Technical Challenges
Capsule endoscopy (CE) has become a standard procedure for the evaluation of the small bowel, and in several studies has been shown to be superior to other diagnostic methods [1] [2] [3] [4] [5].
In spite of its great diagnostic accuracy, the yield of capsule endoscopy can be somewhat limited by two types of problem: firstly, the presence of dark intestinal contents in the distal small bowel, which may impair the visualization of the mucosa; and secondly slow gastric emptying and/or small bowel transit, which lead to the exhaustion of capsule batteries before the ileocecal valve is reached, thus causing incomplete small-bowel imaging in 17 - 25 % of cases [6] [7].
References
- 1 Pennazio M, Santucci R, Rondonotti E. et al . Outcome of patients with obscure gastrointestinal bleeding after capsule endoscopy: report of 100 consecutive cases. Gastroenterology. 2004; 126 643-653
- 2 Loftus E V, Jr. Capsule endoscopy for Crohn’s disease: ready for prime time?. Clin Gastroenterol Hepatol. 2004; 2 14-16
- 3 Liangpunsakul S, Maglinte D D, Rex D K. Comparison of wireless capsule endoscopy and conventional radiologic methods in the diagnosis of small bowel disease. Gastrointest Endosc Clin N Am. 2004; 14 43-50
- 4 Liangpumgsakul S, Chadalawada V, Rex D K. et al . Wireless capsule endoscopy detects small bowel ulcers in patients with normal results from state of the art enteroclysis. Am J Gastroenterol. 2003; 98 1295-1298
- 5 Herrerias J M, Caunedo A, Rodriguez-Tellez M. et al . Capsule endoscopy in patients with suspected Crohn’s disease and negative endoscopy. Endoscopy. 2003; 35 564-568
- 6 Rondonotti E, Abbiati C, Signorelli C. et al . Reaching the ileocecal valve during capsule enteroscopy is independent both from intestinal preparation with laxatives and from the use of prokinetic drugs prior to the exam. Gastroenterology. 2004; 126 A 461
- 7 Rondonotti E, Herrerias J M, Pennazio M. et al . Complications, limitations and failures of capsule endoscopy: a review of 733 cases. Gastrointest Endosc. 2005; [accepted for publication]
- 8 Viazis N, Sgouros S, Papaxoinis K. et al . Bowel preparation increases the diagnostic yield of capsule endoscopy: a prospective, randomized, controlled study. Gastrointest Endosc. 2004; 60 534-538
- 9 Niv Y, Niv G. Capsule endoscopy: role of bowel preparation in successful visualization. Scand J Gastroenterol. 2004; 39 1005-1009
- 10 Dai N, Gubler C, Hengstler P. et al . Improved capsule endoscopy after bowel preparation. Gastrointest Endosc. 2005; 61 28-31
- 11 O’Loughlin C, Sable A I, Alazmi W, Barkin J S. Comparison of polyethylene glycol-electrolyte lavage (PEG-EL) preparation versus standard preparation on small bowel mucosal visualization for wireless capsule endoscopy (WCE). Am J Gastroenterol. 2003; 98 AB 322
- 12 Kim Y S, Chun H J, Kim K O. et al . Comparison of two bowel preparations for capsule endoscopy: NPO versus PEG. Gastrointest Endosc. 2003; 57 AB 169
- 13 Fireman Z, Paz D. Capsule endoscopy: improving the transit time and the image view. Gastrointest Endosc. 2004; 59 AB 1807
- 14 Lapalus M, Saurin J, Mion F, Ponchon T. Prospective randomized single-blind trial on oral sodium phosphate efficacy for small intestine preparation before capsule endoscopy. Endoscopy. 2003; 35 A 183
- 15 Reymunde A, Rivera J, Santiago N. Can the use of tegaserod improve the quality of imaging as well as the amount of bowel visualized by wireless endoscopy capsule. Am J Gastroenterol. 2003; 98 AB 872
-
16 Coron E, Sacher-Huvelin S, Le Rhun M. et al .
Is preparation required before capsule endoscopy of the small bowel? Results of a pilot study. in: Proceedings of the 3rd International Conference on Capsule Endoscopy, Miami, Florida, 2003. Yoqneam, Israel; Given Imaging 2004: 63 -
17 Chong A, Miller A, Taylor A, Desmond P.
Randomised controlled trial of polyethylene glycol administration prior to capsule endoscopy. in: Proceedings of the 3rd International Conference on Capsule Endoscopy, Miami, Florida, 2003. Yoqneam, Israel; Given Imaging 2004: 57 - 18 Ben Soussan E, Antonietti M, Lecleire S, Savoye G. Influence of bowel preparation for capsule endoscopy: quality of examination and transit time. Gastrointest Endosc. 2004; 59 AB 1829
-
19 Shiotani A, Opekun O R, Graham D Y.
Improved visualization of the small intestine using capsule endoscopy. in: Proceedings of the 4th International Conference on Capsule Endoscopy, Miami, Florida, 2005. Yoqneam, Israel; Given Imaging 2005: 259 - 20 Selby W. Complete small bowel transit in patients: determining factors and improvement with metoclopramide. Gastrointest Endosc. 2005; 61 80-85
- 21 Stolpman D R, Fanning S, Faigel D O. Effect of phosphosoda preparation on gastric transit time for the given M2A capsule. Gastrointest Endosc. 2003; 57 AB 165
- 22 Keuchel M, Voderholzer W, Schenk G. et al . Domperidone shortens gastric transit time of video capsule endoscope. Endoscopy. 2003; 35 (Suppl II) A185
-
23 Fireman Z, Mahajna E, Fish L. et al .
Effect of erythromycin on gastric and small bowel transit time of video-capsule endoscopy. in: Proceedings of the 2nd International Conference on Capsule Endoscopy, Berlin, Germany, 2003. Yoqneam, Israel; Given Imaging 2003: 15 -
24 Romero J, Caunedo A, Alcazar J. et al .
Effect of phosphosoda bowel preparation on gastric and intestinal transit time measured with capsule endoscopy. in: Proceedings of the 3rd International Conference on Capsule Endoscopy, Miami, Florida, 2003. Yoqneam, Israel; Given Imaging 2004: 55 - 25 Schmelkin I. Tegaserod decreases small bowel transit times in patients undergoing capsule endoscopy. Gastrointest Endosc. 2004; 59 AB 1819
- 26 Coumaros D, Claudel L, Levy P, Doffoel M. Diagnostic value of capsule endoscopy (CE) in obscure digestive bleeding (ODB) and effect of erythromycin injection. Gastrointest Endosc. 2004; 59 AB 1823
-
27 Pons Beltrán V, González Suarez B, González Asanza C. et al .
Evaluation of different bowel preparations for the study with capsule endoscopy: preliminary results. in: Proceedings of the 4th International Conference on Capsule Endoscopy, Miami, Florida, 2005. Yoqneam, Israel; Given Imaging 2005: 255 -
28 Leung W K, Chan F KL, Fung S SL. et al .
Role of oral erythromycin on gastric and small bowel transit of capsule endoscopy. in: Proceedings of the 4th International Conference on Capsule Endoscopy, Miami, Florida, 2005. Yoqneam, Israel; Given Imaging 2005: 249 - 29 Fireman Z, Kopelman Y, Fish L. et al . Effect of oral purgatives on gastric and small bowel transit time in capsule endoscopy. Isr Med Assoc J. 2004; 6 521-523
- 30 Sachdev R, Hibberd P L, Mammen A, Cave D R. Reduction of gastric transit time of video capsule endoscopy by right lateral positioning. Gastrointest Endosc. 2004; 59 AB176
-
31 Oeyen M, Adolphs J.
Gastric passage of the capsule in relation to posture. in: Proceedings of the 4th International Conference on Capsule Endoscopy, Miami, Florida, 2005. Yoqneam, Israel; Given Imaging 2005: 253 -
32 O’Loughlin C, Slinde N.
The effect of patient positioning on complete small bowel examination rates with wireless capsule endoscopy: an interim analysis. in: Proceedings of the 4th International Conference on Capsule Endoscopy, Miami, Florida, 2005. Yoqneam, Israel; Given Imaging 2005: 149
R. de Franchis, M. D.
Dept. of Internal Medicine · University of Milan · Gastroenterology and Gastrointestinal Endoscopy Service · IRCCS Ospedale Maggiore Policlinico
Via Pace 9 · 20122 Milano · Italy ·
Fax: +39 02 5032 0747