Kardiologie up2date, Table of Contents Kardiologie up2date 2006; 2(2): 119-126DOI: 10.1055/s-2006-944532 Hotline - Herzrhythmusstörungen © Georg Thieme Verlag Stuttgart · New York Mögliche Störungen von Herzschrittmachern und implantierten Defibrillatoren Christof Kolb, Claus Schmitt Recommend Article Abstract Buy Article All articles of this category Full Text References Literatur 1 Kolb C, Wille B, Maurer D. et al . Avoidance of inappropriate mode switch due to far-field R-wave sensing in dual chamber pacemakers - final results of the FFS-test-study. Eur Heart J. 2005; P1177 (Suppl.) 2 Cools F JC, VanTwembeke R RC, Backers J, Verpooten G A. Stability of far field R wave signals in different conditions. Europace. 2003; 5 175-183 3 Kolb C, Aratma S, Zrenner B, Schmitt C. Preventricular far-field sensing in the atrial channel of dual chamber pacemakers - an occasional cause of inappropriate mode switch. J Interv Card Electrophysiol. 2004; 10 231-235 4 Willems R, Holemans P, Ector H, Van De Werf F, Heidbüchel H. Paradoxical undersensing at a high sensitivity in dual chamber pacemakers. Pacing Clin Electrophysiol. 2001; 24 308-315 5 Kolb C, Halbfaß P, Zrenner B, Schmitt C. Paradoxical atrial undersensing due to inappropriate atrial noise reversion of atrial fibrillation in dual chamber pacemakers. J Cardiovasc Electrophysiol. 2005; 16 696-700 6 Kolb C, Zrenner B, Schreieck J, Schmitt C. Strategies to avoid inappropriate therapies due to ventricular double detection in biventricular pacing implantable cardioverter defibrillators. Eur J Heart Fail. 2003; 5 523-526 7 Kolb C, Markwardt C, Zrenner B, Schmitt C. Pacemaker auto-interference by thoracic impedance measurement for the rate response function. Pacing Clin Electrophysiol. 2005; 28 1360-1362 8 Kolb C, Zrenner B, Schmitt C. Incidence of electromagnetic interference in implantable cardioverter defibrillators. Pacing Clin Electrophysiol. 2001; 24 465-468 9 Kolb C, Deisenhofer I, Weyerbrock S. et al . Incidence of antitachycardia therapy suspension due to magnet reversion in implantable cardioverter defibrillators. Pacing Clin Electrophysiol. 2004; 27 221-223 10 Naegeli B, Osswald S, Deola M, Burkart F. Intermittent pacemaker dysfunction caused by digital mobile telephones. J Am Coll Cardiol. 1996; 27 1471-1477 11 Hayes D L, Wang P J, Reynolds D W. et al . Interference with cardiac pacemakers by cellular telephones. N Engl J Med. 1997; 336 1473-1479 12 Altamura G, Toscano S, Gentilucci G. et al . Influence of digital and analogue cellular telephones on implanted pacemakers. Eur Heart J. 1997; 18 1632-1641 13 Kolb C, Schmieder S, Lehmann G. et al . Do airport metal detectors interfere with implantable pacemakers or cardioverter defibrillators?. J Am Coll Cardiol. 2003; 41 2054-2059 14 Dawson T W, Caputa K, Stuchly M A. et al . Pacemaker interference by magnetic fields at power line frequencies. IEEE Trans Biomed Eng. 2002; 49 254-262 15 Scholten A, Sily J. The interference threshold of unipolar cardiac pacemakers in extremely low frequency magnetic fields. J Med Eng Technol. 2001; 25 185-194 16 Crevenna R, Stix G, Pleiner J. et al . Electromagnetic interference by transcutaneous neuromuscular electrical stimulation in patients with bipolar sensing implantable cardioverter defibrillators: a pilot safety study. Pacing Clin Electrophysiol. 2003; 26 626-629 Dr. med. Christof Kolb Deutsches Herzzentrum München Lazarettstr. 36 · 80636 München Phone: 089 1218-2020 Fax: 089 1218-4593 Email: kolb@dhm.mhn.de