Subscribe to RSS
DOI: 10.1055/s-2001-12416
J.A.Barth Verlag in Medizinverlage Heidelberg GmbH & Co.KG
Ergebnisse mit der endovaskulären Ausschaltung abdomineller Bauchaortenaneurysmen
Results of endovascular treatment of abdominal aortic aneurysmsPublication History
Publication Date:
31 December 2001 (online)
Results of endovascular treatment of abdominal aortic aneurysms
Summary
According to the principles of minimal invasive surgery a reduced operative trauma and complication rate are the main goals of endovascular aneurysm exclusion. From July 1996 to August 1999 we found 75 patients eligible for endovascular aneurysm therapy. The procedure was primarily successful in 95 % of the patients. In the first time we had to switch to open surgery in 4 patients. There was 1 procedure related death. Most frequent later complications were graft occlusion (9.7 %) and type I, II and III leakages (14.1 %), which were partially repaired using endovascular techniques and partially by use of open surgery. In a selected group of patients the middle term results of infrarenal aneurysm therapy by endovascular stent graft implantation are promising.
Zusammenfassung
Ziel der endovaskulären Aneurysmaausschaltung soll nach den Prinzipien der minimal-invasiven Chirurgie ein reduziertes Operationstrauma und somit eine verminderte Komplikationsrate sein. Von Juni 1996 bis August 1999 wurde bei 75 Patienten die Indikation zur endovaskulären Aneurysmaausschaltung gestellt. Bei 95 % der Patienten war das Verfahren primär erfolgreich. Initial mußte viermal auf eine konventionelle Operation umgestiegen werden. Es war ein verfahrensbedingter Todesfall zu verzeichnen. Als wesentliche Komplikationen traten im weiteren Verlauf Prothesenschenkelverschlüsse (9,7 %) und Leckagen vom Typ I, II, und III (14,1 %) auf, die teils endovaskulär teils operativ versorgt wurden. Bei einem selektionierten Patientengut hat die Therapie infrarenaler Aortenaneurysmen mit einer endovaskulären Stent-Graft-Implantation mittelfristig erfolgversprechende Ergebnisse erbracht.
Key words
Endovascular graft - abdominal aortic aneurysm - complications
Schlüsselwörter
Endovaskuläre Prothese - Bauchaortenaneurysma - Komplikationen
Literatur
- 1 Ahn S S, Rutherford R B, Johnstone K W. et al . Reporting standards for infrarenal endovascular abdominal aortic aneurysm repair. J Vasc Surg. 1997; 25 405-410
- 2 Alimi Y, Chafke N, Rivoal E. Rupture of an abdominal aortic aneurysm after endovascular graft placement and aneurysm size reduction. J Vasc Surg. 1998; 28 178-183
- 3 Allenberg J R, Schumacher H, Robbie P. Computergesteuerte Evaluation der Aortenaneurysma-Morphologie zur Wahl des Therapieverfahrens. Langenbecks. Arch Chir. 1998; 115 105
- 4 Amesur N B, Zaijko A B, Makaroun M S. Treatment of failed bifurcated abdominal aortic stent-graft with thrombolysis and Wallstent placement. J Vasc Intervent Radiol. 1997; 8 795-798
- 5 Blum U, Voshage G, Lammer J. Endoluminal stentgrafts for infrarenal abdominal aortic aneurysms. N EngI J Med. 1997; 336 13-20
- 6 Brewster D C, Geller S C, Kaufmann J A. et al . Initial experience with endovascular aneurysm repair: comparison of early results with outcome of conventional open repair. J Vasc Surg. 1998; 27 992-1005
- 7 Broeders J, Blankensteijn J D, Gvakharia A. et al . The efficacy of transfemoral endovascular aneurysm management a study on size changes of the abdominal aorta during mid-term follow-up. Eur J Vasc Endovasc Surg. 1997; 14 84-90
- 8 Bürger Th, Heucke A, Hallaoul Z. et al . Interleukinmuster, Procalcitoninspiegel und zellulärer Immunstatus nach endovaskulärer Aneurysmachirurgie. Zentralbl Chir. 2000; 125 15-21
- 9 Buth J, Leheij R J. Early complications an endoleaks after endovascular abdominal aortic aneurysm repair: Report of a multicenter study. J Vasc Surg. 2000; 31 134-136
- 10 Chuter T A M, Wendt G, Hopkinson B R. et al . Bifurcated stent-graft for abdominal aortic aneurysm. Cardiovasc Surg. 1997; 5 388-392
- 11 Clement D, Ozsvath K, Chang B. et al . The incidence, natural history and outcome of secondary intervention for persistent collateral flow in the excluded abdominal aortic aneurysm. J Vasc Surg. 1999; 30 968-976
- 12 Cuypers P, Nevelsteen A, Buth J. et al . Complications in the endovascular repair of abdominal aortic aneurysms: a risk factor analysis. Eur J Vasc Endovasc Surg. 1999; 18 245-252
- 13 Cuypers P, Buth J, Harris P L. et al . Realistic expectations for patients with stent-graft treatment of abdominal aortic aneurysms. Results of a European multicenter registry. Eur J Vasc Endovasc Surg. 1999; 17 507-516
- 14 Harris P L. The highs and lows of endovascular aneurysm repair: the first two years of the Eurostar Registry. Ann R Coll Surg Engl. 1999; 81 161-165
- 15 Harris P, Brennan J, Martin J. et al . Longitudinal aneurysm shrinkage following endovascular aortic aneurysm repair: a source of intermediate and late complications. J Endovasc Surg. 1999; 6 11
-
16 Imig H. Bauchaortenaneurysma (Leitlinien zu Diagnostik und Therapie der Aneurysmen der infrarenalen Aorta abdominalis). In: Vorstand der Deutschen Gesellschaft für Gefäßchirurgie (Hrsg). Leitlinien zu Diagnostik und Therapie in der Gefäßchirurgie. Deutscher Ärzte-Verlag, Köln 1998; 81-87
- 17 Katz D J, Szanley J C, Zelendock G B. Operative mortality rates for intact and ruptured abdominal aortic aneurysms in Michigan: An eleven-year state wide experience. J Vasc Surg. 1994; 19 804-817
- 18 Malina M, Ivancev K, Chuter T A M. et al . Changing aneurysmal morphology after endovascular grafting: relation to leakage or persistent perfusion. J Endovasc Surg. 1997; 4 23-33
- 19 Matsumura J S, Pearce W H, McCarthy W J. et al . Reduction in aortic aneurysm size: early results after endovascular graft placement. J Vasc Surg. 1997; 25 113-123
- 20 May J, White G H, Waugh R. et al . Adverse events after endoluminal repair of abdominal aortic aneurysms: a comparison during two successive periods of time. J Vasc Surg. 1999; 29 32-39
- 21 May J, White G H, Yu W. et al . A prospective study of anatomicopathological changes in abdominal aortic aneurysms following endoluminal repair: Is the aneurysmal process reversed. J Vasc Endovasc Surg. 1996; 12 11-17
- 22 May J, White G H, Yu W. et al . Concurrent comparison of endoluminal versus open repair in the treatment of abdominal aortic aneurysms: analysis of 303 patients by life table method. J Vasc Surg. 1998; 27 213-221
- 23 Miahle C, Amicabile A, Becquemin J P. Endovascular treatment of infrarenal abdominal aortic aneurysms by the Stentor system: preliminary results of 79 cases. J Vasc Surg. 1997; 26 199-209
- 24 Nasim A, Thompson M M, Sayers R D. et al . Is endoluminal abdominal aortic aneurysm repair using an aortoaortic device a durable procedure. Eur J Vasc Endovasc Surg. 1998; 12 522-528
- 25 Parodi J C, Palmaz J C, Barone H D. Transfemoral intraluminal graft implantation for abdominal aortic aneurysms. Ann Vasc Surg. 1990; 5 491-499
- 26 Parodi J C, Barone A, Piraino R. et al . Endovascular treatment of abdominal aortic aneurysms: lessons learned. J Endovasc Surg. 1997; 4 102-110
- 27 Riepe G, Heilberger P, Umscheid T. Frame dislocation of body middle rings in endovascular stent tube grafts. Eur J Endovasc Surg. 1998; 17 28-34
- 28 Riepe G, Loos J, Imig H. Long-term in vivo alterations of polyester vascular grafts in humans. Eur J Vasc Endovasc Surg. 1997; 13 540-548
- 29 Riepe G, Heintz C, Chakfé N. et al . Stentdrahtbrüche und Maschenlockerungen explantierter, endovaskulärer Prothesen. Zentralbl Chir. 2000; 125 22-26
- 30 Rückert I, Romaniuk P, Rogalla P. et al . Combined surgical an endovascular removal of thrombus entirely occluding a bifurcated aortic stent-graft. J Endovasc Surg. 1998; 5 323-328
- 31 Rückert I, Romaniuk P, Rogalla P, Umscheid T, Stelter W J, Müller J M. A method for adjusting a malpositioned bifurcated aortic graft. J Endovasc Surg. 1998; 5 261-265
- 32 Sanchez L A, Faries P L, Marin M L. et al . Chronic intraaneurysmal pressure measurement: an experimental method for evaluating the effectiveness of endovascular aortic aneurysm exclusion. J Vasc Surg. 1997; 26 222-230
- 33 Sandison A J P, Edmonson R A, Panayiotopoulos Y P. et al . Fatal colon ischaemia after stent-graft for aortic aneurysm. Eur J Vasc Endovasc Surg. 1997; 13 219-220
- 34 Schumacher H, Eckstein H H, Kallinowski F, Allenberg J R. Morphometry and classification in abdominal aortic aneurysms: patient selection for endovascular and open surgery. J Endovasc Surg. 1997; 4 39
- 35 Schumacher H, Richter G M, Eckstein H H, Allenberg J R. Endovasculäre infrarenale Aortenaneurysmachirurgie selektionierter Patienten: 3-Jahresergebnis und Komplikationsmanagement. Langenbecks Arch Chir. 1998; 115 1230
- 36 Schumacher H, Eckstein H H, Allenberg J R. Gefäßendoprothetik, aktueller Stand und Perspektiven einer neuen Technologie. Chirurg. 1999; 70 858-867
- 37 Sonesson B, Resch T, Länne T, Ivancev K. The fate of the infrarenal aortic neck after open aneurysm surgery. J Vasc Surg. 1998; 28 889-894
- 38 Stelter W, Umscheid T, Ziegler P. Three-year experience with modular stent-graft devices for endovascular AAA treatment. J Endovasc Surg. 1997; 4 362-369
- 39 Swartbol P, Norgren L, Albrechtsson U. et al . Biological responses differ considerably between endovascular and conventional aortic aneurysm surgery. Eur J Vasc Endovasc Surg. 1996; 12 18-25
- 40 Swartbol P, Truedsson L, Norgren L. Adverse reactions during endovascular treatment of aortic aneurysms may be triggered by interleukin 6 release from the thrombotic content. J Vasc Surg. 1998; 28 664-668
- 41 Syk I, Brunkwall J, Ivancev K. et al . Postoperative fever, bowel ischemia and cytokine response to abdominal aortic aneurysm repair - a comparison between endovascular and open surgery. Eur J Vasc Endovasc Surg. 1998; 15 398-405
- 42 Thompson M M, Smith J, Naylor A R. et al . Ultrasound-based quantification of emboli during conventional and endovascular aneurysm repair. J Endovasc Surg. 1997; 4 33-38
- 43 Torsello G B, Klenk E, Kasprzak B, Umscheid T. Rupture of abdominal aortic aneurysm previously treated by endovascular stentgraft. J Vasc Surg. 1998; 28 184-187
- 44 Umscheid Th, Stelter W J. Time-related alterations in shape, position, and structure of self-expanding, modular aortic stent-grafts: A 4-year single-center follow-up. J Endovasc Surg. 1999; 6 17-32
-
45 Umscheid Th, Stelter W J, Ziegler P. Spätere Reparaturen - sind sie unvermeidlich. In: Metz L, Stelter W (Hrsg). Endovaskuläre Techniken zur Carotis- und Aortenaneurysma-Chirurgie. Steinkopff, Darmstadt 1998; 187-193
- 46 Umscheid Th, Stelter W J, Ziegler P. Mittelfristige Komplikationen und Probleme nach endovaskulären Aortenstentprothesen. Zentralbl Chir. 2000; 125 7-14
- 47 Walker S R, Halliady K, Husuf S W. et al . A study on the patency of the inferior mesenteric and lumbar arteries in the incidence of endoleak following endovascular repair of infrarenal aortic aneurysms. Clin Radiol. 1998; 53 593-595
- 48 Walker S R, Macierewicz J, Elmarasy N M. et al . A prospective study to assess changes in proximal aortic neck dimensions after endovascular repair of abdominal aortic aneurysms. J Vasc Surg. 1999; 29 625-630
- 49 White G H, May J, Waugh R C, Chaufour C, Yu W. Type III and type IV endoleak: toward a complete definition of blood flow in the sac after endoluminal AAA repair. J Endovasc Surg. 1998; 5 305
- 50 White G H, Yu W, May J. “Endoleak”: a proposed new terminology to describe incomplete aneurysm exclusion by an endovascular graft. J Endovasc Surg. 1996; 3 124-125
- 51 White G H, Yu W, May J. Endoleak as a complication of endoluminal grafting of abdominal aortic aneurysms: classification, incidence, diagnosis, and management. J Endovasc Surg. 1997; 4 152-158
- 52 White G H, Yu W, May J. Three-year experience with the White-Yu Endovascular-GAD graft for transluminal repair of aortic and iliac aneurysms. J Endovasc Surg. 1997; 4 124-136
- 53 Yusuf W J, Whitaker S C, Chuter T A M. et al . Early results of endovascular aortic aneurysm surgery with aortouniiliac graft, contralateral iliac occlusion, and femorofemoral bypass. J Vasc Surg. 1997; 25 165-172
- 54 Zarins C K, White R A, Schwarten D. et al . AneuRx stent graft versus open surgical repair of aortic aneuysms: Multicenter prospective clinical trial. J Vasc Surg. 1999; 29 292-308
Dr. Klaus Balzer
Gefäßchirurgische Klinik
Evangelisches Krankenhaus
Wertgasse 30
D-45468 Mülheim/Ruhr