Endoscopy 1999; 31(7): 541-545
DOI: 10.1055/s-1999-58
Original Article
Georg Thieme Verlag Stuttgart ·New York

Surface-Rendering Imaging of Gastrointestinal Lesions by Three-Dimensional Endoscopic Ultrasonography

J. Yoshino, S. Nakazawa, K. Inui, Y. Katoh, T. Wakabayshi, T. Okushima, T. Kobayashi, S. Watanabe
  • Dept. of Internal Medicine, Second Hospital, Fujita Health University, School of Medicine, Nagoya, Japan
Further Information

Publication History

Publication Date:
31 December 1999 (online)

Background and Study Aims: In three-dimensional endoscopic ultrasonography (3D-EUS), a surface-rendering method can provide both a surface image and a cross-sectional ultrasonographic image. We evaluated the usefulness of this imaging method for digestive tract lesions.

Patients and Methods: A total of 30 patients underwent 3D-EUS with surface-rendering using a 3D probe system which arranged individual radial scanning images into 128 points on a computer monitor to outline the surface of a lesion. A complete surface image of the lesion was displayed on the computer monitor using lines obtained from 40 radial scanning images.

Results: Surface-rendering images of lesions were similar to endoscopic images. The surface-rendering method permitted precise correlation of two-dimensional images depicting a slice of a lesion with the corresponding surface of the lesion. Unlike conventional endoscopy, this approach permitted observations of lesions at any desired angle. Complete images of lesions were achieved in 14 patients and were half-completed in another five, but could not be obtained in 11 patients: in six the distance between the lesion and the 3D probe was too short to avoid artifacts, while in five the lesion was larger than the longitudinal scanning length of 4 cm or greater than 90 ° in extent in radial scanning images. Artifacts caused by heartbeat led to irregular images in four patients, including three with esophageal cancer and one with gastric cancer.

Conclusions: Despite some problems, surface-rendering imaging should prove useful for diagnosis, and the method will improve as software is perfected.

References

  • 1 Raya S P. Low-level segmentation of 3D magnetic resonance brain images: a rule-based system.  IEEE Trans Med Imaging. 1990;  9 327-337
  • 2 Rosenfield K, Boffetti P, Kaufman J, et al. Three-dimensional reconstruction of human carotid arteries from images obtained during noninvasive B-mode ultrasound examination.  Am J Cardiol. 1992;  70 379-384
  • 3 Cavaye D, White R, Kopchok G, et al. Intravascular ultrasound imaging: the new standard for guidance and assessment of endovascular interventions?.  J Clin Laser Med Surg. 1992;  10 349-353
  • 4 Zeman P, Fox S, Silverman P, et al. Helical (spiral) CT of the abdomen.  Am J Roentgenol. 1993;  160 719-725
  • 5 Hamper U M, Trapanotto V, Sheth S, et al. Three-dimensional US: preliminary clinical experience.  Radiology. 1994;  191 397-401
  • 6 Pretorius D H, Nelson T R. Fecal face visualization using three-dimensional ultrasonography.  J Ultrasound Med. 1995;  14 349-356
  • 7 Nakazawa S, Yoshino J, Nakamura T, et al. Endoscopic ultrasonography of gastric myogenic tumor - a comparative study between histology and ultrasonography.  J Ultrasound Med. 1989;  8 353-357
  • 8 Ohashi S, Nakazawa S, Yoshino J. Endoscopic ultrasonography in the assessment of invasive gastric cancer.  Scand J Gastroenterol. 1989;  24 1039-1048
  • 9 Niwa Y, Nakazawa S, Yoshino J, et al. Quantification of gastric ulcer healing by endoscopic ultrasonography.  Gastrointest Endosc. 1990;  36 116-122
  • 10 Hashimoto H, Yokoyama S, Nakao K, et al. The capability of three dimensional display during endoscopic ultrasonography.  Dig Endosc. 1991;  3 194-198
  • 11 Mueller M O, Stamos M J, Cavaya D M, et al. Three-dimensional transrectal ultrasound: preliminary patient evaluation.  Laparoendosc Surg. 1992;  2 223-227
  • 12 Hunerbein M, Below C, Schlag P M. Three-dimensional endorectal ultrasonography for staging of obstructing rectal cancer.  Dis Colon Rectum. 1996;  39 636-642
  • 13 Kallimanis G, Garra B S, Tio T L, et al. The feasibility of three-dimensional endoscopic ultrasonography: a preliminary report.  Gastrointest Endosc. 1995;  41 235-239
  • 14 Nishimura K, Niwa Y, Goto H, et al. Three-dimensional endoscopic ultrasonography of gastrointestinal lesions using an ultrasound probe.  Scand J Gastroenterol. 1997;  32 862-868
  • 15 Kanemaki N, Nakazawa S, Inui K, et al. Three-dimensional ultrasonography: preliminary results of a new technique for the diagnosis of diseases of pancreatobiliary system.  Endoscopy. 1997;  29 726-731
  • 16 Harada K, Nakazawa S, Yoshino J, et al. A study of volume measurement for digestive tract tumors by three-dimensional ultrasound system.  Gastroenterol Endosc. 1997;  39 1210-1218
  • 17 Yoshino J, Nakazawa S, Wakabayashi T. Three-dimensional endoscopic ultrasonography: a new diagnostic method. In: Nakazawa S (ed). Future trends in gastroenterology.  Tokyo; Life Science Publishing 1998: 33-36

J. YoshinoM.D. 

Dept. of Internal Medicine

Fujita Health University

School of Medicine

3-6-10 Otobashi

Nakagawa-ku

Nagoya 454-8509

Japan

Phone: + 81-52-3239886

Email: jyoshino@fujita-hu.ac.jp