J Reconstr Microsurg 2006; 22(8): 625-630
DOI: 10.1055/s-2006-956236
TECHNICAL INNOVATION

Copyright © 2006 by Thieme Medical Publishers, Inc., 333 Seventh Avenue, New York, NY 10001, USA.

New Microvenous Anastomosis Model for Microsurgical Training: External Jugular Vein

Serdar Nasir1 , Mustafa Asim Aydin1 , Nermin Karahan2 , Deniz Demiryürek3 , Mustafa Sargon3
  • 1Department of Plastic and Reconstructive Surgery, Süleyman Demirel University School of Medicine, Isparta, Turkey
  • 2Department of Pathology, Süleyman Demirel University School of Medicine, Isparta, Turkey
  • 3Department of Anatomy, Hacettepe University, Faculty of Medicine, Ankara, Turkey
Further Information

Publication History

Accepted: April 18, 2006

Publication Date:
30 November 2006 (online)

ABSTRACT

In microsurgical training, the femoral vein is used frequently for a microvenous anastomosis model. But the femoral vein in the rat does not completely simulate the human vein because of its thin wall, fragility, and tendency to collapse. These anatomic characteristics cause some difficulty in carrying out anastomoses in microsurgery training particularly for beginners. The authors propose the external jugular vein of the rat for microsurgical training in microvenous anastomoses. In 10 Wistar rats, the anatomy of the external jugular vein was studied by dissection and histology. Anatomic dissections demonstrate that the external jugular vein has an average diameter of 1.9 mm (range: 1.6 to 2.1 mm) without tendency to collapse. The vein is easily dissected without any accompanying anatomic structure for an average segment of 45 mm, allowing effortless approximator clamp placement.

Comparison of its cross section with that of the femoral vein and other previously described models by light microscopy and scanning electron microscopy reveals a larger diameter and much thicker vessel wall with a prominent tunica media and adventitia. Based on the anatomic findings in 20 rats, the external jugular vein was anastomosed with end-to-end standard microsurgical technique using 8-0 (n = 10) and 10-0 (n = 10) nylon sutures. Results indicate a 100 percent patency rate immediately after the anastomosis for the two subgroups and 100 percent and 90 percent patency rates 1 week after the procedure for the 10-0 and 8-0 nylon suture groups, respectively. This model presents some advantages: the vein is easily dissected with the naked eye without using the operating microscope because it is the largest vein among the superficially located veins in the rat, and has a thick vessel wall without tendency to collapse. The operative area allows for training inbilateral microsurgical anastomoses using a single skin incision and is safe from autocannibalization. The model simulates clinical microvenous anastomosis better because of its similarities to human large diameter flap veins.

REFERENCES

  • 1 Blain B, Zhang F, Jones M et al.. Vascular grafts in the rat model: an anatomic study.  Microsurgery. 2001;  21 80-83
  • 2 Van Bemmelen S P, van Papendrecht A H, Nieuborg L. Evaluation of the patency of microvenous anastomoses by phlebography after intramedullary injection of contrast material.  Br J Plast Surg. 1983;  36 463-465
  • 3 Zhang L, Kolker A R, Choe E I, Bakshandeh N, Josephson G, Wu F C, Siebert J W, Kasabian A K. Venous microanastomosis with the Unilink system, sleeve, and suture techniques:a comparative study in the rat.  J Reconstr Microsurg. 1997;  13 257-261 discussion 261-262
  • 4 Hui K C, Zhang F, Shaw W W, Taylor A, Komorowska-Timek E, Lineaweaver W C. Assessment of the patency of microvascular venous anastomosis.  J Reconstr Microsurg. 2002;  18 111-114
  • 5 Akyurek M, Safak T, Oztekin C, Sargon M, Kecik A. Dorsal penile vein as a new training model for microvenous anastomosis in rats.  Ann Plast Surg. 2002;  49 280-284
  • 6 Akan M, Cakir B, Akoz T. Increasing vessel diameter with the open Y technique for diameter discrepancy.  J Reconstr Microsurg. 2004;  20 651-657
  • 7 Karamursel S, Kayikcioglu A, Safak T, Kecik A. End-to-side microvascular anastomosis using an external metal ring.  Br J Plast Surg. 2000;  53 423-426
  • 8 Iwasa H, Sato F, Shimabukuro H, Yamada N, Ikada Y, Hyon S H. One-knot microvascular anastomosis. An experimental study in rats.  J Neurosurg. 1987;  66 764-767

 Dr.
Serdar NasirM.D. 

Belmaş evleri 7067 ada A blok daire: 3 Batikent