Abstract
Endovascular aortic repair has transformed the treatment of aortic pathologies, providing minimally invasive alternatives to traditional open surgery. Despite these advancements, endovascular procedures continue to encounter substantial challenges, including navigating tortuous and calcified vessels, precise catheterization of the aortic branch vessels in complex cases, and the significant risks of radiation exposure to both patients and operators. Recent innovations in electromagnetic (EM) tracking and 3D imaging offer a promising alternative to traditional methods. This review focuses on the Intraoperative Positioning System (IOPS), a novel EM-based image guidance system developed by Centerline Biomedical, Inc. (Cleveland, OH). IOPS uses sensorized, EM-tracked devices to enhance procedural precision and safety by minimizing reliance on ionizing radiation while improving visualization and the accuracy of catheterization in vascular anatomies. This technology enables parts of the procedure to be performed without the need for ionizing radiation, offering a safer and more efficient approach to endovascular procedures.
Disclosure
B.S.F. serves on the scientific advisory board for Centerline Biomedical, Inc. (Cleveland, Ohio).
Publikationsverlauf
Artikel online veröffentlicht:
18. Dezember 2024
© 2024. Thieme. All rights reserved.
Thieme Medical Publishers, Inc.
333 Seventh Avenue, 18th Floor, New York, NY 10001, USA
-
References
- 1 Eagleton MJ. Updates in endovascular procedural navigation. Can J Cardiol 2022; 38 (05) 662-671
- 2 van Herwaarden JA, Jansen MM, Vonken EPA. et al. First in human clinical feasibility study of endovascular navigation with Fiber Optic RealShape (FORS) technology. Eur J Vasc Endovasc Surg 2021; 61 (02) 317-325
- 3 Andria G, Attivissimo F, Di Nisio A, Lanzolla AML, Ragolia MA. Assessment of position repeatability error in an electromagnetic tracking system for surgical navigation. Sensors (Basel) 2020; 20 (04) 961
- 4 Franz AM, Haidegger T, Birkfellner W, Cleary K, Peters TM, Maier-Hein L. Electromagnetic tracking in medicine – a review of technology, validation, and applications. IEEE Trans Med Imaging 2014; 33 (08) 1702-1725
- 5 Rajagopal M, Venkatesan AM. Image fusion and navigation platforms for percutaneous image-guided interventions. Abdom Radiol (NY) 2016; 41 (04) 620-628
- 6 Braga D, Ducaud C, Camardo A, Hofacker H, Goel V, Beasley R. Nonfluoroscopic 3D image guidance system reduces navigation times through five 3D-printed iliofemoral vascular phantoms. J Endovasc Ther 2023;
- 7 Cochennec F, Riga C, Hamady M, Cheshire N, Bicknell C. Improved catheter navigation with 3D electromagnetic guidance. J Endovasc Ther 2013; 20 (01) 39-47
- 8 de Lambert A, Esneault S, Lucas A, Haigron P, Cinquin P, Magne JL. Electromagnetic tracking for registration and navigation in endovascular aneurysm repair: a phantom study. Eur J Vasc Endovasc Surg 2012; 43 (06) 684-689
- 9 Tystad Lund K, Tangen GA, Manstad-Hulaas F. Electromagnetic navigation versus fluoroscopy in aortic endovascular procedures: a phantom study. Int J Comput Assist Radiol Surg 2017; 12 (01) 51-57
- 10 West K, Al-Nimer S, Goel VR. et al. Three-dimensional holographic guidance, navigation, and control (3D-GNC) for endograft positioning in porcine aorta: feasibility comparison with 2-dimensional X-ray fluoroscopy. J Endovasc Ther 2021; 28 (05) 796-803
- 11 Moncharmont L, Moreau-Gaudry A, Medici M, Bricault I. Phantom evaluation of a navigation system for out-of-plane CT-guided puncture. Diagn Interv Imaging 2015; 96 (06) 531-536
- 12 Schwein A, Kramer B, Chinnadurai P. et al. Flexible robotics with electromagnetic tracking improves safety and efficiency during in vitro endovascular navigation. J Vasc Surg 2017; 65 (02) 530-537
- 13 Sieren MM, Jäckle S, Eixmann T. et al. Radiation-free thoracic endovascular aneurysm repair with fiberoptic and electromagnetic guidance: a phantom study. J Vasc Interv Radiol 2022; 33 (04) 384-391.e7
- 14 Jaeger HA, Nardelli P, O'Shea C. et al. Automated catheter navigation with electromagnetic image guidance. IEEE Trans Biomed Eng 2017; 64 (08) 1972-1979
- 15 Hatt CR, Jain AK, Parthasarathy V, Lang A, Raval AN. MRI-3D ultrasound-X-ray image fusion with electromagnetic tracking for transendocardial therapeutic injections: in-vitro validation and in-vivo feasibility. Comput Med Imaging Graph 2013; 37 (02) 162-173
- 16 Bruners P, Penzkofer T, Nagel M. et al. Electromagnetic tracking for CT-guided spine interventions: phantom, ex-vivo and in-vivo results. Eur Radiol 2009; 19 (04) 990-994
- 17 Centerline Biomedical Completes First Human Patient in the United States with IOPS™ (Intra-Operative Positioning System). PR Newswire; 2020. Accessed November 26, 2024 at: https://www.prnewswire.com/news-releases/centerline-biomedical-completes-first-human-patient-in-the-united-states-with-iops-intra-operative-positioning-system-301051842.html
- 18 Farivar BS. Real-time superior mesenteric artery catheterization in 3D without ionizing radiation. J Vasc Surg 2023; 77 (03) 939-940
- 19 Le Q, Farivar BS. Endovascular Left Common Iliac Aneurysm Repair Using Intraoperative Positioning System Technology for 3D Device Guidance. presented at: Southern Association for Vascular Surgery 47th Annual Meeting; 2023; Rio Grande, Puerto Rico. Accessed November 26, 2024 at: https://meeting.savs.org/Program/2023/V3.cgi
- 20 Farivar BS. 3D aortic dissection luminal navigation: a radiation free alternative or complement to intravascular ultrasound?. Eur J Vasc Endovasc Surg 2024; S1078 -5884(24)00813-X
- 21 Muluk SC, Elrakhawy M, Chess B, Rosales C, Goel V. Successful endovascular treatment of severe chronic mesenteric ischemia facilitated by intraoperative positioning system image guidance. J Vasc Surg Cases Innov Tech 2021; 8 (01) 60-65
- 22 Hanif H, Khan A, Clark RM, Marek J, Rana MA. Endovascular repair of bilateral common iliac artery aneurysms using intraoperative positioning system. J Vasc Surg Cases Innov Tech 2024; 10 (05) 101521