7776-7782
  • 92 Hao J, Murakami N, Yamazaki T. et al. Flexural and fatigue properties of polyester disk material for milled resin clasps. Dent Mater J 2021; 40 (06) 1359-1364
  • 93 Alfallaj HA, Afrashtehfar KI, Asiri AK, Almasoud FS, Alnaqa GH, Al-Angari NS. The status of digital dental technology implementation in the Saudi dental schools' curriculum: a national cross-sectional survey for healthcare digitization. Int J Environ Res Public Health 2022; 20 (01) 321
  • 94 Keshtgar S, Tosson F, Mavani D, Sadhia Hussain R, Movahedi S, Austin R. Service evaluation of recording jaw registrations for removable partial dentures in NHS general dental practices. Prim Dent J 2020; 9 (01) 49-55
  • 95 Çelakıl T, Demir A, Keskin H. Sectional mandibular complete denture for a total maxillectomy patient with trismus: a clinical report. J Istanb Univ Fac Dent 2017; 51 (03) 38-44
  • 96 Katheng A, Kanazawa M, Komagamine Y, Iwaki M, Namano S, Minakuchi S. Effect of post-rinsing time and method on accuracy of denture base manufactured with stereolithography. J Adv Prosthodont 2022; 14 (01) 45-55
  • 97 Kihara H, Sugawara S, Yokota J. et al. Applications of three-dimensional printers in prosthetic dentistry. J Oral Sci 2021; 63 (03) 212-216
  • 98 Bieger V, Thieringer FM, Fischer J, Rohr N. Fibroblast behavior on conventionally processed, milled, and printed occlusal device materials with different surface treatments. J Prosthet Dent 2023; 129 (06) 939-945
  • 99 Polychronakis N, Dimitriadi M, Polyzois G, Eliades G. The effect of cooling procedures on monomer elution from heat-cured polymethyl methacrylate denture base materials. J Appl Oral Sci 2022; 30: e20220161
  • 100 Turkyilmaz I, Wilkins GN. Denture teeth arrangement using a web-based digital software program: taking preclinical dental education to another level. J Dent Sci 2021; 16 (04) 1310-1311
  • 101 Prithviraj DR, Bhalla HK, Vashisht R, Sounderraj K, Prithvi S. Revolutionizing restorative dentistry: an overview. J Indian Prosthodont Soc 2014; 14 (04) 333-343
  • 102 Giugliano T, Chikunov I, Zhivago P, Jahangiri L. A digital method of teaching artificial teeth arrangement. J Dent Educ 2020; 85 (Suppl. 01) 904-906
  • 103 Jitwirachot K, Rungsiyakull P, Holloway JA, Jia-Mahasap W. Wear behavior of different generations of zirconia: present literature. Int J Dent 2022; 2022: 9341616
  • 104 Lauren M, McIntyre F. 4D clinical imaging for dynamic CAD. Int J Dent 2013; 2013: 690265
  • 105 Abdel Raheem IM, Hammad IA, Abel Kader SH, Fahmy RA. Fabrication of a CAD-CAM custom healing abutment guided by a conventional dental radiograph for delayed loaded dental implants: a dental technique. J Prosthet Dent 2022; 127 (01) 49-54
  • 106 Chen L, Li D, Zhou J, Lin WS, Tan J. Duplicating complete dentures with conventional and digital methods: comparisons of trueness and efficiency. Dent J 2022; 10 (03) 35
  • 107 Wu Y, Hu Z, Zhang X, Bai H, Sun Y, Fan B. Optimum design of reference points distribution in three-dimensional reconstruction of dental model in intercuspal position. BMC Oral Health 2021; 21 (01) 561
  • 108 Buduru S, Mesaros A, Talmaceanu D, Baru O, Ghiurca R, Cosgarea R. Occlusion in the digital era: a report on 3 cases. Med Pharm Rep 2019; 92 (Suppl. 03) S78-S84
  • 109 Singi SR, Sathe S, Reche AR, Sibal A, Mantri N. Extended arm of precision in prosthodontics: artificial intelligence. Cureus 2022; 14 (11) e30962
  • 110 Oweis Y, Ereifej N, Al-Asmar A, Nedal A. Factors affecting patient satisfaction with complete dentures. Int J Dent 2022; 2022: 9565320
  • 111 Furuchi M, Takeuchi Y, Kamimoto A, Koizumi H. Usage of English prosthodontic terms 2019 in Japan. J Oral Sci 2022; 64 (04) 322-323
  • 112 Abdulla MA. The effect of different levels of a network reinforced system and curing methods on properties of different acrylic resin denture base materials. J Int Soc Prev Community Dent 2022; 12 (06) 621-629
  • 113 de Oliveira E, Zancanaro de Figueiredo E, Spohr AM, Lima Grossi M. Properties of acrylic resin for CAD/CAM: a systematic review and meta-analysis of in vitro studies. J Prosthodont 2021; 30 (08) 656-664
  • 114 Snosi AM, Lotfy SM, Thabet YG, Sabet ME, Rizk FN. Subtractive versus additive indirect manufacturing techniques of digitally designed partial dentures. J Adv Prosthodont 2021; 13 (05) 327-332
  • 115 Bonnet G, Batisse C, Bessadet M, Nicolas E, Veyrune JL. A new digital denture procedure: a first practitioners appraisal. BMC Oral Health 2017; 17 (01) 155
  • 116 Zidan S, Silikas N, Haider J, Alhotan A, Jahantigh J, Yates J. Assessing tensile bond strength between denture teeth and nano-zirconia impregnated PMMA denture base. Int J Nanomedicine 2020; 15: 9611-9625
  • 117 da Fonseca GF, Dal Piva AMO, Tribst JPM, Borges ALS. Influence of restoration height and masticatory load orientation on ceramic endocrowns. J Contemp Dent Pract 2018; 19 (09) 1052-1057
  • 118 Becker K. 3D-printed materials dentistry. Appl Sci (Basel) 2022; 13 (01) 457
  • 119 Kim H, Jang W, Park C, Yun K-D, Lim H-P, Park S. Fabrication of complete denture using CAD-based vertical dimension increase and monolithic disc: a case report. J Dent Rehabil Appl Sci 2022; 38: 242-248
  • 120 Onbasi Y, Abu-Hossin S, Paulig M, Berger L, Wichmann M, Matta RE. Trueness of full-arch dental models obtained by digital and conventional impression techniques: an in vivo study. Sci Rep 2022; 12 (01) 22509
  • 121 Asli HN, Rahimabadi S, Belyani N, Asli MN, Falahchai M. Effect of different mechanical surface treatments on flexural strength of repaired denture base. J Oral Res 2022; 11: 1-10
  • 122 Khalil RT, Alshimy A, Elsherbini E, Abd-Ellah ME. The microbiological effect of virgin coconut oil on the morphological and volumetric dimensional changes of 3D printed surgical guides (in vitro study). BMC Oral Health 2022; 22 (01) 636
  • 123 Ayaz EA, Aladağ SÜ. Effect of cigarette smoke and denture cleansers on the surface properties and color stability of CAD-CAM and conventional denture base resins. Dent Mater J 2023; 42 (02) 167-176
  • 124 Dimitrova M, Capodiferro S, Vlahova A. et al. Spectrophotometric analysis of 3D printed and conventional denture base resin after immersion in different colouring agents: an in vitro study. Appl Sci (Basel) 2022; 12 (24) 12560
  • 125 Neves CB, Chasqueira AF, Rebelo P, Fonseca M, Portugal J, Bettencourt A. Microhardness and flexural strength of two 3D-printed denture base resins. Revista Portuguesa de Estomatologia. Med Dent Cir Maxilofac 2022; 63: 198-203
  • 126 Kuralt M, Bukleta MS, Kuhar M, Fidler A. A novel digital method for evaluation of mucosa thickness changes in time: changes associated with a removable partial denture. Image Anal Stereol 2022; 41 (03) 181-191
  • 127 Saleh O, Nozaki K, Matsumura M, Yanaka W, Miura H, Fueki K. Texture-based neural network model for biometric dental applications. J Pers Med 2022; 12 (12) 1954
  • 128 Chen T, Jinno Y, Atsuta I. et al. Current surface modification strategies to improve the binding efficiency of emerging biomaterial polyetheretherketone (PEEK) with bone and soft tissue: a literature review. J Prosthodont Res 2023; 67 (03) 337-347
  • 129 Wei X, Wang M, Pan Y. et al. Influence of fabrication method on the biological properties of modified PEEK. Dent Mater J 2023; 42 (01) 72-78
  • 130 Milinkovic I, Krasavcevic AD, Jankovic S, Sopta J, Aleksic Z. Immunohistochemical analysis of soft tissue response to polyetheretherketone (PEEK) and titanium healing abutments on dental implants: a randomized pilot clinical study. BMC Oral Health 2022; 22 (01) 484
  • 131 Khalifa FT, Hassanein A, Hamza TA. Biofilm adhesion and surface roughness of PEEK vs monolithic zirconium: comparative “an in-vitro study.”. J Fundam Clin Res 2022; 2: 157-169
  • 132 Alshehri A, Almutairi B, Jurado CA. et al. Biomimetic whitening effect of polyphosphate-bleaching agents on dental enamel. Biomimetics (Basel) 2022; 7 (04) 183
  • 133 Abdullah Alsadon O. Adhesion concepts and techniques for laboratory-processed indirect dental restorations. Saudi Dent J 2022; 34 (08) 661-668
  • 134 Bak SY, Saglik B, Inglehart MR. Introducing dental students to complete denture treatment in times of COVID-19: students' responses. J Dent Educ 2023; 87 (03) 313-325
  • 135 Mazurek-Popczyk J, Nowicki A, Arkusz K, Pałka Ł, Zimoch-Korzycka A, Baldy-Chudzik K. Evaluation of biofilm formation on acrylic resins used to fabricate dental temporary restorations with the use of 3D printing technology. BMC Oral Health 2022; 22 (01) 442
  • 136 Lee HB, Bea EJ, Lee WS, Kim JH. Trueness of stereolithography ZrO2 crowns with different build directions. Dent Mater J 2023; 42 (01) 42-48
  • 137 Awajah M, Abbas N, Osman R. Evaluation of fracture resistance of 3D-printed implant retained overdenture with two different build angles. (An in-vitro study). Egypt Dent J 2022; 68: 3495-3502
  • 138 Alfouzan AF, Alotiabi HM, Labban N, Al-Otaibi HN, Al Taweel SM, AlShehri HA. Erratum: Color stability of 3D-printed denture resins: effect of aging, mechanical brushing and immersion in staining medium. J Adv Prosthodont 2022; 14 (05) 334-334
  • 139 Wu Q, Zhang N, Dong B, Sun M, Yang X, Yu H. Esthetic rehabilitation for a Kennedy class IV patient using detachable 3D printing diagnostic denture and removable partial denture with polyetheretherketone framework. Heliyon 2022; 8 (10) e10834
  • 140 Yang Y, Zhu X, Wang Z, Liu X, Tan J, Wang Y. A digital workflow for single complete denture using a multi-functional diagnostic denture. J Dent Sci 2023; 18 (02) 889-892
  • 141 Zoidis P, Motlagh N, Tarte S. et al. Dental students' perspectives on three intraoral scanners and CAD/CAM systems before and after a pre-clinical elective course in digital dentistry. J Clin Exp Dent 2022; 14 (10) e803-e808
  • 142 Park D-H, Bae E-B, Jung I-H. et al. 3D printed interim immediate denture by using the occlusal plane digital transfer method of the POP BOW system in a patient planning to extract upper and lower residual teeth: a case report. J Dent Rehabil Appl Sci 2022; 38: 178-188
  • 143 Mayta-Tovalino F, Fernandez-Giusti A, Mauricio-Vilchez C, Barja-Ore J, Guerrero ME, Retamozo-Siancas Y. The abrasive and remineralising efficacy of coturnix eggshell. Int Dent J 2022; 72 (06) 792-796
  • 144 Alsayed HD. Misfit of implant-supported zirconia (Y-TZP) CAD-CAM framework compared to non-zirconia frameworks: a systematic review. Medicina (Kaunas) 2022; 58 (10) 1347
  • 145 Artopoulou II, Pachiou A, Zachari E, Niarchou T, Athanasiades C, Anastassiadou V. The psychological disturbance associated with tooth loss questionnaire revisited: validation on a national Greek sample. Appl Sci (Basel) 2022; 12 (19) 9617
  • 146 Hellyer P. Analysis of different workflows for denture construction. Br Dent J 2022; 233 (03) 218
  • 147 Hellyer P. 3D printed temporary restorations are stronger. Br Dent J 2022; 233 (03) 218
  • 148 Hancocks Obe S. Putting the “it” in digital. Br Dent J 2022; 233 (02) 67
  • 149 Hellyer P. Milling produces best-fitting denture bases. Br Dent J 2022; 233 (03) 218
  • 150 Quinzi V, Polizzi A, Ronsivalle V. et al. Facial scanning accuracy with stereophotogrammetry and smartphone technology in children: a systematic review. Children (Basel) 2022; 9 (09) 1390
  • 151 Sayed ME, Porwal A, Jain S. et al. Linear dimensional change in acrylic denture teeth positions factored by different processing techniques and occlusal forms: an in vitro study. Appl Sci (Basel) 2022; 12 (14) 7058
  • 152 Mohammed E, ElHameed HA. Comparative laboratory investigation for the effect of thermo-mechanical stresses on mandibular denture base deformation for 3D printed and conventional dentures. Egypt Dent J 2022; 68: 2465-2477
  • 153 Nazar SA, Nair VV, K HK, Ravichandran R. VS D, H. Effect of disinfection on shear bond strength between heat activated acrylic resin denture base and commercially available denture teeth: an in vitro study. Int J Appl Dent Sci 2022; 8: 348-355
  • 154 Zeidan A, El-Rahim RA, Helal M. Evaluation for elastic modulus of CAD-CAM milled and 3D printed denture base resins. Al-Azhar J Dent Sci 2022; 25: 241-246
  • 155 Saygın AG, Yıldırımoğlu M. Comparison of microhardness of artificial teeth with different contents after waiting in various liquids. Cumhur Dent J 2022; 25: 111-116
  • 156 Arafa A, Emam M. Effect of repeated heat pressing on fracture resistance and mode of failure of polyetheretherketone (PEEK) three-unit fixed dental prosthesis (FDP). Egypt Dent J 2022; 68: 2531-2542
  • 157 Hussein MO, Hussein LA. Trueness of 3D printed partial denture frameworks: build orientations and support structure density parameters. J Adv Prosthodont 2022; 14 (03) 150-161
  • 158 Choudhry Z, Malik S, Mirani ZA. et al. Antifungal efficacy of sodium perborate and microwave irradiation for surface disinfection of polymethyl methacrylate polymer. Appl Sci (Basel) 2022; 12 (14) 7004
  • 159 Beatriz Vilela Teixeira A, Greghi de Carvalho G, Cândido Dos Reis A. Incorporation of antimicrobial agents into dental materials obtained by additive manufacturing: a literature review. Saudi Dent J 2022; 34 (06) 411-420
  • 160 Helal E, Esmat AM, Elawady AF, Khalil FF. Influence of denture adhesives on oral health quality of life, occlusion and disocclusion times of digitally fabricated and designed removable complete dentures (clinical cross over study). Int J Adv Res (Indore) 2022; 10: 696-706
  • 161 Babaee Hemmati Y, Neshandar Asli H, Falahchai M, Safary S. Effect of different surface treatments and orthodontic bracket type on shear bond strength of high-translucent zirconia: an in vitro study. Int J Dent 2022; 2022: 9884006
  • 162 Nassar HI, Abdelaziz MS. Retention of bar clip attachment for mandibular implant overdenture. BMC Oral Health 2022; 22 (01) 227
  • 163 Alshahrani FA, Hamid SK, Alghamdi LA. et al. Impact of polymerization technique and ZrO2 nanoparticle addition on the fracture load of interim implant-supported fixed cantilevered prostheses in comparison to CAD/CAM material. Dent J 2022; 10 (06) 102
  • 164 Behairy N, Kabeel S, El-Sadany H. Evaluation of retention for maxillary complete denture constructed by conventional and 3D printing techniques. Al-Azhar Dent J Girls 2022; 9: 245-250
  • 165 Delrieu J, Joniot S, Vergé T, Destruhaut F, Nasr K, Canceill T. The use of PEEK as an occlusal splint in a patient with histaminosis: a case report. Spec Care Dentist 2022; 42 (06) 646-650
  • 166 Mine A. Adhesive dentistry in prosthodontics: the key to open minimal intervention and full-digital treatment. J Prosthodont Res 2022; 66 (02) vi-vii
  • 167 Scribante A, Gallo S, Pascadopoli M. et al. Properties of CAD/CAM 3D printing dental materials and their clinical applications in orthodontics: where are we now?. Appl Sci (Basel) 2022; 12: 551
  • 168 Kaku M. The academic value of JPR is steadily increasing. J Prosthodont Res 2022; 66 (04) vi-vii
  • 169 Wang Q, Zhang Y, Li Q. et al. Therapeutic applications of antimicrobial silver-based biomaterials in dentistry. Int J Nanomed 2022; 17: 443-462
  • 170 Alkhodary M. Zirconia versus cobalt chromium meshwork reinforcement of implant-assisted mandibular overdenture. Egypt Dent J 2022; 68: 787-794
  • 171 Sabbah A, Romanos G, Delgado-Ruiz R. Extended post-curing light exposure and sandblasting effects on surface hydrophobicity of 3D-printed denture base resin. Prosthesis 2022; 4: 80-90
  • 172 Nulty A. A comparison of trueness and precision of 12 3D printers used in dentistry. BDJ Open 2022; 8 (01) 14
  • 173 Elhelbawy NG, Ghouraba RF, Hasaneen FA. A comparative evaluation of the radiopacity of contemporary restorative CAD/CAM blocks using digital radiography based on the impact of material composition. Int J Biomater 2022; 2022: 4131176
  • 174 Guddu G. A study on application of prosthodontic techniques in private practice: a survey. Univ J Dent Sci 2021; 8 (01) 18-26
  • 175 Gülsoy M, Tuna SH, Pekkan G. Evaluation of median mandibular flexure values in dentulous and edentulous subjects by using an intraoral digital scanner. J Adv Prosthodont 2022; 14 (01) 32-44
  • 176 Kaddas C, Papamanoli E, Bobetsis YA. Etiology and treatment of peri-implant soft tissue dehiscences: a narrative review. Dent J 2022; 10 (05) 86
  • 177 Panagiotis N, Kalliopi P, Spyridon V, Efstratios P. Multidisciplinary management of a compromised dentition, implementing a combination of digital workflows. J Dent 2022; 121: 104038
  • 178 El-Hefnawy W, Ahmed A, El-Mekkawi W. Fracture resistance of CAD/CAM fabricated polyetheretherketone (PEEK) endocrowns and post retained crowns with two preparation designs. Al-Azhar Dent J Girls 2022; 9: 225-233
  • 179 Natalia DP, Roberta P, Carlo M, Giovanna I. Hydroxyapatite/tricalcium phosphate (HA/beta-TCP) scaffold combined with bone and endothelial cells as a potential candidate for oral and maxillofacial bone regeneration. J Dent 2022; 121: 103960
  • 180 Hussein M, Elkady A, Alsharkawy M. Evaluation of digital smile design for closure of maxillary median diastema with porcelain laminate veneers (clinical trial). Alex Dent J 2022; 47 (02) 173-180
  • 181 Wen C, Ye H, Chen H, Zhou Y, Huang M, Sun Y. Biometry of width between labial transitional line angles in anterior teeth: an observational study. J Adv Prosthodont 2022; 14 (01) 1-11
  • 182 Güleryüz A, Korkmaz C, Şener A, Taş MO. The effect of thermo-mechanical fatigue on the retentive force and dimensional changes in polyetheretherketone clasps with different thickness and undercut. J Adv Prosthodont 2021; 13 (05) 304-315
  • 183 Rahlf B, Korn P, Zeller A-N. et al. Novel approach for treating challenging implant-borne maxillary dental rehabilitation cases of cleft lip and palate: a retrospective study. Int J Implant Dent 2022; 8 (01) 6
  • 184 Sauer DG, Rahbeeni DR, Fredeman Calitz B. Guided maxillary full-arch implant rehabilitation using a novel chrome cobalt alveolar bone reduction guide. J Dent 2022; 121: 104037
  • 185 Kortam S, Abdeen RM. Treatment outcomes of indirect versus direct digitally constructed complete dentures as compared to conventionally constructed complete dentures: cross-over clinical study. Egypt Dent J 2022; 68: 1741-1756
  • 186 Doh RM, Kim JE, Nam NE, Shin SH, Lim JH, Shim JS. Evaluation of dimensional changes during postcuring of a three-dimensionally printed denture base according to the curing time and the time of removal of the support structure: an in vitro study. Appl Sci (Basel) 2021; 11: 10000
  • 187 Vasudeva D, Gulati M, Kumar MS. Steps in digital denture fabrication. Int J Health Sci (Qassim) 2021; 5 (S3): 315-319
  • 188 Parameswari BD, Ranjith RHA, Sekar V. S D. Virtual yet veritable: digital dentures. IP Ann Prosthodont Restor Dent 2022; 8: 32-37
  • 189 Elboraey A, El Naggar S, Helal E, Khalil M, Esmat A. Color stability of heat polymerized complete dentures and 3D printed CAD/CAM dentures: a cross-over clinical study. J Arab Soc Med Res 2022; 17: 139
  • 190 Enkling N, Marder M, Bayer S, Götz W, Stoilov M, Kraus D. Soft tissue response to different abutment materials: a controlled and randomized human study using an experimental model. Clin Oral Implants Res 2022; 33 (06) 667-679
  • 191 Elgabry HS, Eissa SM, Heikal MA. Digital occlusal analysis and oral health-related quality of life of patients with 3D printed complete dentures versus conventional dentures. Int J Adv Res (Indore) 2021; 9: 210-221
  • 192 Dohiem M. Comparison of bond strength between acrylic based soft liner and two different denture bases (3Dprinted and conventional denture base). Egypt Dent J 2022; 68: 659-663
  • 193 Kobe T, Fidler A, Kuralt M, Gašperšič R. A novel Snap-FIT implant surgical guide design: proof of principle and pre-clinical evaluation. J Dent 2022; 121: 103961
  • 194 Huang L, Nemoto R, Okada D. et al. Investigation of stress distribution within an endodontically treated tooth restored with different restorations. J Dent Sci 2022; 17 (03) 1115-1124
  • 195 Romalee W, Kettratad M, Trang TTN, Wang DH, Chen JE, Hsu ML. Evaluation of the potential denture covering area in buccal shelf with intraoral scanner. J Dent Sci 2022; 17 (03) 1335-1341
  • 196 Raffone C, Gianfreda F, Pompeo MG, Antonacci D, Bollero P, Canullo L. Chairside virtual patient protocol. Part 2: management of multiple face scans and alignment predictability. J Dent 2022; 122: 104123
  • 197 Fiore AD, Meneghello R, Brun P. et al. Comparison of the flexural and surface properties of milled, 3D-printed, and heat polymerized PMMA resins for denture bases: an in vitro study. J Prosthodont Res 2022; 66 (03) 502-508
  • 198 Alshamrani AA, Raju R, Ellakwa A. Effect of printing layer thickness and postprinting conditions on the flexural strength and hardness of a 3D-printed resin. BioMed Res Int 2022; 2022: 8353137
  • 199 Legaz J, Sailer I, Mojon P, Lee H, Karasan D. Mechanical properties of additively manufactured and milled interim 3-unit fixed dental prostheses. J Prosthodont 2023; 32 (03) 234-243
  • 200 Hazra R, Srivastava A, Kumar D. Faster, convenient & effective: the single appointment complete denture: a new dental technique. Int Dent J Stud Res 2022; 10: 18-21
  • 201 Motoyoshi M. Special issue on current techniques and materials in dentistry. Appl Sci (Basel) 2022; 12 (09) 4439
  • 202 Joksimović E, Šćepanović M, Staletović D, Pejić-Duspara M, Bijelić B, Đorđević V. Lithium disilicate and PEEK implant-retained single crowns: a randomized, prospective clinical study. Srp Arh Celok Lek 2022; 150: 23-28
  • 203 Géczi Z, Róth I, Hermann P. Esthetic rehabilitation of anterior teeth with “copy-paste” concept: a case report. J Dent 2022; 121: 104036
  • 204 Tribst JPM, Campanelli de Morais D, Melo de Matos JD. et al. Influence of framework material and posterior implant angulation in full-arch all-on-4 implant-supported prosthesis stress concentration. Dent J 2022; 10 (01) 12
  • 205 Zwaan J, Minutolo DTV. Guided perio-prosthodontic rehabilitation of heavy bruxists. J Dent 2022; 121: 103962
  • 206 Dohiem M. Accuracy of fit of all on-four prosthesis constructed from 3D printing and milling technologies. Egypt Dent J 2022; 68: 677-682
  • 207 Egusa H. JPR starts 2022 with a new design: towards a new frontier in prosthodontics. J Prosthodont Res 2022; 66 (01) vi-vii
  • 208 Cho S-Y, Song Y-G. A comparison study on shear bond strength of 3D printed resin and conventional heat-cured denture base resin to denture relining materials. J Dent Rehabil Appl Sci 2021; 37: 232-243
  • 209 Abdelaziz SM, Altonbary GY, El Mekawy N, Hegazy SA. Impact of locator attachments with different retentive insert materials on bite force in mandibular implant overdenture. Egypt J Oral Maxillofac Surg 2021; 12: 245-254
  • 210 Mendes JM, Botelho PC, Mendes J, Barreiros P, Aroso C, Silva AS. Comparison of fracture strengths of three provisional prosthodontic CAD/CAM materials: laboratory fatigue tests. Appl Sci (Basel) 2021; 11 (20) 9589
  • 211 Mai HN, Lee DH. Effects of artificial extraoral markers on accuracy of three-dimensional dentofacial image integration: smartphone face scan versus stereophotogrammetry. J Pers Med 2022; 12 (03) 490
  • 212 Darwish E, Helmy M. Effect of nanoparticles on surface roughness of digitally and conventionally constructed RPD framework. Egypt Dent J 2022; 68: 1731-1739
  • 213 Zakhary M, Sayed el M, El-Hamid HA, Eltamimi K. Effect of zirconium oxide nano-fillers on dimensional accuracy of acrylic resin maxillary complete dentures: an in vitro study. Dent Sci Updates 2022; 3: 85-91
  • 214 Prause E, Hey J, Beuer F, Schmidt F. Wear resistance of 3D-printed materials: a systematic review. Dent Rev 2022; 2: 100051
  • 215 Montero J, Guadilla Y, Flores J. et al. Patient-centered treatment outcomes with full-arch PEEK rehabilitation supported on four immediate or conventionally loaded implants. a randomized clinical trial. J Clin Med 2021; 10 (19) 4589
  • 216 Al Moaleem MM, Al-layl OA, Alhomood MA. et al. Computer engineering complete dentures workflow: systematic techniques review. J Pharm Res Int 2021; 33 (43A): 207-220
  • 217 Gellrich NC, Rahlf B, Zimmerer R, Pott PC, Rana M. A new concept for implant-borne dental rehabilitation; how to overcome the biological weak-spot of conventional dental implants?. Head Face Med 2017; 13 (01) 17
  • 218 Jung S, Park C, Yang HS. et al. Comparison of different impression techniques for edentulous jaws using three-dimensional analysis. J Adv Prosthodont 2019; 11 (03) 179-186
  • 219 Paryag A, Rafeek RN, Meighan A. Using a simple chair-side copy denture technique in the AvaDent digital denture process: a case report and review. Open J Stomatol 2018; 08: 241-249
  • 220 Maltar M, Miloš L, Milardović S. et al. Attitudes of the Students from the School of Dental Medicine in Zagreb towards CAD/CAM. Acta Stomatol Croat 2018; 52 (04) 322-329
  • 221 Unkovskiy A, Wahl E, Zander AT, Huettig F, Spintzyk S. Intraoral scanning to fabricate complete dentures with functional borders: a proof-of-concept case report. BMC Oral Health 2019; 19 (01) 46
  • 222 Andreescu CF, Ghergic DL, Botoaca O, Hancu V, Banateanu AM, Patroi DN. Evaluation of different materials used for fabrication of complete digital denture. Mater Plast 2018; 55: 124-128
  • 223 Millet C, Virard F, Lienhart G, Ducret M. Digital prosthodontic management of a young patient with Papillon-Lefèvre syndrome: a clinical report. J Prosthet Dent 2020; 123 (04) 548-552
  • 224 Oberoi G, Nitsch S, Edelmayer M, Janjić K, Müller AS, Agis H. 3D printing-encompassing the facets of dentistry. Front Bioeng Biotechnol 2018; 6: 172
  • 225 Pedram P, Kermanshah H, Nejatbakhsh R, Omrani LR, Rafiezadeh S. Esthetic perception of recurring esthetic dental proportion in different lip line positions among lay people. J Islam Dent Assoc Iran 2019; 31: 21-25
  • 226 Stawarczyk B, Lümkemann N, Eichberger M, Wimmer T. Accuracy of digitally fabricated wax denture bases and conventional completed complete dentures. Dent J 2017; 5 (04) 36
  • 227 El-Sherbini NN, Helmy MA. Effect of sandblasting on cadmium free complete denture retention. Egypt Dent J 2018; 64: 1607-1612
  • 228 Elsayed A, El Din AS, AbuElmagd IAR. Evaluating dimension accuracy of three differently fabricated denture base materials. Egypt Dent J 2019; 65: 2635-2640
  • 229 Kim J-H, Kim J-E, Park YB, Lee K-W. Use of digital scan data for evaluation of edentulous ridge relationship: a case report for removable prosthesis with unilateral cross bite. Taehan Chikwa Pochol Hakhoe Chi 2019; 57: 304
  • 230 Deng K, Chen H, Zhao Y, Zhou Y, Wang Y, Sun Y. Evaluation of adaptation of the polylactic acid pattern of maxillary complete dentures fabricated by fused deposition modelling technology: a pilot study. PLoS One 2018; 13 (08) e0201777
  • 231 Cristache CM, Totu EE, Grosu AR, Ene O, Beuran IA, Burlibasa M. Nanocomposite for rapid prototyped complete denture eighteen months follow-up on clinical performance. Revista de Chimie 2019; 70: 387-392
  • 232 Mohamed MN, Mohamed GF, Hassan NO. Comparative evaluation of physical properties of conventionally constructed versus CAD/CAM milled frameworks for Kennedy class I partial dentures. Egypt Dent J 2019; 65: 3663-3670
  • 233 Gomaa AM. Strains induced in CAD/CAM milled mandibular implant retained overdentures in vivo strain gauge analysis. Egypt Dent J 2019; 65: 2931-2944
  • 234 Özcan M, Höhn J, de Araújo GM, Moura DMD, Souza ROA. Influence of testing parameters on the load-bearing capacity of prosthetic materials used for fixed dental prosthesis: a systematic review and meta-analysis. Braz Dent Sci 2018; 21: 470-490
  • 235 Donovan TE, Marzola R, Murphy KR. et al. Annual review of selected scientific literature: a report of the Committee on Scientific Investigation of the American Academy of Restorative Dentistry. J Prosthet Dent 2018; 120 (06) 816-878
  • 236 Srinivasan M, Kalberer N, Maniewicz S, Müller F. Implant overdentures retained by self-aligning stud-type attachments: a clinical report. J Prosthet Dent 2020; 123 (01) 6-14
  • 237 Mai HY, Choi Y-D, Lee D-H. Digital approach integrating 3D facial scan and a virtual mockup for esthetic restorative treatment: a case report. Taehan Chikwa Pochol Hakhoe Chi 2019; 57: 425
  • 238 Ariani N. Tooth replacement and nutrition in older people: is there a future for traditional removable prosthodontics?. J Indian Prosthodont Soc 2018; 18 (Suppl. 01) S5-S6
  • 239 Yengopal V. What's new for the clinician - excerpts from and summaries of recently published papers (October 2018). S Afr Dent J 2018; 73 (Suppl. 09) 580-583
  • 240 Jayaraman S, Singh BP, Ramanathan B, Pazhaniappan Pillai M, MacDonald L, Kirubakaran R. Final-impression techniques and materials for making complete and removable partial dentures. Cochrane Database Syst Rev 2018; 4 (04) CD012256
  • 241 Gomaa AM. Chewing and bite force efficiency of innovative implant assisted overdentures. Egypt Dent J 2019; 65: 2981-2992
  • 242 Saad YM, Abdelhamid AM, ElShabrawy SM. Laboratory evaluation of pre-polymerized denture base material used for CAD/CAM complete denture manufacturing. Alex Dent J 2018; 43: 94-101
  • 243 Lee J-S, Ahn S-J, Leesungbok R, Lee S-W. A case of removable dentures using digital method. Taehan Chikwa Pochol Hakhoe Chi 2018; 56: 250
  • 244 Mangano F, Margiani B, Admakin O. A novel full-digital protocol (SCAN-PLAN-MAKE-DONE®) for the design and fabrication of implant-supported monolithic translucent zirconia crowns cemented on customized hybrid abutments: a retrospective clinical study on 25 patients. Int J Environ Res Public Health 2019; 16 (03) 317
  • 245 Tavares CC, Freire JCP, Freire SCP, Dias-Ribeiro E, Batista AUD. Aplicabilidade dos sistemas CAD/CAM em prótese total: revisão de literatura. Arch Health Invest 2019; 7 (11) 482-485
  • 246 Hassan B, Greven M, Wismeijer D. Integrating 3D facial scanning in a digital workflow to CAD/CAM design and fabricate complete dentures for immediate total mouth rehabilitation. J Adv Prosthodont 2017; 9 (05) 381-386
  • 247 2019 ADEA Annual Session: poster abstracts. J Dent Educ 2019; 83 (02) 188-241
  • 248 Kholief DM, Kabeel SM. Assessment of microbial adherence on conventional and CAD/CAM complete denture. Al-Azhar Dent J Girls 2019; 6: 9-17
  • 249 Nihei T, Ohashi K, Hattori M, Imazato S. A surveillance study of the demand of titanium and titanium alloys in Japan. Dent Mater J 2020; 39 (01) 9-11
  • 250 Jung Y, Lee J, Hong S-J, Noh K, Kim H-S, Pae A. Fabrication of complete dentures by conventional method and CAD/CAM milling: a case report. Taehan Chikwa Pochol Hakhoe Chi 2019; 57: 296
  • 251 Metwally AF. Comparison of patient satisfaction & occlusal force distribution pattern in CAD/ CAM and conventional complete dentures using the T-scan III computerized occlusal analysis system. (RCT). Egypt Dent J 2019; 65: 2641-2649
  • 252 Federation FWD. Abstracts of the 106th, FDI World Dental Congress, September 2018. Int Dent J 2018; 68 (Suppl. 02) 2-134
  • 253 Lee Y, Kwon K-R, Pae A, Noh K, Paek J, Hong S-J. Rehabilitation of fully edentulous patient using Ceramill full denture system (FDS). Taehan Chikwa Pochol Hakhoe Chi 2019; 57: 232
  • 254 Cagna DR, Donovan TE, McKee JR. et al. Annual review of selected scientific literature: a report of the Committee on Scientific Investigation of the American Academy of Restorative Dentistry. J Prosthet Dent 2019; 122 (03) 198-269
  • 255 Kamalakidis SN, Anastassiadou V, Sofou A, Pissiotis A. Success of complete denture treatment, detailed investigation of construction protocols, occlusal schemes and evaluation questionnaires. Balk J Dent Med 2018; 22: 115-122
  • 256 Zarone F, Di Mauro MI, Ausiello P, Ruggiero G, Sorrentino R. Current status on lithium disilicate and zirconia: a narrative review. BMC Oral Health 2019; 19 (01) 134
  • 257 Kim H-A, Lim H-P, Kang H, Yang H-S, Park S-W, Yun K-D. Fabrication of additive manufacturing interim denture and comparison with conventional interim denture: a case report. Taehan Chikwa Pochol Hakhoe Chi 2019; 57: 483
  • 258 Mohamed MD, Shaheen NH. Comparative evaluation of the masticatory muscleS activity with CAD/CAM versus conventional complete denture using electromyography. Egypt Dent J 2019; 65: 3829-3836
  • 259 Schimmel M, Akino N, Srinivasan M, Wittneben JG, Yilmaz B, Abou-Ayash S. Accuracy of intraoral scanning in completely and partially edentulous maxillary and mandibular jaws: an in vitro analysis. Clin Oral Investig 2021; 25 (04) 1839-1847
  • 260 Schlenz MA, Schubert V, Schmidt A, Wöstmann B, Ruf S, Klaus K. Digital versus conventional impression taking focusing on interdental areas: a clinical trial. Int J Environ Res Public Health 2020; 17 (13) 1-12
  • 261 Perea-Lowery L, Gibreel M, Vallittu PK, Lassila L. Characterization of the mechanical properties of CAD/CAM polymers for interim fixed restorations. Dent Mater J 2020; 39 (02) 319-325
  • 262 Albuquerque IS, Freitas-Pontes KM, de Souza RF. et al. Is a two-step impression mandatory for complete denture fabrication on the severely resorbed mandible? A randomized trial on mastication, patient satisfaction and adjustments. J Dent 2020; 99: 103357
  • 263 Papathanasiou I, Kamposiora P, Papavasiliou G, Ferrari M. The use of PEEK in digital prosthodontics: a narrative review. BMC Oral Health 2020; 20 (01) 217
  • 264 Atri F, Azizi S, Hatampour S. Removable prosthetic treatment of an ectodermal dysplasia patient: a case report. J Craniomaxillofac Res 2020; 7 (01) 34-39
  • 265 Giannetti L, Apponi R, Dello Diago AM, Jafferany M, Goldust M, Sadoughifar R. Papillon-Lefèvre syndrome: oral aspects and treatment. Dermatol Ther 2020; 33 (03) e13336
  • 266 Kamble S, Jankar A, Somwanshi P, Pawar S, Vaybase V. Rejuvenating edentulism using CAD-CAM technology: a comprehensive review. Int J Adv Res (Indore) 2020; 8: 1233-1243
  • 267 Ortensi L, Vitali T, Bonfiglioli R, Grande F. New tricks in the preparation design for prosthetic ceramic laminate veneers. Prosthesis 2019; 1: 29-40
  • 268 Lee D-H, Lee J-S. Comparison of flexural strength according to thickness between CAD/CAM denture base resins and conventional denture base resins. J Dent Rehabil Appl Sci 2020; 36: 183-195
  • 269 Pattanaik S, Kakapoyil AS, Pattanaik BK. A method of fabricating two piece hollow obturator by using combination of rapid prototyping and conventional compression moulding technique: a case report. IP Ann Prosthodont Restor Dent 2020; 6: 167-170
  • 270 Algazar AE, Helal MA, Masoud MA, Fayad MI. Tensile bond strength of acrylic and composite denture teeth to milled CAD/CAM resins. Al-Azhar J Dent Sci 2020; 23: 335-342
  • 271 Nsaif R, Bayindir F. How can digital dentistry affect geriatric patient's treatment?. Int J Appl Dent Sci 2020; 6: 430-434
  • 272 Micovic D, Mayinger F, Bauer S, Roos M, Eichberger M, Stawarczyk B. Is the high-performance thermoplastic polyetheretherketone indicated as a clasp material for removable dental prostheses?. Clin Oral Investig 2021; 25 (05) 2859-2866
  • 273 Rutkunas V, Borusevicius R, Liaudanskaite D. et al. The effect of different cleaning protocols of polymer-based prosthetic materials on the behavior of human gingival fibroblasts. Int J Environ Res Public Health 2020; 17 (21) 1-17
  • 274 Mayinger F, Micovic D, Schleich A, Roos M, Eichberger M, Stawarczyk B. Retention force of polyetheretherketone and cobalt-chrome-molybdenum removable dental prosthesis clasps after artificial aging. Clin Oral Investig 2021; 25 (05) 3141-3149
  • 275 AlZaher ZA, Almaskin DF, Qaw MS. et al. Chemo-mechanical approach to improve repair bond strength of denture teeth. Int J Dent 2020; 2020: 8870361
  • 276 Oancea L, Burlibasa M, Petre AE, Panaitescu E, Cristache CM. Predictive model for occlusal vertical dimension determination and digital preservation with three-dimensional facial scanning. Appl Sci (Basel) 2020; 10: 1-15
  • 277 Pani E, Sarafianou A, Chalazoniti A, Artopoulou II, Polyzois G. Conventional vs simplified complete dentures. Stomatology Edu J 2021; 8: 261-274
  • 278 You SM, You SG, Lee BI, Kim JH. Evaluation of trueness in a denture base fabricated by using CAD-CAM systems and adaptation to the socketed surface of denture base: an in vitro study. J Prosthet Dent 2022; 127 (01) 108-114
  • 279 Ahmed KE, Peres KG, Peres MA, Evans JL, Quaranta A, Burrow MF. Operators matter: an assessment of the expectations, perceptions, and performance of dentists, postgraduate students, and dental prosthetist students using intraoral scanning. J Dent 2021; 105: 103572
  • 280 Mai HN, Lee DH. The effect of perioral scan and artificial skin markers on the accuracy of virtual dentofacial integration: stereophotogrammetry versus smartphone three-dimensional face-scanning. Int J Environ Res Public Health 2020; 18 (01) 1-12
  • 281 Teng R, Meng Y, Zhao X. et al. Combination of polydopamine coating and plasma pretreatment to improve bond ability between PEEK and primary teeth. Front Bioeng Biotechnol 2021; 8: 630094
  • 282 ElHameed HA, Mohamed S. Comparative laboratory evaluation of dimensional accuracy for 3D-printed complete maxillary denture. Egypt Dent J 2021; 67: 661-668
  • 283 Fueki K, Inamochi Y, Wada J. et al. A systematic review of digital removable partial dentures. Part I: clinical evidence, digital impression, and maxillomandibular relationship record. J Prosthodont Res 2022; 66 (01) 40-52
  • 284 Kanakaraj SKHK, Ravichandran R. An update on CAD/CAM removable complete dentures: A review on different techniques and available CAD/CAM denture systems. Int J Appl Dent Sci 2021; 7: 491-498
  • 285 Kamal M. Evaluation of surface micro-hardness and fracture toughness of conventionally constructed versus CAD/CAM constructed denture base materials: an in-vitro study. Egypt Dent J 2021; 67: 757-765
  • 286 Papadopoulos I, Fuller J. Restoration of localised erosive wear using a combination of dental materials: a conservative approach. Br Dent J 2021; 230 (05) 294-300
  • 287 Benli M, Eker-Gümüş B, Kahraman Y, Huck O, Özcan M. Can polylactic acid be a CAD/CAM material for provisional crown restorations in terms of fit and fracture strength?. Dent Mater J 2021; 40 (03) 772-780
  • 288 Süpple J, von Glasenapp J, Hofmann E, Jost-Brinkmann PG, Koch PJ. Accurate bracket placement with an indirect bonding method using digitally designed transfer models printed in different orientations: an in vitro study. J Clin Med 2021; 10 (09) 2002
  • 289 Al-Otaibi HN. Monomer leakage behavior of conventional and CAD/CAM denture acrylic materials under different pH values. Biosci Biotechnol Res Commun 2021; 14: 110-117
  • 290 Aly MD. Fracture incidence in implant-retained mandibular overdenture constructed by either conventional method or CAD/CAM technology: a one year follow up. Egypt Dent J 2021; 67: 1417-1422
  • 291 Alkhodary MA. Optical versus conventional impressions of the completely edentulous arches. Egypt Dent J 2021; 67: 1407-1415
  • 292 Han CG, Park YB, Shim JS, Kim JE. Restorative space analysis by jaw motion tracking using a template in completely edentulous patients. Appl Sci (Basel) 2021; 11 (03) 3933
  • 293 Rasaie V, Abduo J, Hashemi S. Accuracy of intraoral scanners for recording the denture bearing areas: a systematic review. J Prosthodont 2021; 30 (06) 520-539
  • 294 Fawzy AM, Abdelrahim RA, Hameed BA. Assessment of hardness, flexural modulus, and bond strength of acrylic denture bases fabricated by 3D digital methods. Egypt Dent J 2021; 67: 2559-2566
  • 295 Pasricha N, Aggarwal K. Digitalization of conventional removable prosthesis: CAD-CAM dentures. J Dent Sci 2021; 7 (03) 150-154
  • 296 Lee HJ, Jeon J, Moon HS, Oh KC. Digital workflow to fabricate complete dentures for edentulous patients using a reversing and superimposing technique. Appl Sci (Basel) 2021; 11 (03) 5786
  • 297 Shaikh SS, Nahar P, Shaikh SY, Sayed AJ, Ali Habibullah M. Current perspectives of 3D printing in dental applications. Braz Dent Sci 2021; 24 (03) 1-9
  • 298 Garg S, Tushar, Chaudhary A, Arora S. Unconventional denture fabrication technique for patient with increased vertical dimension: an innovative alternative. Int J Appl Dent Sci 2021; 7: 97-102
  • 299 Batisse C, Nicolas E. Comparison of CAD/CAM and conventional denture base resins: a systematic review. Appl Sci (Basel) 2021; 11 (13) 5990
  • 300 Journal of Dental Education Volume 85 Supplement 1/June 2021. J Dent Educ 2021; 85: 871-876
  • 301 Aly MD. Effect of alkaline peroxide denture cleansers on surface roughness and hardness of conventional heat cured and CAD/CAM denture base resins. Egypt Dent J 2021; 67: 2431-2441
  • 302 Abou-Ayash S, Schimmel M, Özcan M, Ozcelik B, Brägger U, Yilmaz B. Trueness and marginal fit of implant-supported complete-arch fixed prosthesis frameworks made of high-performance polymers and titanium: an explorative in-vitro study. J Dent 2021; 113: 103784
  • 303 Piao XY, Shim JS, Park JM. Fabrication of metal-reinforced complete dentures using the CAD-CAM technique. Appl Sci (Basel) 2021; 11 (01) 7369
  • 304 Dawoud Y, Bahig D, Shawky AA. Evaluation of retention and assessment of biting force distribution of a complete denture fabricated Using 3D printed custom trays with Arcus Digma versus conventional method (a cross over study). Ain Shams Dent J 2021; 23: 120-130
  • 305 Dusmukhamedov S, Lee CN, Jeong SM, Choi BH. Digital denture fabrication: a technical note. Appl Sci (Basel) 2021; 11: 8093
  • 306 Comparison of patient satisfaction and chewing efficiency between conventional and 3D printed complete dentures. Mansoura J Dentist 2021; 8: 43-49
  • 307 Lam WYH, Mak KCK, Maghami E, Molinero-Mourelle P. Dental students' preference and perception on intraoral scanning and impression making. BMC Med Educ 2021; 21 (01) 501
  • 308 Hao K, Luo J, Di P, Zhang Y, Lin Y. Morphometry and displacement analysis of the upper lips following maxillary full-arch implant-supported fixed prostheses: a 3D morphometric study. BMC Oral Health 2021; 21 (01) 461
  • 309 Ragheb N, Ibrahim W. Biting force and chewing efficiency of conventional and CAD/CAM complete dentures. A cross-over study. Egypt Dent J 2021; 67: 3323-3335
  • 310 Zohny NA, Abdel-Ghany MM, Ashour AA. Effect of rapid prototyped upper complete denture on retention and patient satisfaction. Al-Azhar Dental J Girls 2021; 8: 577-582
  • 311 Tammam R. Comparison in vitro between three-dimensionally printed, milled Cad-Cam and manually fabricated interim crown materials. Al-Azhar Assiut Dent J 2021; 4: 141-150
  • 312 Jokstad A, Alkumru H. Immediate function on the day of surgery compared with a delayed implant loading process in the mandible: a randomized clinical trial over 5 years. Clin Oral Implants Res 2014; 25 (12) 1325-1335
  • 313 Marchini L. Patients' satisfaction with complete dentures: an update. Braz Dent Sci 2014; 17: 5-16
  • 314 Hasan MN, Islam SM. Bionic dentist is this the future of dentistry. Update Dent Coll J 2014; 3: 1-2
  • 315 Abduo J, Bennamoun M, Tennant M, McGeachie J. Effect of prosthodontic planning on lateral occlusion scheme: a comparison between conventional and digital planning. J Appl Oral Sci 2015; 23 (02) 196-205
  • 316 Park J-H, Cho I-H, Shin S-Y, Choi Y-S. The treatment of an edentulous patient with DENTCA™ CAD/CAM denture. Taehan Chikwa Pochol Hakhoe Chi 2015; 53: 19
  • 317 Abduo J, Lyons K, Bennamoun M. Trends in computer-aided manufacturing in prosthodontics: a review of the available streams. Int J Dent 2014; 2014: 783948
  • 318 Inoue Y, Hashioka M, Fujimori S. et al. Denture fabrication technique with a duplicate denture. J Acad Clin Dent 2015; 35: 203-210
  • 319 Kapri SC. Comparison of fiber reinforcement placed at different locations of pontic in interim fixed partial denture to prevent fracture: an in vitro study. J Indian Prosthodont Soc 2015; 15 (02) 142-147
  • 320 Vögtlin C, Schulz G, Jäger K, Müller B. Comparing the accuracy of master models based on digital intra-oral scanners with conventional plaster casts. Phys Med 2016; 1: 20-26
  • 321 Chen H, Wang H, Lv P, Wang Y, Sun Y. Quantitative evaluation of tissue surface adaption of CAD-designed and 3D printed wax pattern of maxillary complete denture. BioMed Res Int 2015; 2015: 453968
  • 322 Kim K, Noh K, Paek J, Kwon KR, Pae A. Prosthetic management of a growing patient with Russell-Silver syndrome: a clinical report. J Adv Prosthodont 2015; 7 (05) 406-410
  • 323 Romero L, Jiménez M, Espinosa MdelM, Domínguez M. New design for rapid prototyping of digital master casts for multiple dental implant restorations. PLoS One 2015; 10 (12) e0145253
  • 324 Abduo J. Morphological symmetry of maxillary anterior teeth before and after prosthodontic planning: comparison between conventional and digital diagnostic wax-ups. Med Princ Pract 2016; 25 (03) 276-281
  • 325 Grant GT, Campbell SD, Masri RM, Andersen MR. American College of Prosthodontists Digital Dentistry Glossary Development Task Force. Glossary of digital dental terms: American College of Prosthodontists. J Prosthodont 2016; 25 (Suppl. 02) S2-S9
  • 326 Jain S, Oberoi N, Kumar A, Aggarwal A, Kaur K. A study to evaluate the location and frequency of denture-related ulcerations and postinsertion adjustments in complete denture patients. Indian J Dent Sci 2017; 9: 16
  • 327 Han W, Li Y, Zhang Y. et al. Design and fabrication of complete dentures using CAD/CAM technology. Medicine (Baltimore) 2017; 96 (01) e5435
  • 328 The Glossary of Prosthodontic Terms: Ninth Edition. J Prosthet Dent 2017; 117 (5S): e1-e105
  • 329 Kwak Y-H, Lee S-H, Lee G-J, Kim H-J. Artificial teeth displacement of monolithic complete denture manufactured by 3D printer and milling machine. Taehan Chikwa Pochol Hakhoe Chi 2017; 55: 394
  • 330 Abduo J. Geometrical effects of conventional and digital prosthodontic planning wax-ups on lateral occlusal contact number, contact area, and steepness. J Oral Sci 2017; 59 (03) 431-438
  • 331 Eom D-Y, Leesungbok R, Lee S-W, Park S-J, Ahn S-J. CAD/CAM fabricated complete denture using 3D face scan: a case report. Taehan Chikwa Pochol Hakhoe Chi 2017; 55: 436
  • 332 Shinawi LA. Effect of denture cleaning on abrasion resistance and surface topography of polymerized CAD CAM acrylic resin denture base. Electron Physician 2017; 9 (05) 4281-4288
  • 333 Abdelnabi MH, Swelem AA. Digital technology in complete denture prosthodontics: a review of literature. Egypt Dent J 2017; 63: 2871-2885
  • 334 Kattadiyil MT, Jekki R, Goodacre CJ, Baba NZ. Comparison of treatment outcomes in digital and conventional complete removable dental prosthesis fabrications in a predoctoral setting. J Prosthet Dent 2015; 114 (06) 818-825
  • 335 Lin L, Fang Y, Liao Y, Chen G, Gao C, Zhu P. 3D printing and digital processing techniques in dentistry: a review of literature. Adv Eng Mater 2019; 21 (6) 1801013
  • 336 Joda T, Zarone F, Ferrari M. The complete digital workflow in fixed prosthodontics: a systematic review. BMC Oral Health 2017; 17 (01) 124
  • 337 Zupancic Cepic L, Gruber R, Eder J, Vaskovich T, Schmid-Schwap M, Kundi M. Digital versus conventional dentures: a prospective, randomized cross-over study on clinical efficiency and patient satisfaction. J Clin Med 2023; 12 (02) 434
  • 338 Ubale D, Uddanwadiker R. Latest trends in digital dentistry: a review. Int J Sci Res Sci Eng Technol 2018; 4 (08) 533-539
  • 339 Khurshid Z. Digital dentistry: transformation of oral health and dental education with technology. Eur J Dent 2023; 17 (04) 943-944
  • 340 Khurshid Z, Alqurashi H, Ashi H. Advancing environmental sustainability in dentistry and oral health. Eur J Gen Dent 2024; 13 (03) 263-268