Introductory Experience with the Continuous Glucose Monitoring System (CGMS®; Medtronic Minimed®) in Detecting Hyperglycemia by Comparing the Self-Monitoring of Blood Glucose (SMBG) in Non-Pregnant Women and in Pregnant Women with Impaired Glucose Tolerance and Gestational Diabetes
Publikationsverlauf
Received: October 15, 2003
First decision: February 12, 2004
Accepted: March 25, 2004
Publikationsdatum:
02. Dezember 2004 (online)
Abstract
Objective: To assess the detection rate of hyperglycemia with a continuous glucose monitoring system compared to a self-monitoring blood glucose profile in non-pregnant, non-diabetic pregnant women, and patients with impaired glucose tolerance or gestational diabetes..
Methods: Eight non-pregnant (NP) and 56 pregnant women (17 dietary-treated gestational diabetics (GDM), 15 women with impaired glucose tolerance (IGT), and 24 non-diabetic pregnant women (NDP)) underwent a 72-hour measurement with the CGMS® (Medtronic Minimed®, Northridge, CA, USA). Self-monitored blood glucose measurements, performed 30 minutes before and 120 minutes after each meal, were compared to the duration of hyperglycemia monitored by the continuous glucose monitoring system.
Results: No clinically observable infection was found at the subcutaneous tissue where the electrode was placed. A statistically significant difference was found between the groups in body mass index, HbA1c, and in gestational age, but not in age or parity. Using the self-monitored blood glucose (SMBG), 88 % (7/8) of the NP and 54 % (13/24) of the NDP had no measurement above 6.7 mmol/l. However, 17 % (4/24) of the NDP and 40 % (6/15) of the IGT showed more than two measurements above 6.7 mmol/l compared to 24 % (4/17) of the dietary-treated GDM. The differences between these groups were not significant (p = 0.21). The mean durations (± SD) of hyperglycemia above 6.7 mmol/l/24 h were: NP 111 ± 120 min, NDP 138 ± 120 min, IGT 381.8 ± 295 min, and GDM 190 ± 155 min, p = 0.017; above 7.8 mmol/l/24 h NP 24 ± 49 min, NDP 38 ± 47 min, IGT 170.7 ± 190 min, and GDM 64 ± 88 min, p = 0.016; and above 8.9 mmol/l/24 h NP 9.3 ± 25 min, NDP 7.5 ± 14 min, IGT 59 ± 77 min, and GDM 14 ± 21 min, p = 0.026. There was no significant difference in the fetal outcome or rate of birth percentiles using the sensor data.
Conclusions: The use of the sensor in pregnant women is unproblematic. a) The CGMS® detected more frequent and longer durations of hyperglycemia in GDM compared to non-diabetic pregnant women than the SMBG. b) Women with an IGT exhibited higher glucose levels than patients with gestational diabetes. c) The clinical importance of these hyperglycemic intervals, e.g. with respect to the risk for macrosomia, must be assessed in larger trials.
Key words
Gestational diabetes - CGMS - continuous glucose monitoring - screening - physiological glucose
References
- 1 American Diabetes Association . Gestational diabetes mellitus. Diabetes Care. 2001; 24 S77-S79
- 2 Cousins L, Rigg L, Hollingsworth D, Brink G, Aurand J, Yen S S. The 24-hour excursion and diurnal rhythm of glucose, insulin, and C-peptide in normal pregnancy. Am J Obstet Gynecol. 1980; 136 483-488
- 3 Combs C A, Gunderson E, Kitzmiller J L, Gavin L A, Main E K. Relationship of fetal macrosomia to maternal postprandial glucose control during pregnancy. Diabetes Care. 1992; 15 1251-1257
- 4 De Veciana M, Major C A, Morgna M A, Asrat T, Toohey J S, Lien J M, Evans A T. Postprandial versus preprandial blood glucose monitoring in women with gestational diabetes mellitus requiring insulin therapy. N Engl J Med. 1995; 333 1237-1241
- 5 German Diabetes Association .Guidelines of the working group Diabetes and Pregnancy (2001). http://www.deutsche-diabetes-gesellschaft.de, updated June 2001.
- 6 Gillmer M D, Beard R W, Brooke F M, Oakley N W. Carbohydrate metabolism in pregnancy. Part I. Diurnal plasma glucose profile in normal and diabetic women. Br Med J. 1975; 3 399-402
- 7 Jovanovic L. The role of continuous glucose monitoring in gestational diabetes mellitus. Diabetes Tech Ther. 2001; 2 S67-S71
- 8 Kjos S L, Buchanan T A. Gestational diabetes mellitus. N Engl J Med. 1999; 34 1749-1756
- 9 Koschinsky T, Heinemann L. Sensors for glucose monitoring: technical and clinical aspects. Diabetes Metab Res Rev. 2001; 17 113-123
- 10 Metzger B E, Coustan D R. The Organizing Committee. Summary and recommendations of the fourth international workshop conference on gestational diabetes mellitus. Diabetes Care. 1998; 21 B161-B167
- 11 Neiger R, Coustan D R. The role of repeat glucose tolerance test in the diagnosis of gestational diabetes. Am J Obstet Gynecol. 1991; 165 787-790
- 12 O'Sullivan J B, Mahan C M. Criteria for the oral glucose tolerance test in pregnancy. Diabetes. 1963; 13 278-285
- 13 Parretti E, Mecacci F, Papini M, Cioni R, Carignani L, Mignosa M, La Torre P, Mello G. Third-trimester maternal glucose levels from diurnal profiles in nondiabetic pregnancies. Diabetes Care. 2001; 24 1319-1323
- 14 Phelps R L, Metzger B E, Freinkel N. Carbohydrate metabolism in pregnancy. XVII. Diurnal profiles of plasma glucose, insulin, free fatty acids, triglycerides, cholesterol, and individual amino acids in late normal pregnancy. Am J Obstet Gynecol. 1981; 140 730-736
- 15 Sivan E, Weisz B, Homko C J, Reece A, Schiff E. One or two hours postprandial glucose measurements: Are they the same?. Am J Obstet Gynecol. 2001; 185 604-607
- 16 Verma A, Mitchell B F, Demianczuk N, Flowerdew G, Okun N B. Relationship between plasma glucose levels in glucose intolerant women and newborn macrosomia. J Matern Fetal Med. 1997; 6 187-193
MD Kai J. Bühling
Charité University Medicine Campus Virchow-Klinikum
Clinic of Obstetrics
Augustenburger Platz 1
13353 Berlin
Germany
Telefon: + 4930450564293
Fax: + 49 3 04 50 56 49 01
eMail: kai.buehling@charite.de