Cent Eur Neurosurg 2007; 68(2): 50-58
DOI: 10.1055/s-2007-980171
Original Article

© Georg Thieme Verlag KG Stuttgart · New York

Posterior Instrumentation of the Cervical Spine with a Versatile Modular Fixation System

Dorsale Instrumentation der Halswirbelsäule mit einem vielseitigen, modularen StabilisierungssystemM. Stoffel 1 , 2 , M. Behr 2 , F. Ringel 1 , 2 , C. Stuer 1 , 2 , B. Meyer 1
  • 1Department of Neurosurgery, Klinikum rechts der Isar, Technische Universität, München, Germany
  • 2Department of Neurosurgery, Rheinische Friedrich-Wilhelms Universität, Bonn, Germany
Further Information

Publication History

Publication Date:
06 July 2007 (online)

Abstract

Object: To study the feasibility/suitability of posterior instrumentation of the entire cervical and upper thoracic spine (C0-Th5) for a broad spectrum of indications in a predominantly old-aged and co-morbid patient population using a novel occipito-cervico-thoracic system.

Methods: 54 consecutive patients (m=31, f=23, median age 63) with degenerative, neoplastic, traumatic, or infectious diseases were treated over a period of 29 months. Primary posterior as well as secondary posterior approaches after anterior instrumentation were used. Clinical and radiographic data was acquired prospectively using standard scales at pre-defined time intervals.

Results: On average 3 segments (range: 1-6) were bridged without significant intraoperative complications. In 30 cases a posterior decompression was additionally performed. Nine of 315 implanted screws were defined as suboptimal, leading to operative revision in 5 cases. During the follow-up interval (9±1.1 months, range: 3-25) patients showed a statistically significant improved mobility (Karnofsky score: 58±3 [pre] compared to 75±3 [post]) with improved mental and physical health (SF-36 health survey: mental component 44 [pre] to 51 [post], physical component 34 [pre] to 44 [post]) and less subjective pain (VAS: 3.9±0.3 [pre] to 0.5±0.1 [post]). All patients remained neurologically stable or improved after operation except two, who transiently deteriorated by one Nurick grade. Only one dislocation and no breakages of the implanted hardware were seen, and no significant secondary loss of spinal alignment was observed.

Conclusions: Posterior instrumentation of the entire cervical and upper thoracic spine with the novel occipito-cervico-thoracic system has been shown to be safe, convenient and effective. The anterior approach in high-risk patients can thus be avoided, and the approach provides substantial additional stability to multi-level anterior constructs.

Zusammenfassung

Studienziel: Die Eignung/Durchführbarkeit der dorsalen Stabilisierung der gesamten zervikalen und oberen thorakalen Wirbelsäule (C0-Th5) für ein breites Indikationsspektrum in einem vorwiegend älteren und komorbiden Patientenkollektiv mit Hilfe eines modernen okzipito-zerviko-thorakalen Systems zu untersuchen.

Patienten und Methoden: 54 konsekutive Patienten (m=31, w=23, Altersmedian 63) mit degenerativen, neoplastischen, traumatischen oder infektiösen Erkrankungen wurden in einem Zeitraum von 29 Monaten operativ behandelt. Dabei wurden sowohl primär dorsale, als auch sekundär dorsale Vorgehensweisen nach ventraler Instrumentation verwendet. Die Patienten wurden in vordefinierten Zeitintervallen klinisch und radiografisch anhand von Standardskalen prospektiv beurteilt.

Ergebnisse: Durchschnittlich wurden 3 Bewegungssegmente (1-6) überbrückt ohne signifikante intraoperative Komplikationen. In 30 Fällen wurde zusätzlich eine dorsale Dekompression durchgeführt. 9 von 315 implantierten Schrauben wurden als suboptimal definiert, was in 5 Fällen zu einer operativen Revision führte. Während des Follow-ups (9±1.1 Monate, 3-25) verbesserte sich Mobilität (Karnofsky: 58±3 (prä), 75±3 (post)), mentale und physische Gesundheit (SF-36: mentale Komponente 44 (prä), 51 (post), physische Komponente 34 (prä), 44 (post)) sowie der selbst beurteilte Schmerz (VAS: 3.9±0.3 (prä), 0.5±0.1 (post)) der Patienten statistisch signifikant. Bis auf 2 Patienten, die sich vorübergehend um einen Nurick Grad verschlechterten, blieben alle Patienten neurologisch stabil oder verbesserten sich nach der Operation. Es wurden kein Bruch und nur eine Dislokation des implantierten Materials beobachtet und kein signifikanter sekundärer Verlust des spinalen Alignments.

Schlussfolgerung: Die dorsale Instrumentation der zervikalen und oberen thorakalen Wirbelsäule mit dem modernen okzipito-zerviko-thorakalen System hat sich als sicher, bequem und effektiv herausgestellt. Somit kann - wenn nötig - ein ventrales Vorgehen in Hochrisikopatienten vermieden werden bzw. einem multisegmentalen ventralen Konstrukt wesentliche zusätzliche Stabilität verliehen werden.

References

  • 1 Abumi K, Takada T, Shono Y, Kaneda K, Fujiya M. Posterior occipitocervical reconstruction using cervical pedicle screws and plate-rod systems.  Spine. 1999;  24 1425-1434
  • 2 Barrey C, Mertens P, Rumelhart C, Cotton F, Jund J, Perrin G. Biomechanical evaluation of cervical lateral mass fixation: a comparison of the Roy-Camille and Magerl screw techniques.  J Neurosurg. 2004;  100 268-276
  • 3 Bohler J. Anterior stabilization for acute fractures and non-unions of the dens.  J Bone Joint Surg Am. 1982;  64 18-27
  • 4 Bose B. Anterior cervical arthrodesis using DOC dynamic stabilization implant for improvement in sagittal angulation and controlled settling.  J Neurosurg. 2003;  98 8-13
  • 5 Callahan RA, Johnson RM, Margolis RN, Keggi KJ, Albright JA, Southwick WO. Cervical facet fusion for control of instability following laminectomy.  J Bone Joint Surg Am. 1977;  59 991-1002
  • 6 Cloward RB. Lesions of the intervertebral disks and their treatment by interbody fusion methods.  The painful disk. Clin Orthop. 1963;  27 51-77
  • 7 Cusick JF, Pintar FA, Yoganandan N. Biomechanical alterations induced by multilevel cervical laminectomy.  Spine. 1995;  20 2392-2398 , discussion 2398-2399
  • 8 Dickman CA, Sonntag VK, Papadopoulos SM, Hadley MN. The interspinous method of posterior atlantoaxial arthrodesis.  J Neurosurg. 1991;  74 190-198
  • 9 Emery SE, Bohlman HH, Bolesta MJ, Jones PK. Anterior cervical decompression and arthrodesis for the treatment of cervical spondylotic myelopathy. Two to seventeen-year follow-up.  J Bone Joint Surg Am. 1998;  80 941-951
  • 10 Grob D, Dvorak J, Gschwend N, Froehlich M. Posterior occipito-cervical fusion in rheumatoid arthritis.  Arch Orthop Trauma Surg. 1990;  110 38-44
  • 11 Heller JG, Estes BT, Zaouali M, Diop A. Biomechanical study of screws in the lateral masses: variables affecting pull-out resistance.  J Bone Joint Surg Am. 1996;  78 1315-1321
  • 12 Hitchon PW, Brenton MD, Coppes JK, From AM, Torner JC. Factors affecting the pullout strength of self-drilling and self-tapping anterior cervical screws.  Spine. 2003;  28 9-13
  • 13 Huch K, Cakir B, Dreinhofer K, Puhl W, Richter M. A new dorsal modular fixation device allows a modified approach in cervical and cervico-thoracic neoplastic lesions.  Eur Spine J. 2004;  13 222-228
  • 14 Jeanneret B. Posterior rod system of the cervical spine: a new implant allowing optimal screw insertion.  Eur Spine J. 1996;  5 350-356
  • 15 Kotani Y, Cunningham BW, Abumi K, MacAfee PC. Biomechanical analysis of cervical stabilization systems. An assessment of transpedicular screw fixation in the cervical spine.  Spine. 1994;  19 2529-2539
  • 16 Lim TH, An HS, Evanich C, Hasanoglu KY, MacGrady L, Wilson CR. Strength of anterior vertebral screw fixation in relationship to bone mineral density.  J Spinal Disord. 1995;  8 121-125
  • 17 Nurick S. The natural history and the results of surgical treatment of the spinal cord disorder associated with cervical spondylosis.  Brain. 1972;  95 101-108
  • 18 Olerud C, Lind B, Sahlstedt B. The Olerud Cervical Fixation System; a study of safety and efficacy.  Ups J Med Sci. 1999;  104 131-143
  • 19 Perry J, Nickel VL. Total cervicalspine fusion for neck paralysis.  J Bone Joint Surg Am. 1959;  41-A 37-60
  • 20 Richter M, Wilke HJ, Kluger P, Neller S, Claes L, Puhl W. Biomechanical evaluation of a new modular rod-screw implant system for posterior instrumentation of the occipito-cervical spine: in-vitro comparison with two established implant systems.  Eur Spine J. 2000;  9 417-425
  • 21 Richter M. Posterior instrumentation of the cervical spine for instability using the “Neon occipito-cervical system”. Part 1: Atlanto-axial instrumentation.  Operat Orthop Traumatol. 2003;  15 70-89
  • 22 Roy-Camille R, Garcon P, Begue TH. et al . Etude bioméchanique de l'ancrage des vis pédiculaires dorsales et lombaires.  Rachis. 1991;  3 109-114
  • 23 Singh K, Vaccaro AR, Kim J, Lorenz EP, Lim TH, An HS. Biomechanical comparison of cervical spine reconstructive techniques after a multilevel corpectomy of the cervical spine.  Spine. 2003;  28 2352-2358 , discussion 2358
  • 24 Smith MD, Anderson P, Grady MS. Occipitocervical arthrodesis using contoured plate fixation. An early report on a versatile fixation technique.  Spine. 1993;  18 1984-1990
  • 25 Sonntag VK, Kalfas I. Innovative cervical fusion and instrumentation techniques.  Clin Neurosurg. 1991;  37 636-660
  • 26 Tye GW, Graham RS, Broaddus WC, Young HF. Graft subsidence after instrument-assisted anterior cervical fusion.  J Neurosurg. 2002;  97 186-192
  • 27 Wertheim SB, Bohlman HH. Occipitocervical fusion. Indications, technique, and long-term results in thirteen patients.  J Bone Joint Surg Am. 1987;  69 833-836
  • 28 Yonenobu K, Hosono N, Iwasaki M, Asano M, Ono K. Laminoplasty versus subtotal corpectomy. A comparative study of results in multisegmental cervical spondylotic myelopathy.  Spine. 1992;  17 1281-1284

Correspondence

Dr. M. Stoffel

Department of Neurosurgery

Technische Universität

Ismaningerstr. 22

München

81675 Bayern

Germany

Phone: +49/89/4140 21 54

Fax: +49/89/4140 48 89

Email: michael.stoffel@lrz.tu-muenchen.de