RSS-Feed abonnieren
DOI: 10.1055/s-2005-870264
ICCE Consensus for Capsule Retention
Publication sponsored by Given Imaging Ltd.Publikationsverlauf
Publikationsdatum:
27. September 2005 (online)
Introduction
Capsule endoscopy allows direct examination of the entire length of the small bowel in a noninvasive manner and has become the gold standard in evaluating suspected disease of the small bowel [1] [2]. Capsule retention remains a major concern for physicians performing capsule endoscopy, since it was postulated that retention could cause acute small-bowel obstruction and, even without obstruction, retention could lead to a need for surgery to remove the capsule. Thus, retention could theoretically lead to surgery in a patient who otherwise might have been treated medically for the same illness. This is especially felt to be true for patients with Crohn’s disease or nonsteroidal anti-inflammatory drug (NSAID) enteropathy. The working group reviewed the available published data on capsule endoscopy to determine the true incidence of retention and the reported incidence of acute capsule impaction leading to obstruction. From a review of these data, the working group devised a statement to guide physicians with regard to retention.
References
- 1 Ginsberg G G, Barkun A N, Bosco J J. et al . Technology status evaluation report: wireless capsule endoscopy. Gastrointest Endosc. 2002; 56 621-624
- 2 Leighton J A, Goldstein J, Hirota W. et al . Standards of Practice Committee of the American Society for Gastrointestinal Endoscopy. Obscure gastrointestinal bleeding. Gastrointest Endosc. 2003; 58 650-655
- 3 Buchman A L, Miller F H, Wallin A. et al . Video capsule endoscopy versus barium contrast studies for the diagnosis of Crohn’s disease recurrence involving the small intestine. Am J Gastroenterol. 2004; 99 2171-2177
- 4 Tang S J, Zanati S, Dubcenco E. et al . Capsule endoscopy regional transit abnormality: a sign of underlying small bowel pathology. Gastrointest Endosc. 2003; 58 598-602
- 5 Sears D M, Avots-Avotins A, Culp K. et al . Frequency and clinical outcome of capsule retention during capsule endoscopy for GI bleeding of obscure origin. Gastrointest Endosc. 2004; 60 822-827
- 6 Tang S J, Zanati S, Dubcenco E. et al . Capsule endoscopy regional transit abnormality revisited. Gastrointest Endosc. 2004; 60 1029-1032
- 7 Barkin J S, Friedman S. Wireless capsule endoscopy requiring surgical intervention: the world’s experience. Am J Gastroenterol. 2002; 97 A83
- 8 Pennazio M, Santucci R, Rondonotti E. et al . Outcome of patients with obscure gastrointestinal bleeding after capsule endoscopy: report of 100 consecutive cases. Gastroenterology. 2004; 126 643-653
- 9 Mow W S, Lo S K, Targan S R. et al . Initial experience with wireless capsule enteroscopy in the diagnosis and management of inflammatory bowel disease. Clin Gastroenterol Hepatol. 2004; 2 31-40
- 10 Fireman Z, Mahajna E, Broide E. et al . Diagnosing small bowel Crohn’s disease with wireless capsule endoscopy. Gut. 2003; 42 390-392
- 11 Eliachim R. Fischer D, Suissa A et al. Wireless capsule endoscopy is a superior diagnostic tool in comparison to barium follow through and computerized tomography in patients with suspected Crohn’s disease. Eur J Gastroenterol Hepatol. 2003; 15 353-357
- 12 Herrerias J M, Caunedo A, Rodriguez-Tellez M. et al . Capsule endoscopy in patients with suspected Crohn’s disease and negative endoscopy. Endoscopy. 2003; 25 564-568
- 13 Guilhon de Araujo Sant’Anna A M, Dubois J, Miron M C, Seidman E G. Wireless capsule endoscopy for obscure small-bowel disorders: final results of the first pediatric controlled trial. Clin Gastroenterol Hepatol. 2005; 3 264-270
- 14 Goldstein J L, Eisen G M, Lewis B. et al . Video capsule endoscopy to prospectively assess small bowel injury with celecoxib, naproxen plus omeprazole, and placebo. Clin Gastroenterol Hepatol. 2005; 3 133-141
- 15 Cheifetz A, Sachar D, Lewis B. Small bowel obstruction: indication or contraindication for capsule endoscopy. [Paper presented at the Digestive Disease Week meeting, May 15-20, 2004, New Orleans, Louisiana, USA.]
- 16 Voderholzer W, Beinhoelzl J, Rogalla P. et al . Small bowel involvement in Crohn’s disease: a prospective comparison of wireless capsule endoscopy and computed tomography enteroclysis. Gut. 2005; 54 369-373
- 17 Boivin M, Lochs H, Voderholzer W A. Does passage of the patency capsule indicate small bowel patency? A prospective clinical trial. Endoscopy. 2005; 37 808-815
- 18 Delvaux M, Ben Soussan E, Laurent V. et al . Clinical evaluation of the M2A patency capsule system before a capsule endoscopy procedure in patients with suspected intestinal stenosis. Endoscopy. 2005; 37 801-807
- 19 Spada C, Spera G, Riccioni M. et al . A novel diagnostic tool for detecting function patency of the small bowel: the Given patency capsule. Endoscopy . 2005; 37 793-800
B. S. Lewis, M.D.
UMass Memorial Health Care · University of Massachusetts Medical Center
55 Lake Avenue North · Worcester MA 01655 · USA
eMail: blair.lewis@mssm.edu