J Wrist Surg
DOI: 10.1055/s-0044-1791956
Scientific Article

Median Nerve Displacement during Hardware Removal after Distal Radius Fractures

Hiroshi Ninomiya
1   Department of Orthopedic Surgery, Tachikawa General Hospital, Niigata, Japan
,
Makito Watanabe
1   Department of Orthopedic Surgery, Tachikawa General Hospital, Niigata, Japan
› Institutsangaben
Funding None declared.

Abstract

Background This retrospective study aimed to evaluate median nerve displacement observed during hardware removal procedures following volar plating for distal radius fractures.

Methods We reviewed all cases involving removal of distal radial volar locking plates at our institution by two surgeons from 2016 to 2021. Plating procedures and hardware removals were performed using the flexor carpi radialis (FCR) approach. We examined the position of the median nerve at the time of hardware removal.

Results Median nerve displacement to the radial side of the FCR occurred in 17 out of 67 cases (25%). There were no significant differences in the degree of fracture severity or involved surgeons between the normal position and displaced groups.

Conclusions The median nerve may be displaced radially from the FCR during hardware removal, and care should be taken to avoid causing iatrogenic nerve injury.

Level of Evidence Level II.

Ethical Approval

This study was approved by the Ethics Committee of Tachikawa General Hospital (approval no. 22–010, date of approval: July 19, 2022).


Informed Consent

There is no information (names, initials, hospital identification numbers or photographs) in the manuscript that can be used to identify patients.




Publikationsverlauf

Eingereicht: 07. Februar 2024

Angenommen: 19. September 2024

Artikel online veröffentlicht:
09. Dezember 2024

© 2024. Thieme. All rights reserved.

Thieme Medical Publishers, Inc.
333 Seventh Avenue, 18th Floor, New York, NY 10001, USA

 
  • References

  • 1 Court-Brown CM, Caesar B. Epidemiology of adult fractures: a review. Injury 2006; 37 (08) 691-697
  • 2 Koval KJ, Harrast JJ, Anglen JO, Weinstein JN. Fractures of the distal part of the radius. The evolution of practice over time. Where's the evidence?. J Bone Joint Surg Am 2008; 90 (09) 1855-1861
  • 3 Rozental TD, Blazar PE. Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius. J Hand Surg Am 2006; 31 (03) 359-365
  • 4 Drobetz H, Kutscha-Lissberg E. Osteosynthesis of distal radial fractures with a volar locking screw plate system. Int Orthop 2003; 27 (01) 1-6
  • 5 Lutsky KF, Beredjiklian PK, Hioe S, Bilello J, Kim N, Matzon JL. Incidence of hardware removal following volar plate fixation of distal radius fracture. J Hand Surg Am 2015; 40 (12) 2410-2415
  • 6 Snoddy MC, An TJ, Hooe BS, Kay HF, Lee DH, Pappas ND. Incidence and reasons for hardware removal following operative fixation of distal radius fractures. J Hand Surg Am 2015; 40 (03) 505-507
  • 7 Gyuricza C, Carlson MG, Weiland AJ, Wolfe SW, Hotchkiss RN, Daluiski A. Removal of locked volar plates after distal radius fractures. J Hand Surg Am 2011; 36 (06) 982-985
  • 8 Berdia S, Yu R. Volar approach to distal radius fractures. Oper Tech Orthop 2009; 19: 65-69
  • 9 Ilyas AM. Surgical approaches to the distal radius. Hand (N Y) 2011; 6 (01) 8-17
  • 10 Catalano III LW, Zlotolow DA, Hitchcock PB, Shah SN, Barron OA. Surgical exposures of the radius and ulna. J Am Acad Orthop Surg 2011; 19 (07) 430-438
  • 11 Conti Mica MA, Bindra R, Moran SL. Anatomic considerations when performing the modified Henry approach for exposure of distal radius fractures. J Orthop 2016; 14 (01) 104-107
  • 12 Soong M, Earp BE, Bishop G, Leung A, Blazar P. Volar locking plate implant prominence and flexor tendon rupture. J Bone Joint Surg Am 2011; 93 (04) 328-335
  • 13 McCann PA, Amirfeyz R, Wakeley C, Bhatia R. The volar anatomy of the distal radius: an MRI study of the FCR approach. Injury 2010; 41 (10) 1012-1014
  • 14 Henry AK. Extensile Exposure. 2nd ed.. Baltimore, MD: Williams and Wilkins; 1957: 67