Background Suppression Using Magnetization preparation for Contrast-enhanced 3D MR angiography of the pelvic and lower leg arteries

Präparation der Längsmagnetisierung zur Hintergrundsuppression in der kontrastverstärkten 3D-MR-Angiographie der Becken-Bein-ArterienJ.  T.  Winterer1 , R.  Strecker1 , C.  Lohrmann1 , O.  Schaefer1 , N.  Ghanem1 , T.  Bley1 , E.  Kotter1 , S.  Lehnhardt1 , J.  Hennig1
  • 1Department of Diagnostic Radiology, University of Freiburg
Further Information

Publication History

Publication Date:
14 January 2003 (online)

Zusammenfassung

Zielsetzung: Entwicklung und Evaluation einer 3D-Gradientenechosequenz mit implementierter Hintergrundsuppression für die kontrastverstärkte Magnetresonanzangiographie unter Verwendung nicht-selektiver Präparations-Pulse. Methoden: Am 1.5-T-Kernspintomographen wurde eine segmentierte, ultraschnelle gespoilte 3D-MR-Angiographiesequenz (FLASH) mit nicht-selektiven Inversionspulsen zur Hintergrundsuppression implementiert. Bei 11 Patienten erfolgte die Gadolinium-BOPTA-verstärkte MR-Angiographie der Becken-Bein-Arterien unter Verwendung des AngioSURF-Rolltisches. Die rekonstruierten Einzelschichten wurden hinsichtlich des Gefäßkontrastes sowie der Qualität der Gefäßdarstellung und Hintergrundsuppression analysiert. Ergebnisse: In allen Gefäßetagen konnte eine hervorragende Hintergrundsuppression und selektive Gefäß-Kontrastierung erzielt werden. Das Protokoll war schnell und komfortabel durchführbar, wobei die nicht erforderliche Akquisition von Nativ-Serien eine deutliche Vereinfachung des Untersuchungsablaufes darstellte. Schlussfolgerung: Mittels nicht-selektiven Inversionspulsen kann eine effiziente Suppression des Hintergrundsignals in der kontrastverstärkten 3D-Magnetresonanz-angiographie der Becken-Bein-Region erzielt werden. Auf die bewegungsanfällige Subtraktionstechnik kann auch bei der Untersuchung der unteren Extremitäten verzichtet werden; somit ist eine deutliche Vereinfachung von Tischverschiebeprotokollen möglich.

Abstract

Purpose: To develop and evaluate non-slab-selective magnetization preparation in contrast-enhanced 3D-MR angiography. Methods: An ultrafast spoiled mr angiography sequence (FLASH) with non-selective inversion prepulses for background suppression was implemented on a 1.5 T MR system. In 11 patients gadobenate dimeglumine-enhanced mr-angiography of the pelvic and lower leg arteries was performed using the AngioSURF device. Source data was evaluated for contrast-to-noise-ratio, image quality and the extent of background suppression. Results: Background suppression and selective vessel contrast was excellent in all vascular levels. The mr protocol was comfortable and easy-to-handle. Abandonment of precontrast-series acquisition simplified the examination procedure markedly. Conclusions: Magnetization preparation provides efficient suppression of the background signal in contrast-enhanced 3D mr angiography of the pelvic and lower leg arteries. Since no subtraction technique is needed, moving-bed and whole body MRA-protocols can be simplified significantly.

References

  • 1 Ruehm S G, Nanz D, Baumann A, Schmid M, Debatin J F. 3D contrast-enhanced MR angiography of the run-off vessels: value of image subtraction.  J Magn Reson Imaging.. 2001;  13 (3) 402-411
  • 2 Leung D A, Pelkonen P, Hany T F, Zimmermann G, Pfammatter T, Debatin J F. Value of image subtraction in 3D gadolinium-enhanced MR angiography of the renal arteries.  J Magn Reson Imaging. 1998;  8 598-602
  • 3 Parker D L, Buswell H R, Goodrich K C, Alexander A L, Keck N, Tsuruda J S. The application of magnetization transfer to MR angiography with reduced total power.  Magn Reson Med. 1995;  34 283-286
  • 4 Wilman A H, Huston J 3rd, Riederer S J. Three-dimensional magnetization-prepared time-of-flight MR angiography of the carotid and vertebral arteries.  Magn Reson Med. 1997;  37 252-259
  • 5 Yamashita Y, Mitsuzaki K, Tang Y, Namimoto T, Takahashi M. Gadolinium-enhanced breath-hold three-dimensional time-of-flight MR angiography of the abdominal and pelvic vessels: the value of ultrafast MP-RAGE sequences.  J Magn Reson Imaging. 1997;  7 623-628
  • 6 Bos C, Bakker C JG, Viergever M A. Background Suppression Using Magnetization Preparation for Contrast-Enhanced MR Projection Angiography.  Magnetic Resonance in Medicine. 2001;  46 78-87
  • 7 Ruehm S G, Goyen M, Quick H H. et al . [Whole-body MRA on a rolling table platform (AngioSURF)].  Roefo Fortschr Geb Roentgenstr Neuen Bildgeb Verfahr. 2000;  172 670-674
  • 8 Goyen M, Quick H H, Debatin J F, Ladd M E, Barkhausen J, Herborn C U, Bosk S, Kuehl H, Schlepütz M, Ruehm S G. Whole-body three-dimensional MR angiography with a rolling table platform: initial clinical experience.  Radiology. 2002;  224 270-277
  • 9 Prince M R. Gadolinium-enhanced MR aortography.  Radiology. 1994;  191 155-164
  • 10 Kirchin M A, Pirovano G P, Spinazzi A. Gadobenate dimeglumine (Gd-BOPTA). An overview.  Invest Radiol. 1998;  33 798-809
  • 11 Goyen M, Herborn C U, Lauenstein T C, Barkhausen J, Veit P, Bosk S, Debatin J F, Ruehm S G. Optimization of Contrast Dosage for Gadobenate Dimeglumine-Enhanced High-Resolution Whole-Body 3D Magnetic. Resonance Angiography.  Invest Radiol. 2002;  37 263-268

Jan Thorsten WintererM.D. 

Dept. of Diagnostic Radiology

Hugstetter Straße 55
79106 Freiburg, Germany

Phone: +49/761/270/3945

Fax: +49/761/270/3956

Email: jan.winterer@klinikum.uni-freiburg.de