Abstract
The objective of this study was to evaluate the variability of maximal heart rate in three different conditions: laboratory tests, field tests, and competitions. Sixteen male endurance volunteers were tested in five exhaustive tests for each condition. All exhaustive events were heart rate monitored (Accurex plus, Polar Electro, Finland) and true maximal heart rates were assessed and compared with each other and with predicted maximal heart rates. Results show that under the three conditions HRpeaks were not statistically different (p = 0.62, NS, Friedman test). Mean HRpeaks (SD) were: laboratory = 194.3 (7.8), field = 193.8 (11.8), competition = 192.3 (10.1) beats × min-1 . Conditions for reaching individual heart rate peak were in the laboratory (treadmill V˙O2 max protocol) for 5 subjects, in field tests for 7 subjects and in competitions for 6 subjects (two circumstances for two subjects). A large intra-individual variation existed in the three circumstances (± 6 beats × min-1 ). Absolute median maximal heart rate was 190.0 bpm (9.32) i.e 7.6 bpm lower than heart rate peak. Both were highly related (rho = 0.89, z = 3.449, p = 0.0006, Spearman test). Median maximal heart rates inter-condition relationship were higher. Median maximal heart rate was more stable and took more information into account than an isolated peak. It gives a central value that minimizes the potential risk of under or over estimation when calibrating exercise intensities with HR.
Key words
Exercise intensity - maximal heart rate - treadmill - exhaustive tests - median maximal heart rate
References
1 American College of Sports Medicine .ACSM's Guidelines for Exercise Testing and Prescription. Baltimore; Williams & Wilkins 1995 5th ed
2
Arts F JP, Kuipers H.
The relation between power output, oxygen uptake and heart rate in males athletes.
Int J Sports Med.
1994;
15
228-231
3
Astrand P O, Rhyming I.
A nomogram for calculation of aerobic capacity (physical fitness) from pulse rate during submaximal work.
J Appl Physiol.
1954;
7
218-221
4
Astrand P O, Saltin B.
Oxygen uptake during the first minutes of heavy muscular exercise.
J Appl Physiol.
1961;
16
971-976
5
Barbeau P, Seresse O, Boulay M R.
Using maximal and submaximal aerobic variables to monitor elite cyclists during a season.
Med Sci Sports Exerc.
1993;
25
1062-1069
6
Basset F A, Boulay M R.
Specificity of treadmill and cycle ergometer tests in triathletes, runners and cyclists.
Eur J Appl Physiol.
2000;
81
214-221
7
Billat V, Koralstztein J P.
Significance of the velocity at V˙O2 max and time to exhaustion at this velocity.
Sports Med.
1996;
22
90-108
8 Lacour J R. Biology de l'exercice musculaire. Sous la direction de JR Lacour. Masson. 4ème edition
9
Bouchard C, Godbout P, Mondor J C, Leblanc C.
Specifity of maximal aerobic power.
Eur J Appl Physiol.
1979;
40
85-93
10
Boudet G, Chamoux A.
Heart rate monitors and abnormal rhythms detection.
Arch Int Physiol Biochem.
2000;
108 - 4
371-379
11
Boudet G, Chamoux A.
Analyse en laboratoire de certains cardiofréquencemètres.
Science et Sports.
2001;
16
51-52
12
Boulay M R.
Physiological monitoring of elite cyclists.
Sports Med.
1995;
20
1-11
13
Boulay M R, Simoneau J A, Lortie G, Bouchard C.
Monitoring high-intensity endurance exercise with heart rate and thresholds.
Med Sci Sports Exerc.
1997;
29
125-132
14
Brisswalter J, Legros P.
Daily stability in energy coast of running, respiratory parameters and stride rate among well-trained middle distance runners.
Int J Sports Med.
1994;
15
238-241
15 Carré F, Beillot J, Rochcongar P, Dassonville J, Lessard Y, Lebars R. La capacité aérobie du vétéran entraîné. In: Médecine du sport 1988. Paris; Expansion Scientifique Française 1988: 80-85
16
Chamoux A.
Les appareils de mesure de la fréquence cardiaque au travail: Performances et critères de choix.
Rev Med Travail.
1990;
17
65-69
17
Chamoux A, Berthon P, Laubignat J F.
Determination of maximum aerobic velocity by a 5-minute test with reference to world running records. A theoretical approach.
Arch Int Physiol Bioch.
1996;
104
207-211
18
Cumming G R, Boryssyk L M.
Criteria for maximum oxygen uptake in men over 40 in a population survey.
Med Sci Sports Exerc.
1972;
14
18-22
19
Duncan G E, Howley E T, Johnson B N.
Applicability of V˙O2 max criteria: discontinuous versus continuous protocols.
J Appl Physiol.
1974;
36
720-725
20
Gilman M B.
The use of heart rate to monitor the intensity of endurance training.
Sports Med.
1996;
21
73-79
21
Hammond H K, Froelicher V F.
Normal and abnormal heart rate responses to exercise.
Prog Cardiovasc Dis.
1985;
26
271-296
22
Hermansen L, Saltin B.
Oxygen uptake during maximal treadmill and bicycle exercise.
J Appl Physiol.
1969;
26
31-37
23
Karvonen J, Vuorimaa T.
Heart rate and exercise intensity during sports activities. Practical application.
Sports Med.
1988;
5
303-312
24
Khort W M, Morgan D W, Bates B, Skinner J.
Physiological responses of triathletes to maximal swiming, cycling, and running.
Med Sci Sports Exerc.
1987;
19
51-55
25
Kuipers H, Verstappen F T, Keizer H A.
Variability of aerobic performance in the laboratory and its physiological correlates.
Int J Sports Med.
1985;
6
197-201
26
Lambert M I, Mbambo Z H, St Clair Gibson A.
Heart rate during training and competition for long distance running.
J Sports Sci.
1998;
16
85-90
27
Laukkanen R, Virtanen P.
Heart rate monitors: State of the art.
J Sports Sci.
1998;
16
3-7
28
Leger L, Thivierge M.
Heart rate monitors: Validity, Stability and Functionality.
Phys Sportsmed.
1988;
16
143-151
29
Londeree B R, Moeschberger M L.
Effect of age and other factors on maximal heart rate.
Res Q Exerc Sport.
1982;
53
297-304
30
Martinez M L, Modrego A, Ibanez Santos J, Grijalba A, Santesteban M D, Gorostiago E M.
Physiological comparison of roller skating, treadmill running and ergometer cycling.
Int J Sports Med.
1993;
14
72-77
31
McArdle W D, Magel J R.
Physical work capacity and maximum oxygen uptake in treadmill and bicycle exercise.
Med Sci Sports Exerc.
1970;
2
118-123
32
McConnel T R.
Practical considerations in testing of V˙O2 max in runners.
Sports Med.
1988;
5
57-68
33
Palmer G, Hawley J A, Dennis S, Noakes T D.
Heart rate response during a 4-day cycle race.
Med Sci Sports Exerc.
1994;
26
1278-1283
34
Schneider D A, Lacroix K A, Atkinson G R, Troped P J, Pollack J.
Ventilatory threshold and maximal oxygen uptake during cycling and running in triathletes.
Med Sci Sports Exerc.
1990;
22
257-264
35
St Clair Gibson A, Broomhead S A, Hawley J A, Lambert M I, Noakes T D.
Is heart rate data during field testing reliable? A study of repeatability of heart rate data in different sporting populations.
J Sports Sci.
1998;
16
109
36
Swain D P, Brian C, Leutholtz B C, King M E, Hass L A, Branch J D.
Relationship between % heart rate reserve and %VO2 reserve in treadmill exercise.
Med Sci Sports Exerc.
1998;
30
318-321
37
Veicsteinas A, Feroldi P, Dotti A.
Ventilatory response during incremental exercise tests in weight lifters and endurance cyclists.
Eur J Appl Physiol.
1985;
53
322-329
38
Vidalin H, Fellmann N, Leymonie R, Bedu M, Michel J, Fanget M, Coudert J.
Consommation maximale d'oxygène directe et indirecte. Fréquence cardiaque maximale réelle et théorique.
Sci Sports.
1989;
4
71-77
39
Weltman A, Snead D, Seip R, Schurrer R, Weltman J, Rutt R, Rogol A.
Percentage of maximal heart rate, Heart rate reserve and V˙O2 max for determining endurance training intensity in male runners.
Int J Sports Med.
1990;
11
218-222
40
Whaley M H, Kaminsky L A, Dwyer G B, Getchell L H, Norton J A.
Predictors of over-and underachievement of age-predicted maximal heart rate.
Med Sci Sports Exerc.
1992;
24
1173-1179
41
Zhou S, Robson S J, Davie A J.
Correlations between short-course triathlon performance and physiological variables determined in laboratory cycle and treadmill tests.
J Sports Med Phys Fitness.
1997;
37
122-130
G. Boudet
13, rue Guynemer · 63110 Beaumont · France ·
Telefon: +33 4 73 26 52 56
eMail: Gil.Boudet@wanadoo.fr