Background and study aims: Although capsule endoscopy has become a central diagnostic tool for small-bowel evaluation, retention of a capsule remains a major concern. This study attempted to investigate the incidence and clinical outcomes of capsule retention, and to determine the factors predictive of spontaneous capsule passage after retention.
Patients and methods: Through a nationwide multicenter survey, we retrospectively reviewed the records of 1291 patients who had a capsule endoscopy between February 2002 and July 2006 in Korea. Clinical and procedural characteristics and postprocedural outcomes were analyzed for the cases with capsule retention.
Results: Capsule retention occurred in 2.5 % of total cases (32/1291). The major diseases accompanying capsule retention were Crohn’s disease, malignant tumors, and tuberculous enterocolitis, in decreasing order. In 11 of the 32 patients (34.4 %), early surgical or endoscopic interventions were instituted for diagnosis or treatment of diseases before retention symptoms developed. The remaining 21 (65.6 %) patients initially received medical treatments. Of these, 10 (31.3 %) ultimately underwent surgical intervention due to the development of symptoms of intestinal obstruction or medical treatment failure. The other 11 (34.4 %) eventually passed the capsule. The presence of a larger lumen diameter (greater than two-thirds of the capsule diameter) at the stricture site was associated with spontaneous passage.
Conclusions: Our large-scale study suggests that retention occurs infrequently during capsule endoscopy. Moreover, a retained capsule might indicate the best intervention for the offending pathology, or it may spontaneously pass in the long run, particularly in patients with less small bowel stricture.
References
1
Swain P, Adler D, Enns R.
Capsule endoscopy in obscure intestinal bleeding.
Endoscopy.
2005;
37
655-659
2
Scapa E, Jacob H, Lewkowicz S. et al .
Initial experience of wireless-capsule endoscopy for evaluating occult gastrointestinal bleeding and suspected small bowel pathology.
Am J Gastroenterol.
2002;
97
2776-2779
3
Fireman Z, Mahajna E, Broide E. et al .
Diagnosing small bowel Crohn’s disease with wireless capsule endoscopy.
Gut.
2003;
52
390-392
4
Shim K N, Kim Y S, Kim K J. et al .
Abdominal pain accompanied by weight loss may increase the diagnostic yield of capsule endoscopy: a Korean multicenter study.
Scand J Gastroenterol.
2006;
41
983-988
5
Fry L C, Carey E J, Shiff A D. et al .
The yield of capsule endoscopy in patients with abdominal pain or diarrhea.
Endoscopy.
2006;
38
498-502
6
Cave D, Legnani P, de Franchis R. et al .
ICCE consensus for capsule retention.
Endoscopy.
2005;
37
1065-1067
7
Pennazio M, Santucci R, Rondonotti E. et al .
Outcome of patients with obscure gastrointestinal bleeding after capsule endoscopy: report of 100 consecutive cases.
Gastroenterology.
2004;
126
643-653
8
Buchman A L, Miller F H, Wallin A. et al .
Videocapsule endoscopy versus barium contrast studies for the diagnosis of Crohn’s disease recurrence involving the small intestine.
Am J Gastroenterol.
2004;
99
2171-2177
9
Cheifetz A S, Kornbluth A A, Legnani P. et al .
The risk of retention of the capsule endoscope in patients with known or suspected Crohn’s disease.
Am J Gastroenterol.
2006;
101
2218-2222
10
Cheifetz A S, Lewis B S.
Capsule endoscopy retention: is it a complication?.
J Clin Gastroenterol.
2006;
40
688-691
11
Baichi M M, Arifuddin R M, Mantry P S.
What we have learned from 5 cases of permanent capsule retention.
Gastrointest Endosc.
2006;
64
283-287
12
Rondonotti E, Herrerias J M, Pennazio M, Caunedo A, Mascarenhas-Saraiva M, de Franchis R.
Complications, limitations, and failures of capsule endoscopy: a review of 733 cases.
Gastrointest Endosc.
2005;
62
712-716
13
Lewis B.
How to prevent endoscopic capsule retention.
Endoscopy.
2005;
37
852-856
14
Sears D M, Avots-Avotins A, Culp K, Gavin M W.
Frequency and clinical outcome of capsule retention during capsule endoscopy for GI bleeding of obscure origin.
Gastrointest Endosc.
2004;
60
822-827
15
Yang S K, Loftus E V, Sandborn W J.
Epidemiology of inflammatory bowel disease in Asia.
Inflamm Bowel Dis.
2001;
7
260-270
16
Kim S G, Kim J S, Jung H C, Song I S.
Is a 9-month treatment sufficient in tuberculous enterocolitis? A prospective, randomized, single-centre study.
Aliment Pharmacol Ther.
2003;
18
85-91
17
Tandon H D, Prakash A.
Pathology of intestinal tuberculosis and its distinction from Crohn’s disease.
Gut.
1972;
13
260-269
18
Barkin J S, Friedman S.
Wireless capsule endoscopy requiring surgical intervention. The world’s experience.
Am J Gastroenterol.
2002;
97
83
19
Aberra F N, Lewis J D, Hass D, Rombeau J L, Osborne B, Lichtenstein G R.
Corticosteroids and immunomodulators: postoperative infectious complication risk in inflammatory bowel disease patients.
Gastroenterology.
2003;
125
320-327
20
Subramanian V, Pollok R C, Kang J Y, Kumar D.
Systematic review of postoperative complications in patients with inflammatory bowel disease treated with immunomodulators.
Br J Surg.
2006;
93
793-799
21
Spada C, Spera G, Riccioni M. et al .
A novel diagnostic tool for detecting functional patency of the small bowel: the Given patency capsule.
Endoscopy.
2005;
37
793-800
22
Boivin M L, Lochs H, Voderholzer W A.
Does passage of a patency capsule indicate small-bowel patency? A prospective clinical trial.
Endoscopy.
2005;
37
808-815
23
Signorelli C, Rondonotti E, Villa F. et al .
Use of the Given patency system for the screening of patients at high risk for capsule retention.
Dig Liver Dis.
2006;
38
326-330
24
Voderholzer W A, Beinhoelzl J, Rogalla P. et al .
Small bowel involvement in Crohn’s disease: a prospective comparison of wireless capsule endoscopy and computed tomography enteroclysis.
Gut.
2005;
54
369-373
D. K. Chang, MD, PhD
Division of Gastroenterology Department of Medicine Sungkyunkwan University School of Medicine Samsung Medical Center
50 Irwon-dong Gangnam-gu Seoul 135-710 Korea
Fax: +82-2-34103849
Email: dkchang@skku.edu