Subscribe to RSS
Please copy the URL and add it into your RSS Feed Reader.
https://www.thieme-connect.de/rss/thieme/en/10.1055-s-00000011.xml
Dtsch Med Wochenschr 2007; 132: e69-e73
DOI: 10.1055/s-2007-959047
DOI: 10.1055/s-2007-959047
Statistik | Statistics
© Georg Thieme Verlag KG Stuttgart · New York
Vergleich von Messmethoden
- Artikel Nr. 24 der Statistik-Serie in der DMW -Comparing methods of measurementFurther Information
Publication History
Publication Date:
25 May 2007 (online)
Schlüsselwörter
Messmethoden - Bland-Altman-Methode - Intraklass-Korrelationsoeffizient - Wiederholbarkeit
Key words
Methods of measurement - Bland-Altman method - Intraclass correlation coefficient (ICC) - Repeatability
Literatur
- 1 Grouven U, Bender R, Ziegler A, Lange S. Der Kappa-Koeffizient. Dtsch Med Wochenschr. 2007; 132 e65-e68
- 2 Bland J M, Altman D G. Measuring agreement in method comparison studies. Stat Meth Med Res. 1999; 8 135-160
- 3 Lin L I. A concordance correlation coefficient to evaluate reproducibility. Biometrics. 1989; 45 255-268
- 4 Atkinson G, Nevill A. Comment on the use of concordance correlation to assess the agreement between two variables. Biometrics. 1997; 53 775-777
- 5 Bland J M, Altman D G. Applying the right statistics: analyses of measurement studies. Ultrasound Obstet Gynecol. 2003; 22 85-93
- 6 Müller R, Büttner P. A critical discussion of intraclass correlation coefficients. Stat Med. 1994; 13 2465-2476
- 7 Bland J M, Altman D G. A note on the use of the intraclass correlation coefficient in the evaluation of agreement between two methods of measurement. Comput Biol Med. 1990; 20 337-340
- 8 Bartko J J. Measures of agreement: a single procedure. Stat Med. 1994; 13 737-745
- 9 Fleiss J L, Levin B, Paik M C. Statistical Methods for Rates and Proportions. Third edition. Wiley 2003
- 10 Bland J M, Altman D G. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986; i 307-310
- 11 Bland J M, Altman D G. Comparing methods of measurement: why plotting difference against standard method is misleading. Lancet. 1995; 346 1085-1087
- 12 Bahmaie A, Hughes S W, Clark T. et al . Serial fetal lung volume measurement using three-dimensional ultrasound. Ultrasound Obstet Gynecol. 2000; 16 154-158
- 13 Ryan T P, Woodall W H. The most-cited statistical papers. J Appl Stat. 2005; 32 461-474
Privatdozent Dr. rer. biol. hum. Ralf Bender
Institut für Qualität und Wirtschaftlichkeit im Gesundheitswesen (IQWiG)
Dillenburger Straße 27
51105 Köln
Email: Ralf.Bender@iqwig.de