Rofo 2002; 174(1): 29-32
DOI: 10.1055/s-2002-19551
Rapid Communication
Originalarbeit
© Georg Thieme Verlag Stuttgart · New York

T1-weighted MR-lymphography after intramammary administration of Gadomer-17 in pigs

T1-gewichtete MR-Lymphographie nach intramammärer Injektion von
Gadomer-17 in Mausschweine
G.  Staatz1 , E.  Spüntrup1 , A.  Buecker1 , B.  Misselwitz2 , R.  W.  Günther1
  • 1Dept. of Diagnostic Radiology, Aachen University of Technology
  • 2Schering AG, Imaging Technologies and Preclinical Contrast Media Research, MRI, Berlin
Weitere Informationen

Publikationsverlauf

Publikationsdatum:
29. April 2004 (online)

Abstract

Purpose: To evaluate the enhancement of regional lymph nodes and lymphatic vessels after intramammary injection of Gadomer-17. Materials and Methods: T1-weighted MR-lymphography was performed in 8 domestic pigs after intramammary injection of 5 - 10 µmol/kg bodyweight (bw) Gadomer-17 on a 1.5 T-MR scanner. T1-weighted 3D gradient-echo images were acquired 10 to 120 minutes after contrast material injection in coronal and sagittal planes. The contrast enhancement of the draining lymphatic system was qualitatively assessed by two radiologists applying a three grade scale. Results: T1-Weighted MR-lymphography after intramammary injection of Gadomer-17 was feasible in each pig. A dose of 5 µmol/kg body weight Gadomer-17 was best suited for MR-lymphography of the mammary line and the draining lymphatic system. Enhancement of regional lymph nodes and lymphatic vessels was classified as good in 5, and excellent in three cases. Conclusions: Intramammary injection of Gadomer-17 allows for good quality T1-weighted MR-lymphography of mammary gland draining regional lymph nodes and lymphatic vessels. This new technique might offer potential for the evaluation of the sentinel lymph node in patients with breast cancer.

Zusammenfassung

Ziel: Untersuchung der Kontrastmittelanreicherung lokoregionärer Lymphknoten und Lymphbahnen nach intramammärer Injektion von Gadomer-17. Material und Methoden: Die T1-gewichtete MR-Lymphographie wurde bei 8 Hausschweinen nach intramammärer Injektion von 5 - 10 µmol/kg Körpergewicht (KG) Gadomer-17 in einem 1,5 Tesla MR-Gerät durchgeführt. Dabei wurden T1-gewichtete 3D Gradientenechosequenzen 10 - 120 Minuten nach Kontrastmittelapplikation in koronarer und sagittaler Schnittführung akquiriert. Die Kontrastmittelanreicherung des die Milchleiste drainierenden lymphatischen Systems wurde qualitativ durch zwei Radiologen im Consensus mittels einer Dreipunkteskala bewertet. Ergebnisse: Die T1-gewichtete MR-Lymphographie nach intramammärer Injektion von Gadomer-17 ließ sich bei allen Versuchstieren erfolgreich durchführen. Eine Dosis von 5 µmol/kg KG war für die lymphographische Darstellung der Milchleiste und der abführenden Lymphwege am besten geeignet. Die Kontrastmittelanreicherung des lokoregionären Lymphsystems der Mamma wurde bei 5 Versuchstieren mit gut und bei drei Versuchstieren mit sehr gut bewertet. Schlussfolgerung: Die intramammäre Injektion von Gadomer-17 ermöglicht eine qualitativ gute MR-Lymphographie des lokoregionären lymphatischen Systems der Mamma. Eine Nutzung dieser neuen MR-Technik zur Bestimmung des Wächterlymphknotens bei Patienten mit Brustkrebs ist vorstellbar.

Literatur

  • 1 Staatz G, Nolte-Ernsting C CA, Adam G B, Grosskortenhaus S, Misselwitz B, Bücker A, Günther R W. Interstitial T1-weighted MR-lymphography: lipophilic, perfluorinated gadolinium-chelates in pigs.  Radiology. 2001;  220 129-134
  • 2 Ruehm S G, Corot C, Debatin J F. Interstitial MR lymphography with a conventional extracellular gadolinium-based agent: assessment in rabbits.  Radiology. 2001;  218 664-669
  • 3 Ruehm S G, Schroeder T, Debatin J F. Interstitial MR lymphography with gadoterate meglumine: initial experience in humans.  Radiology. 2001;  220 816-821
  • 4 Staatz G, Nolte-Ernsting C CA, Bücker A, Misselwitz B, Großkortenhaus S, Pflüger D, Günther R W. Interstitielle T1-gewichtete MR-Lymphographie mit dem polymeren Kontrastmittel Gadomer-17 im Tierexperiment.  Fortschr Röntgenstr. 2001;  173 1131-1136
  • 5 Misselwitz B, Schmitt-Willich H, Ebert W, Frenzel T, Weinmann H. Pharmacokinetics of Gadomer-17, a new dendritic magnetic resonance contrast agent.  MAGMA. 2001;  12 128-134
  • 6 Nickel R, Schummer A, Seiferle E. Lymphknoten und Lymphsammelgänge des Schweines. In: Lehrbuch der Anatomie der Haustiere. Berlin, Hamburg; Paul Parey Verlag 1984: 376-395
  • 7 Ivens D, Hoe A L, Podd T J, Hamilton C R, Taylor I, Royle G T. Assessment of arm morbidity from complete axillary dissection.  Br J Cancer. 1992;  66 136-138
  • 8 Cady B, Stone M D, Schuler J G, Thakur R, Wanner M A, Lavin P T. The new era in breast cancer: invasion, size, and nodal involvement dramatically decreasing as a result of mammographic screening.  Arch Surg. 1996;  131 301-308
  • 9 Morton D L, Wen D R, Wong J H, Economou J S, Cagle L A, Kristian Storm F, Foshag L J, Cochran A J. Technical details of intraoperative lymphatic mapping for early staging melanoma.  Arch Surg. 1992;  127 392-399
  • 10 Krag D, Weaver D, Alex J C, Fairbank J T. Surgical resection and radiolocalization of the sentinel lymph node in breast cancer using a gamma probe.  Surg Oncol. 1993;  2 335-340
  • 11 Hsueh E C, Turner R R, Giuliano A E. Lymphoscintigraphy and lymphatic mapping for sentinel lymph nodes.  World J Surg. 2001;  25 794-797
  • 12 Uren R F, Howman-Giles R, Renwick S B, Gillet D. Lymphatic mapping of the breast: locating the sentinel lymph nodes.  World J Surg. 2001;  25 789-793
  • 13 Birdwell R L, Smith K L, Betts B J, Ikeda D M, Strauss H W, Jeffrey S S. Breast cancer: variables affecting sentinel lymph node visualization at preoperative lymphoscintigraphy.  Radiology. 2001;  220 47-53
  • 14 Mariani G, Moresco L, viale G, Villa G, Bagnasco M, Canavese G, Buscombe J, Strauss H W, Paganelli G. Radioguided sentinel lymph nodde biopsy in breast cancer surgery.  J Nucl Med. 2001;  42 1198-1215
  • 15 Giuliano A E, Haigh P I, Brennan M B, Hansen N M, Kelley M C, Ye Y, Glass E C, Turner R R. Prospective observational study of sentinel lymphadenectomy without further axillary dissection in patients with sentinel node-negative breast cancer.  J Clin Oncol. 2000;  18 2553-2559
  • 16 Müller-Schimpfle M, Stoll P, Stern W, Huppert P E, Claussen C D. Präzise MR-gestützte präoperative Coil-Markierung von Mammaläsionen mit einer Standard-MR-Spule.  Fortschr Röntgenstr. 1998;  168 195-199

Dr. Gundula Staatz

Department of Diagnostic Radiology, Aachen University of Technology

Pauwelsstr. 30

52057 Aachen

Germany

Telefon: + 49-241-8088332

Fax: + 49-241-8082480

eMail: staatz@rad.rwth-aachen.de