Subscribe to RSS
DOI: 10.1055/s-0044-1792123
Ultrasound-Guided Thyroid Biopsy
Abstract
Thyroid nodules are prevalent, estimated to affect up to 68% of the population, and the incidence increases with age. With the advances in medical imaging utilization, the detection of incidental thyroid nodules continues to rise, and given the low rate of malignancy in incidentally discovered thyroid nodules (4–15%), diagnostic guidelines are imperative for their management. Several guidelines have been developed: the most commonly used guidelines in the United States include the American Thyroid Association (ATA) Guidelines and the American College of Radiology Thyroid Imaging Reporting Data System (TI-RADS). These guidelines call for the utilization of a biopsy of nodules depending on a sonographic morphologic categorization. This article aims to briefly review these two main guidelines and discuss the techniques for ultrasound-guided biopsy of thyroid nodules.
Keywords
thyroid nodules - ultrasound-guided biopsy - American Thyroid Association - TI-RADS - interventional radiologyPublication History
Article published online:
10 December 2024
© 2024. Thieme. All rights reserved.
Thieme Medical Publishers, Inc.
333 Seventh Avenue, 18th Floor, New York, NY 10001, USA
-
References
- 1 Barile A, Quarchioni S, Bruno F. et al. Interventional radiology of the thyroid gland: critical review and state of the art. Gland Surg 2018; 7 (02) 132-146
- 2 Yucel S, Balci IG, Tomak L. Diagnostic performance of thyroid nodule risk stratification systems: comparison of ACR-TIRADS, EU-TIRADS, K-TIRADS, and ATA Guidelines. Ultrasound Q 2023; 39 (04) 206-211
- 3 Abraham PJ, Lindeman BM. Management of incidental thyroid nodules. Surg Clin North Am 2024; 104 (04) 711-723
- 4 Alzahrani RA, Alghamdi AG. Diagnostic accuracy of fine-needle aspiration cytology (FNAC) in thyroid nodule excision cases. Cureus 2024; 16 (05) e60600
- 5 Tessler FN, Middleton WD, Grant EG. et al. ACR thyroid imaging, reporting and data system (TI-RADS): white paper of the ACR TI-RADS Committee. J Am Coll Radiol 2017; 14 (05) 587-595
- 6 Pang EH, Carter AW, Prisman E, Kreisman SH. Cost-effectiveness of the ACR TIRADS compared to the ATA 2015 risk stratification systems in the evaluation of incidental thyroid nodules. Acad Radiol 2024; S1076-6332 (24)00210-1
- 7 Ha EJ, Na DG, Baek JH, Sung JY, Kim JH, Kang SYUS. US fine-needle aspiration biopsy for thyroid malignancy: diagnostic performance of seven society guidelines applied to 2000 thyroid nodules. Radiology 2018; 287 (03) 893-900
- 8 Smith T, Kaufman CS. Ultrasound guided thyroid biopsy. Tech Vasc Interv Radiol 2021; 24 (03) 100768
- 9 Sencha AN, Patrunov YN, Pavlovich SV, Timofeyeva LA, Tukhbatullin MG, Smetnik AA. Current state of the problem of thyroid diseases: principles and technology of thyroid ultrasound. In: Sencha AN, Patrunov YN. eds. Thyroid Ultrasound. Springer International Publishing;; 2019: 1-38
- 10 Aribon PA, Teope E, Egwolf AL, Maningat MP. Diagnostic accuracy of American College of Radiology Thyroid Imaging Reporting Data System: a single-center cross-sectional study. J ASEAN Fed Endocr Soc 2024; 39 (01) 61-68
- 11 Torshizian A, Hashemi F, Khoshhal N. et al. Diagnostic performance of ACR TI-RADS and ATA guidelines in the prediction of thyroid malignancy: a prospective single tertiary center study and literature review. Diagnostics (Basel) 2023; 13 (18) 2972
- 12 Haugen BR, Alexander EK, Bible KC. et al. 2015 American Thyroid Association Management Guidelines for adult patients with thyroid nodules and differentiated thyroid cancer: the American Thyroid Association Guidelines Task Force on Thyroid Nodules and Differentiated Thyroid Cancer. Thyroid 2016; 26 (01) 1-133
- 13 Dietrich CF, Müller T, Bojunga J. et al. Statement and recommendations on interventional ultrasound as a thyroid diagnostic and treatment procedure. Ultrasound Med Biol 2018; 44 (01) 14-36
- 14 Seningen JL, Nassar A, Henry MR. Correlation of thyroid nodule fine-needle aspiration cytology with corresponding histology at Mayo Clinic, 2001-2007: an institutional experience of 1,945 cases. Diagn Cytopathol 2012; 40 (Suppl. 01) E27-E32
- 15 Cooper DS, Doherty GM, Haugen BR. et al; American Thyroid Association (ATA) Guidelines Taskforce on Thyroid Nodules and Differentiated Thyroid Cancer. Revised American Thyroid Association management guidelines for patients with thyroid nodules and differentiated thyroid cancer. Thyroid 2009; 19 (11) 1167-1214
- 16 Degirmenci B, Haktanir A, Albayrak R. et al. Sonographically guided fine-needle biopsy of thyroid nodules: the effects of nodule characteristics, sampling technique, and needle size on the adequacy of cytological material. Clin Radiol 2007; 62 (08) 798-803
- 17 Puga FM, Ferreira IP, Brandão JR, Fonseca L, Couto de Carvalho A, Freitas C. Comparison of cytological adequacy between 23- and 25-gauge in ultrasound-guided fine-needle aspiration of thyroid nodules: a single-center prospective study. Acta Cytol 2024; 68 (02) 121-127
- 18 Kelly NP, Lim JC, DeJong S, Harmath C, Dudiak C, Wojcik EM. Specimen adequacy and diagnostic specificity of ultrasound-guided fine needle aspirations of nonpalpable thyroid nodules. Diagn Cytopathol 2006; 34 (03) 188-190
- 19 Cohn S, Farhat R, El Khatib N. et al. Thyroid US-guided FNA techniques: a prospective, randomized controlled study. Am J Otolaryngol 2024; 45 (01) 104091
- 20 Guo YM, Huo JL, Qu R. et al. [A comparison of fine needle nonaspiration cytology versus fine needle aspiration for thyroid nodules: a meta-analysis]. Lin Chuang Er Bi Yan Hou Tou Jing Wai Ke Za Zhi 2018; 32 (11) 868-872
- 21 Maurya AK, Mehta A, Mani NS, Nijhawan VS, Batra R. Comparison of aspiration vs non-aspiration techniques in fine-needle cytology of thyroid lesions. J Cytol 2010; 27 (02) 51-54
- 22 Jiang D, Zang Y, Jiang D, Zhang X, Zhao C. Value of rapid on-site evaluation for ultrasound-guided thyroid fine needle aspiration. J Int Med Res 2019; 47 (02) 626-634
- 23 Zargham R, Johnson H, Anderson S, Ciolino A. Conditions associated with the need for additional needle passes in ultrasound-guided thyroid fine-needle aspiration with rapid on-site pathology evaluation. Diagn Cytopathol 2021; 49 (01) 105-108
- 24 Cengic I, Tureli D, Altas H, Ozden F, Bugdayci O, Aribal E. Effects of nodule characteristics on sampling number and duration of thyroid fine-needle aspiration biopsy: size does not matter, but cystic degeneration ratio does. Acta Radiol 2017; 58 (03) 286-291
- 25 Cappelli C, Pirola I, Agosti B. et al. Complications after fine-needle aspiration cytology: a retrospective study of 7449 consecutive thyroid nodules. Br J Oral Maxillofac Surg 2017; 55 (03) 266-269
- 26 Polyzos SA, Anastasilakis AD. Systematic review of cases reporting blood extravasation-related complications after thyroid fine-needle biopsy. J Otolaryngol Head Neck Surg 2010; 39 (05) 532-541
- 27 Kroft SH, Sever CE, Bagg A. et al. Laboratory workup of lymphoma in adults. Am J Clin Pathol 2021; 155 (01) 12-37
- 28 Dolidze DD, Covantsev S, Chechenin GM, Pichugina NV, Bedina AV, Bumbu A. Core needle biopsy for thyroid nodules assessment-a new horizon?. World J Clin Oncol 2024; 15 (05) 580-586
- 29 Vander Poorten V, Goedseels N, Triantafyllou A. et al. Effectiveness of core needle biopsy in the diagnosis of thyroid lymphoma and anaplastic thyroid carcinoma: a systematic review and meta-analysis. Front Endocrinol (Lausanne) 2022; 13: 971249
- 30 Khoo TK, Baker CH, Hallanger-Johnson J. et al. Comparison of ultrasound-guided fine-needle aspiration biopsy with core-needle biopsy in the evaluation of thyroid nodules. Endocr Pract 2008; 14 (04) 426-431
- 31 Chen BT, Jain AB, Dagis A. et al. Comparison of the efficacy and safety of ultrasound-guided core needle biopsy versus fine-needle aspiration for evaluating thyroid nodules. Endocr Pract 2015; 21 (02) 128-135
- 32 Ha EJ, Suh CH, Baek JH. Complications following ultrasound-guided core needle biopsy of thyroid nodules: a systematic review and meta-analysis. Eur Radiol 2018; 28 (09) 3848-3860
- 33 Khadra H, Kholmatov R, Monlezun D, Kandil E. Do anticoagulation medications increase the risk of haematoma in ultrasound-guided fine needle aspiration of thyroid lesions?. Cytopathology 2018; 29 (06) 565-568