Endoscopy 2004; 36(10): 913-920
DOI: 10.1055/s-2004-825868
ESGE Position Paper
© Georg Thieme Verlag Stuttgart · New York

The Role of Video Capsule Endoscopy in the Diagnosis of Digestive Diseases: a Review of Current Possibilities

G.  Gay1 , M.  Delvaux1 , J-. F.  Rey2
  • 1Dept. of Internal Medicine, Centre Hospitalier Universitaire de Brabois, Vandoeuvre-les-Nancy, France
  • 2Arnault Tzanck Institute, Saint-Laurent du Var, France
Further Information

Publication History

Publication Date:
28 September 2004 (online)

Video capsule endoscopy represents a significant advance in the investigation of intestinal diseases. The performance of the procedure and indications are reviewed here in order to establish guidelines for its use, in accordance with current knowledge from the published literature. Capsule endoscopy is performed in patients who have fasted for 12 h, but who are allowed to drink 2 h after and to eat 4 h after ingesting the capsule. Software features highlighting suspected blood and allowing simultaneous viewing of two images reduce the time required to review the findings, as well as improving the diagnostic yield. Pacemakers and other electrical medical devices are no longer a contraindication to the procedure. Indications that have been validated include obscure digestive bleeding, intestinal lesions related to nonsteroidal anti-inflammatory drugs, and familial polyposis. Capsule endoscopy frequently detects intestinal lesions in patients with Crohn’s disease and could become the first-choice examination in patients with suspected Crohn’s disease after conventional endoscopic investigations. Other indications currently under evaluation include celiac disease, pediatric indications, and examination of other parts of the gastrointestinal tract.

References

  • 1 Waye J D. Small bowel endoscopy.  Endoscopy. 1992;  24 68-72
  • 2 Krevsky B. Enteroscopy: exploring the final frontier.  Gastroenterology. 1991;  100 838-839
  • 3 Gay G J, Delmotte J S. Enteroscopy in small intestinal inflammatory diseases.  Gastroenterol Clin N Am. 1999;  9 115-123
  • 4 Perez-Cuadrado E, Macenlle R, Iglesias J. et al . Usefulness of oral video push enteroscopy in Crohn’s disease.  Endoscopy. 1997;  29 745-747
  • 5 Barkin J S, Chong J, Reiner D K. First-generation video enteroscope: fourth-generation push-type small bowel enteroscopy utilizing an overtube.  Gastrointest Endosc. 1994;  40 743-747
  • 6 Berner J S, Mauer K, Lewis B S. Push and sonde enteroscopy for the diagnosis of obscure gastrointestinal bleeding.  Am J Gastroenterol. 1994;  89 2139-2142
  • 7 Lewis B S, Kornbluth A, Waye J D. Small bowel tumours: yield of enteroscopy.  Gut. 1991;  32 763-765
  • 8 Zaman A, Sheppard B, Katon R M. Total peroral intraoperative enteroscopy for obscure GI bleeding using a dedicated push enteroscope: diagnostic yield and patient outcome.  Gastrointest Endosc. 1999;  50 506-510
  • 9 Hoffman J S, Cave D R, Birkett D. Intra-operative enteroscopy with a sonde intestinal fiberscope.  Gastrointest Endosc. 1994;  40 229-230
  • 10 May A, Nachbar A, Wardak H. et al . Double-balloon enteroscopy: preliminary experience in patients with obscure gastrointestinal bleeding or chronic abdominal pain.  Endoscopy. 2003;  35 985-991
  • 11 Zuckerman G R, Prakash C, Askin M P, Lewis B S. AGA technical review on the evaluation and management of occult and obscure gastrointestinal bleeding.  Gastroenterology. 2000;  118 201-221
  • 12 Moch A, Herlinger H, Kochman M L. et al . Enteroclysis in the evaluation of obscure gastrointestinal bleeding.  AJR Am J Roentgenol. 1994;  163 1381-1384
  • 13 Antes G. [Barium examinations of the small intestine and the colon in inflammatory bowel disease; in German.]  Radiologe. 2003;  43 9-16
  • 14 Wiesner W, Steinbrich W. [Imaging diagnosis of inflammatory bowel disease; in German.]  Ther Umsch. 2003;  60 137-144
  • 15 Van Gossum A. Obscure digestive bleeding.  Best Pract Res Clin Gastroenterol. 2001;  15 155-174
  • 16 Leitman I M, Paull D E, Shires G T III. Evaluation and management of massive lower gastrointestinal hemorrhage.  Ann Surg. 1989;  209 175-180
  • 17 Whitaker S C, Gregson R H. The role of angiography in the investigation of acute or chronic gastrointestinal haemorrhage.  Clin Radiol. 1993;  47 382-388
  • 18 Rieber A, Wruk D, Potthast S. et al . Diagnostic imaging in Crohn’s disease: comparison of magnetic resonance imaging and conventional imaging methods.  Int J Colorectal Dis. 2000;  15 176-181
  • 19 Woodard P K, Feldman J M, Paine S S, Baker M E. Midgut carcinoid tumors: CT findings and biochemical profiles.  J Comput Assist Tomogr. 1995;  19 400-405
  • 20 Laurent F, Raynaud M, Biset J M. et al . Diagnosis and categorization of small bowel neoplasms: role of computed tomography.  Gastrointest Radiol. 1991;  16 115-119
  • 21 Shoenut J P, Semelka R C, Silverman R. et al . Magnetic resonance imaging in inflammatory bowel disease.  J Clin Gastroenterol. 1993;  17 73-78
  • 22 Iddan G, Meron G, Glukhovsky A, Swain P. Wireless capsule endoscopy.  Nature. 2000;  405 417
  • 23 Meron G D. The development of the swallowable video capsule M2A.  Gastrointest Endosc. 2000;  52 817-819
  • 24 Halpern M, Jacob H. Atlas of capsule endoscopy. Yoqneam, Israel; Given Imaging 2002
  • 25 Gong F, Swain P, Mills T. Wireless endoscopy.  Gastrointest Endosc. 2000;  51 525-529
  • 26 Yu M. M2A capsule endoscopy: a breakthrough diagnostic tool for small intestine imaging.  Gastroenterol Nurs. 2002;  25 24-27
  • 27 Janssens J, Peeters T L, Vantrappen G. et al . Improvement of gastric emptying in diabetic gastroparesis by erythromycin: preliminary studies.  N Engl J Med. 1990;  322 1028-1031
  • 28 Fischer D, Schreiber R, Levi D et al. Capsule endoscopy: the localisation system.  Gastrointest Endoscopy Clin N Am. 2004;  14 25-31
  • 29 Liangpunsakul S, Mays L, Rex D K. Performance of Given suspected blood indicator.  Am J Gastroenterol. 2003;  98 2676-2678
  • 30 Ginsberg G G, Barkun A N, Bosco J J. et al . Wireless capsule endoscopy.  Gastrointest Endosc. 2002;  56 621-624
  • 31 Liangpunsakul S, Chadalawada V, Rex D K. et al . Wireless capsule endoscopy detects small bowel ulcers in patients with state of the art normal enteroclysis.  Am J Gastroenterol. 2003;  98 1295-1298
  • 32 Adamek H E, Hartmann D, Hahne M. et al . [Endoscopy of the small intestine without tube or enema? A video capsule makes it possible; in German.]  MMW Fortschr Med. 2002;  144 34-35
  • 33 Lewis B S, Swain P. Capsule endoscopy in the evaluation of patients with suspected small intestinal bleeding: results of a pilot study.  Gastrointest Endosc. 2002;  56 349-353
  • 34 Costamagna G, Shah S K, Riccioni M E. et al . A prospective trial comparing small bowel radiographs and video capsule endoscopy for suspected small bowel disease.  Gastroenterology. 2002;  123 999-1005
  • 35 Ell C, Remke S, May A. et al . The first prospective controlled trial comparing wireless capsule endoscopy with push enteroscopy in chronic gastrointestinal bleeding.  Endoscopy. 2002;  34 685-689
  • 36 Saurin J C, Delvaux M, Gaudin J L. et al . Diagnostic value of endoscopic capsule in patients with obscure digestive bleeding: blinded comparison with video push enteroscopy.  Endoscopy. 2003;  35 576-584
  • 37 Voderholzer W A, Ortner M, Rogalla P. et al . Diagnostic yield of wireless capsule enteroscopy in comparison with computed tomography enteroclysis.  Endoscopy. 2003;  35 1009-1014
  • 38 Eliakim R, Fischer D, Suissa A. et al . Wireless capsule video endoscopy is a superior diagnostic tool in comparison to barium follow-through and computerized tomography in patients with suspected Crohn’s disease.  Eur J Gastroenterol Hepatol. 2003;  15 363-367
  • 39 Mylonaki M, Fritscher-Ravens A, Swain P. Wireless capsule endoscopy: a comparison with push enteroscopy in patients with gastroscopy and colonoscopy-negative gastrointestinal bleeding.  Gut. 2003;  52 1122-1126
  • 40 Hartmann D, Schilling D, Bolz G et al. Capsule endoscopy versus push enteroscopy in patients with occult gastrointestinal bleeding.  Z Gastroenterol. 2003;  41 377-382
  • 41 Appleyard M, Glukhovsky A, Swain P. Wireless-capsule diagnostic endoscopy for recurrent small-bowel bleeding.  N Engl J Med. 2001;  344 232-233
  • 42 Lewis B S. Enteroscopy: endangered by the capsule?.  Endoscopy. 2002;  34 416-417
  • 43 Pennazio M. Small bowel endoscopy.  Endoscopy. 2004;  36 32-41
  • 44 American Gastroenterological Association . Medical position statement: evaluation and management of occult and obscure gastrointestinal bleeding.  Gastroenterology. 2000;  118 197-200
  • 45 Scapa E, Jacob H, Lewkowicz S. et al . Initial experience of wireless-capsule endoscopy for evaluating occult gastrointestinal bleeding and suspected small bowel pathology.  Am J Gastroenterol. 2002;  97 2776-2779
  • 46 Pennazio M, Santucci R, Rondonotti E. et al . Outcome of patients with obscure gastrointestinal bleeding after capsule endoscopy: report of 100 consecutive cases.  Gastroenterology. 2004;  126 643-653
  • 47 Fireman Z, Mahajna E, Broide E. et al . Diagnosing small bowel Crohn’s disease with wireless capsule endoscopy.  Gut. 2003;  52 390-392
  • 48 Herreiras J M, Caunedo A, Rodriguez-Tellez M. et al . Capsule endoscopy in patients with suspected Crohn’s disease in negative endoscopy.  Endoscopy. 2003;  35 1-5
  • 49 Rösch T. Capsule endoscopy.  Endoscopy. 2003;  35 816-822
  • 50 Gay G, Delvaux M, Fassler I et al. Location of the colonic origin of bleeding with the wireless endoscope in one patient with obscure intestinal bleeding.  Gastrointest Endosc.. 2002;  56 758-762
  • 51 Neu B, Wettschureck E, Rösch T. Is esophageal capsule endoscopy feasible? Results of a pilot study.  Endoscopy. 2003;  35 957-961
  • 52 Mergener K, Enns R, Brandabur J J, Schembre D B, Smith M. Complications and problems with capsule endoscopy: Results from two referral centers.  Gastrointest Endosc. 2003;  57 (abstract) AB171
  • 53 Barkin J S. Wireless Capsule Endoscopy requiring Surgical Intervention: The World's Experience.  Am J Gastroenterol. 2002;  97 (abstract) 907
  • 54 Goldfarb N I, Phillips A, Conn M , Lewis B S, Nash D B. Economic and Health Outcomes of Capsule Endoscopy: Opportunities for improved Management of the Diagnostic Process for Obscure Gastrointestinal Bleeding.  Disease Management. 2002;  4 123-135
  • 55 Goldfarb N I, Phillips A, Conn M. et al . Economic and health outcomes of capsule endoscopy: opportunities for improved management of the diagnostic process for obscure gastrointestinal bleeding.  Dis Manag. 2002;  5 123-135
  • 56 Delvaux M, Friedman S, Cave D R. et al . Minimal standard terminology for capsule endoscopy (CE-MST): development and validation of a comprehensive thesaurus based on the analysis of 766 procedures examining the small bowel [abstract].  Gastrointest Endosc. 2003;  57 AB162

J- F. Rey, M. D.

Institut Arnault Tzanck

Avenue du Dr Maurice Donat · F-06700 Saint-Laurent du Var · France

Fax: +33-493075158

Email: jean-francois.rey@wandadoo.fr