Zusammenfassung

Ziel: Vorstellung einer neu entwickelten Software (YACTA - yet another CT analyzer) zur Detektion und Quantifizierung des Lungenemphysems in der Dünnschicht-CT der Lunge. Material und Methoden: Das auf Schwellenwertverfahren (z. B. Bereichswachstumsverfahren), Expertenregeln und morphologischer Bildverarbeitung basierende Werkzeug detektiert zunächst den Tracheobronchialbaum, bevor das Lungenemphysem detektiert und quantifiziert wird. Hier wurde eine Fehlerkorrektur integriert, welche Bildrauschen kompensiert. Neben den globalen Parametern mittlere Lungendichte (MLD) und Emphysemindex (EI, auch „Pixelindex”- PI) wurde der vorbeschriebene Bullae-Index (BI) zur morphologischen Beschreibung des Emphysems in einen dreidimensionalen Ansatz transformiert. Es erfolgte eine erste Evaluation an MD-CT-Daten von 11 Patienten sowie der Vergleich der mittleren Lungendichte (MLD), Lungenvolumen (LV), Emphysemvolumen (EV) und Pixelindex (PI) mit Werten, die durch zwei etablierte Anwendungen der Firma Siemens Medical Solutions (Volume© und Pulmo©) erhoben wurden, sowie die Berechnung des Bullae-Index (BI) mittels YACTA. Ergebnisse: YACTA arbeitete an den vorliegenden Bilddaten ohne die Notwendigkeit einer manuellen Korrektur und bietet somit einen deutlich höheren Bedienkomfort als die Vergleichsanwendungen, welche besonders am Lungenhilus häufiger Korrekturen zur Trennung von Lunge und Atemwegen nötigten. Die ermittelten MLD-Werte/Lungen-/Emphysemvolumina lagen bei YACTA systematisch höher als bei den Vergleichsanwendungen (Pulmo©: + 50 HE/+ 597 ml/+ 159 ml; Volume©: + 32 HE/+ 110 ml/+ 155 ml). Ursächlich hierfür sind unterschiedliche Segmentierungsalgorithmen: YACTA schließt Areale ein, die bei der rein dichtebasierten Volumenbestimmung nicht erfasst werden. Konstant niedrigere Lungenvolumina unter Pulmo© sind zusätzlich auf eine fehlende Dilatation zurückzuführen. Die deutlich erhöhten medianen Emphysemvolumina und -indizes unter YACTA beruhen auf der neuartigen Fehlerkorrektur. Die Segmentierung des Tracheobronchialbaums senkt den Anteil an irrtümlich als Emphysem klassifizierten Atemwegen. Schlussfolgerung: Das neu entwickelte Programm überbietet herkömmliche, halbautomatische Lösungen an Komfort und liefert vergleichbare, gering bis mäßig differierende Ergebnisse bezüglich der Lungen- und Emphysemvolumina, der MLD und des Emphysemindex. Zusätzlich ist eine vollautomatische Berechnung des Bullae Index, der Aussagen über die bullöse Morphologie des Emphysems macht, möglich. Weitere Studien zur Korrelation der ermittelten Werte mit klinischen und pathologischen Parametern sind notwendig.

Abstract

Purpose: Introduction of a novel software tool (YACTA - yet another CT analyzer) for detection and quantification of pulmonary emphysema in thin-slice chest MDCT data sets. Materials and Methods: Consisting of grey-level threshold-based algorithms (e. g., region-growing), expert rules and morphological image postprocessing YACTA segments the tracheobronchial tree prior to the detection and quantification of pulmonary emphysema. In addition to general parameters, such as the mean lung density (MLD) and the emphysema index (EI - also described as pixel index PI), the previously described bullae index (BI) is transformed into a three-dimensional parameter for a morphological description of emphysema. A first evaluation of chest MDCT data sets of 11 patients was performed as well as a comparison of MLD, lung volume (LV), emphysema volume (EV) and PI calculated with two established commercial tools of Siemens Medical Solutions (Volume© and Pulmo©). Furthermore, the BI was calculated with YACTA. Results: YACTA processed the image data without manual interaction and demonstrated more user-comfort than Volume© and Pulmo© software, which require manual correction especially for lung segmentation at the hilar regions to separate central airways from lung parenchyma. MLD, LV, and EV values calculated with YACTA were systematically higher (Pulmo©: + 50 HU/+ 597 ml/+ 159 ml; Volume©: + 32 HU/+ 110 ml/+ 155 ml). Different segmentation algorithms are responsible for this: YACTA includes areas not assessed by mere threshold-based techniques. Constantly lowered LV values of Pulmo© are caused by a missing dilatation algorithm. The error correction as a special feature of YACTA results in increased emphysema volumes and indices. The segmentation of the tracheobronchial tree lowers the part of airways falsely classified as emphysema. Conclusion: The new developed software shows higher user comfort as established by semi-automated tools. Results of LV, EV, MLD and PI are comparable or moderately different. Automatic calculation of a BI is possible, providing information about bullous morphology of pulmonary emphysema. Further studies are necessary to correlate data with clinical or pathological parameters.

Literatur

  • 1 Archer D C, Coblentz C L, deKemp R A. et al . Automated in vivo quantification of emphysema.  Radiology. 1993;  188 (3) 835-838
  • 2 Kalender W A, Fichte H, Bautz W. et al . Semiautomatic evaluation procedures for quantitative CT of the lung.  Journal of Computed Tomography. 1991;  15 248-255
  • 3 Uppaluri R, Mitsa T, Sonka M. et al . Quantification of pulmonary emphysema from lung computed tomography images.  Am J Respir Crit Care Med. 1997;  156 248-254
  • 4 Riga B, Andres A L, Stramare R. Density-mask spiral computed tomography in patients who are candidates for a lung-volume-reduction intervention: a preliminary study.  Radiol Med. 2000;  99 150-155
  • 5 Achenbach T, Vomweg T, Heussel C P. et al . Computerunterstützte Diagnostik in der Thoraxradiologie - aktuelle Schwerpunkte und Techniken.  Fortschr Röntgenstr. 2003;  175 1471-1481
  • 6 Peitgen H O, Krass S, Lang M. Computerunterstützung in der klinischen, bildbasierten Diagnostik und Therapie: Herausforderungen für den Forschungsstandpunkt Deutschland.  Fortschr Röntgenstr. 2004;  176 (3) 297-301
  • 7 Stolk J, Dirksen A, van der Lugt A A. et al . Repeatability of lung density measurements with low-dose computed tomography in subjects with alpha-1-antitrypsin deficiency-associated emphysema.  Invest Radiol. 2001;  36 (11) 648-651
  • 8 Uppaluri R, Hoffman E A, Sonka M. et al . Interstitial Lung Disease.  Am J Respir Crit Care Med. 1997;  159 519-525
  • 9 Blechschmidt R A, Werthschutzky R, Lorcher U. Automated CT image evaluation of the lung: a morphology-based concept.  IEEE Trans Med Imaging. 2001;  20 434-442
  • 10 Beier J, Bittner R C, Hosten N. et al . Morphologische Bildverarbeitungsoperatoren - Reduktion von Partialvolumenartefakten für eine verbesserte dreidimensionale Visualisierung von CT-Untersuchungen.  Radiologe. 1998;  38 860-866
  • 11 Kauczor H U, Heussel C P, Mildenberger P. et al . Was heißt wie? Ansatz und Glossar zu Befundung und Verständnis in der HRCT der Lunge.  Fortschr Röntgenstr. 1996;  165 428-437
  • 12 Cederlund K, Bergstrand L, Hogberg S. et al . Visual grading of emphysema severity in candidates for lung volume reduction surgery. Comparison between HRCT, spiral CT and „density-masked” images.  Acta Radiol. 2002;  43 (1) 48-53
  • 13 Sashidhar K, Gulati M, Gupta D. et al . Emphysema in heavy smokers with normal chest radiography. Detection and quantification by HCRT.  Acta Radiol. 2002;  43 (1) 60-65
  • 14 Markstaller K, Arnold M, Döbrich M. et al . Software zur automatischen Quantifizierung von Belüftungszuständen bei akutem Lungenversagen in dynamischen CT-Aufnahmen der Lunge.  Fortschr Röntgenstr. 2001;  173 830-835
  • 15 Zagers R, Vrooman H A, Aarts N JM. et al . Quantitative Analysis of Computed Tomography Scans of the Lungs for the Diagnosis of Pulmonary Emphysema - A Validation Study of a Semiautomated Contour Detection Technique.  Investigative Radiology. 1995;  30 (9) 552-562
  • 16 Malbouisson L M, Muller J C, Constantin J M. et al . Computed Tomography Assessment of Positive End-expiratory Pressure-induced Alveolar Recruitment in Patients with ARDS.  Am J Respir Crit Care Med. 2001;  163 1444-1450
  • 17 Remy-Jardin M, Campistron P, Amara A. et al . Usefulness of coronal reformations in the diagnostic evaluation of infiltrative lung disease.  J Comput Assist Tomogr. 2003;  27 (2) 266-273
  • 18 Biernacki W, Redpath A T, Best J J. et al . Measurement of CT lung density in patients with chronic asthma.  Eur Respir J. 1997;  10 (11) 2455-2459
  • 19 Stolk J, Dirksen A, van der Lugt A A. et al . Repeatability of lung density measurements with low-dose computed tomography in subjects with alpha-1-antitrypsin deficiency-associated emphysema.  Invest Radiol. 2001;  36 (11) 648-651
  • 20 Hoffman E A, Reinhardt J M, Sonka M. et al . Characterization of the interstitial lung diseases via density-based and texture-based analysis of computed tomography images of lung structure and function.  Acad Radiol. 2003;  10 (10) 1104-1118

T. Achenbach

Klinik und Poliklinik für Radiologie, Johannes Gutenberg-Universität

55101 Mainz

Email: achenbac@uni-mainz.de